35 research outputs found

    Convulsive liability of bupropion hydrochloride metabolites in Swiss albino mice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>It is known that following chronic dosing with bupropion HCl active metabolites are present in plasma at levels that are several times higher than that of the parent drug, but the possible convulsive effects of the major metabolites are not known.</p> <p>Methods</p> <p>We investigated the convulsive liability and dose-response of the three major bupropion metabolites following intraperitoneal administration of single doses in female Swiss albino mice, namely erythrohydrobupropion HCl, threohydrobupropion HCl, and hydroxybupropion HCl. We compared these to bupropion HCl. The actual doses of the metabolites administered to mice (n = 120; 10 per dose group) were equimolar equivalents of bupropion HCl 25, 50 and 75 mg/kg. Post treatment, all animals were observed continuously for 2 h during which the number, time of onset, duration and intensity of convulsions were recorded. The primary outcome variable was the percentage of mice in each group who had a convulsion at each dose. Other outcome measures were the time to onset of convulsions, mean convulsions per mouse, and the duration and intensity of convulsions.</p> <p>Results</p> <p>All metabolites were associated with a greater percentage of seizures compared to bupropion, but the percentage of convulsions differed between metabolites. Hydroxybupropion HCl treatment induced the largest percentage of convulsing mice (100% at both 50 and 75 mg/kg) followed by threohydrobupropion HCl (50% and 100%), and then erythrohydrobupropion HCl (10% and 90%), compared to bupropion HCl (0% and 10%). Probit analysis also revealed the dose-response curves were significantly different (p < 0.0001) with CD<sub>50 </sub>values of 35, 50, 61 and 82 mg/kg, respectively for the four different treatments. Cox proportional hazards model results showed that bupropion HCl, erythrohydrobupropion HCl, and threohydrobupropion HCl were significantly less likely to induce convulsions within the 2-h post treatment observation period compared to hydroxybupropion HCl. The mean convulsions per mouse also showed the same dose-dependent and metabolite-dependent trends.</p> <p>Conclusion</p> <p>The demonstration of the dose-dependent and metabolite-dependent convulsive effects of bupropion metabolites is a novelty.</p

    Quality of Data Entry Using Single Entry, Double Entry and Automated Forms Processing–An Example Based on a Study of Patient-Reported Outcomes

    Get PDF
    Background: The clinical and scientific usage of patient-reported outcome measures is increasing in the health services. Often paper forms are used. Manual double entry of data is defined as the definitive gold standard for transferring data to an electronic format, but the process is laborious. Automated forms processing may be an alternative, but further validation is warranted. Methods: 200 patients were randomly selected from a cohort of 5777 patients who had previously answered two different questionnaires. The questionnaires were scanned using an automated forms processing technique, as well as processed by single and double manual data entry, using the EpiData Entry data entry program. The main outcome measure was the proportion of correctly entered numbers at question, form and study level. Results: Manual double-key data entry (error proportion per 1000 fields = 0.046 (95 % CI: 0.001–0.258)) performed better than single-key data entry (error proportion per 1000 fields = 0.370 (95 % CI: 0.160–0.729), (p = 0.020)). There was no statistical difference between Optical Mark Recognition (error proportion per 1000 fields = 0.046 (95 % CI: 0.001–0.258)) and double-key data entry (p = 1.000). With the Intelligent Character Recognition method, there was no statistical difference compared to single-key data entry (error proportion per 1000 fields = 6.734 (95 % CI: 0.817–24.113), (p = 0.656)), as well as double-key data entry (error proportion per 1000 fields = 3.367 (95 % CI: 0.085–18.616)), (p = 0.319))

    Precision mass measurement of 129-131Cd and their impact on stellar nucleosynthesis via the rapid neutron capture process

    No full text
    Masses adjacent to the classical waiting-point nuclide 130Cd have been measured by using the Penning- trap spectrometer ISOLTRAP at ISOLDE/CERN. We find a significant deviation of over 400 keV from earlier values evaluated by using nuclear beta-decay data. The new measurements show the reduction of the N = 82 shell gap below the doubly magic 132Sn. The nucleosynthesis associated with the ejected wind from type-II supernovae as well as from compact object binary mergers is studied, by using state-of-the-art hydrodynamic simulations. We find a consistent and direct impact of the newly measured masses on the calculated abundances in the A = 128–132 region and a reduction of the uncertainties from the precision mass input data.status: publishe

    Probing the N=32 Shell Closure below the Magic Proton Number Z=20: Mass Measurements of the Exotic Isotopes K-52,K-53

    No full text
    The recently confirmed neutron-shell closure at N=32 has been investigated for the first time below the magic proton number Z=20 with mass measurements of the exotic isotopes (52,53)K, the latter being the shortest-lived nuclide investigated at the online mass spectrometer ISOLTRAP. The resulting two-neutron separation energies reveal a 3 MeV shell gap at N=32, slightly lower than for 52Ca, highlighting the doubly magic nature of this nuclide. Skyrme-Hartree-Fock-Bogoliubov and ab initio Gorkov-Green function calculations are challenged by the new measurements but reproduce qualitatively the observed shell effect.status: publishe
    corecore