6 research outputs found
Resuming Training in High-Level Athletes After Mild COVID-19 Infection: A Multicenter Prospective Study (ASCCOVID-19)
BACKGROUND: There is a paucity of data on cardiovascular sequelae of asymptomatic/mildly symptomatic SARS-Cov-2 infections (COVID). OBJECTIVES: The aim of this prospective study was to characterize the cardiovascular sequelae of asymptomatic/mildly symptomatic COVID-19 among high/elite-level athletes. METHODS: 950 athletes (779 professional French National Rugby League (F-NRL) players; 171 student athletes) were included. SARS-Cov-2 testing was performed at inclusion, and F-NRL athletes were intensely followed-up for incident COVID-19. Athletes underwent ECG and biomarker profiling (D-Dimer, troponin, C-reactive protein). COVID(+) athletes underwent additional exercise testing, echocardiography and cardiac magnetic resonance imaging (CMR). RESULTS: 285/950 athletes (30.0%) had mild/asymptomatic COVID-19 [79 (8.3%) at inclusion (COVID(+)(prevalent)); 206 (28.3%) during follow-up (COVID(+)(incident))]. 2.6% COVID(+) athletes had abnormal ECGs, while 0.4% had an abnormal echocardiogram. During stress testing (following 7-day rest), COVID(+) athletes had a functional capacity of 12.8 ± 2.7 METS with only stress-induced premature ventricular ectopy in 10 (4.3%). Prevalence of CMR scar was comparable between COVID(+) athletes and controls [COVID(+) vs. COVID(-); 1/102 (1.0%) vs 1/28 (3.6%)]. During 289 ± 56 days follow-up, one athlete had ventricular tachycardia, with no obvious link with a SARS-CoV-2 infection. The proportion with troponin I and CRP values above the upper-limit threshold was comparable between pre- and post-infection (5.9% vs 5.9%, and 5.6% vs 8.7%, respectively). The proportion with D-Dimer values above the upper-limit threshold increased when comparing pre- and post-infection (7.9% vs 17.3%, P = 0.01). CONCLUSION: The absence of cardiac sequelae in pauci/asymptomatic COVID(+) athletes is reassuring and argues against the need for systematic cardiac assessment prior to resumption of training (clinicaltrials.gov; NCT04936503).L'Institut de Rythmologie et modélisation Cardiaqu
From the Reference SEU Monitor to the Technology Demonstration Module On-Board PROBA-II
The reference SEU Monitor system designed and presented in 2005 (R. H. Sorensen, F.-X. Guerre, and A. Roseng "Design, testing and calibration of a reference SEU monitor system," in Proc. RADECS, 2005, pp. B3-1-B3-7) has now been used by many researchers at many radiation test sites and has provided valuable calibration data in support of numerous projects. As some of these findings and results give new insight into improved inter-facility calibrations and provide additional inputs into ongoing SEE research, a few of the more interesting cases are presented. Furthermore the 'detector element', the Atmel AT60142F SRAM, now in a hybrid configuration, will form the key detector element in the Technology Demonstration Module (TDM) to be flown on-board the PROBA-II satellite, to be launched at the beginning of 2009. This flight opportunity extends the Reference SEU Database with both ground and space data, taken on the same device under identical operating conditions. Additionally, the Reference SEU Monitor concept is employed as the basis for the new Reference SEL Monitor system, currently under characterization and preparation for integration on the TDM. Ground SEU/SEL characterization of this latch-up experiment is also presented as well as the basic concept of the TDM, the PROBA-II Radiation Monitor module
Lancet
Background Cataract surgery is one of the most common operations in health care. Femtosecond laser-assisted cataract surgery (FLACS) enables more precise ocular incisions and lens fragmentation than does phacoemulsification cataract surgery (PCS). We hypothesised that FLACS might improve outcomes in cataract surgery compared with PCS despite having higher costs. Methods We did a participant-masked randomised superiority clinical trial comparing FLACS and PCS in two parallel groups (permuted block randomisation stratified on centres via a centralised web-based application, allocation ratio 1:1, block size of 2 or 4 for unilateral cases and 2 or 6 for bilateral cases). Five French University Hospitals enrolled consecutive patients aged 22 years or older who were eligible for unilateral or bilateral cataract surgery. Participants, outcome assessors, and technicians carrying out examinations were masked to the surgical treatment allocation until the last follow-up visit and a sham laser procedure was set up for participants randomly assigned to the PCS arm. The primary clinical endpoint was the success rate of surgery, defined as a composite of four outcomes at a 3-month postoperative visit: absence of severe perioperative complication, a best-corrected visual acuity (BCVA) of 0·0 LogMAR (logarithm of the minimum angle of resolution) or better, an absolute refractive error of 0·75 dioptres or less, and unchanged postoperative corneal astigmatism power (≤0·5 dioptres) and axis (≤20°). The primary economic endpoint was the incremental cost per additional patient who had treatment success at 3 months. Primary outcomes were assessed in all randomly assigned patients who met all eligibility criteria (missing data considered as failure). We used mixed logistic regression models or mixed linear regression models for statistical comparisons, adjusted on centres and whether cataract surgery was bilateral or unilateral. The study is registered with ClinicalTrials.gov, NCT01982006. Findings Of the 907 patients (1476 eyes) randomly assigned between Oct 9, 2013, and Oct 30, 2015, 870 (704 eyes in FLACS group and 685 eyes in the PCS group) were analysed. We identified no significant difference in the success rate of surgery between the FLACS and PCS groups (FLACS: 41·1% [289 eyes]; PCS: 43·6% [299 eyes]); adjusted odds ratio 0·85, 95% CI 0·64–1·12, p=0·250). The incremental cost-effectiveness ratio was €10 703 saved per additional patient who had treatment success with PCS compared with FLACS. We observed no severe adverse events during the femtosecond laser procedure, and most of the complications in the FLACS group related to the primary outcome measures occurred during the phacoemulsification phase or postoperatively. Interpretation Despite its advanced technology, femtosecond laser was not superior to phacoemulsification in cataract surgery and, with higher costs, did not provide an additional benefit over phacoemulsification for patients or health-care systems. Funding French Ministry of Social Affairs and Health