46 research outputs found

    Sternal plating for primary and secondary sternal closure; can it improve sternal stability?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sternal instability with mediastinitis is a very serious complication after median sternotomy. Biomechanical studies have suggested superiority of rigid plate fixation over wire cerclage for sternal fixation. This study tests the hypothesis that sternal closure stability can be improved by adding plate fixation in a human cadaver model.</p> <p>Methods</p> <p>Midline sternotomy was performed in 18 human cadavers. Four sternal closure techniques were tested: (1) approximation with six interrupted steel wires; (2) approximation with six interrupted cables; (3) closure 1 (wires) or 2 (cables) reinforced with a transverse sternal plate at the sixth rib; (4) Closure using 4 sternal plates alone. Intrathoracic pressure was increased in all techniques while sternal separation was measured by three pairs of sonomicrometry crystals fixed at the upper, middle and lower parts of the sternum until 2.0 mm separation was detected. Differences in displacement pressures were analyzed using repeated measures ANOVA and Regression Coefficients.</p> <p>Results</p> <p>Intrathoracic pressure required to cause 2.0 mm separation increased significantly from 183.3 ± 123.9 to 301.4 ± 204.5 in wires/cables alone vs. wires/cables plus one plate respectively, and to 355.0 ± 210.4 in the 4 plates group (p < 0.05). Regression Coefficients (95% CI) were 120 (47–194) and 142 (66–219) respectively for the plate groups.</p> <p>Conclusion</p> <p>Transverse sternal plating with 1 or 4 plates significantly improves sternal stability closure in human cadaver model. Adding a single sternal plate to primary closure improves the strength of sternal closure with traditional wiring potentially reducing the risk of sternal dehiscence and could be considered in high risk patients.</p

    Fatigue testing of three peristernal median sternotomy closure techniques

    Get PDF
    Failure of a sternotomy closure because of closure system fatigue is a complication that may result in dehiscence and put the individual at risk for serious complications. The purpose of this study was to assess the fatigue performance of three peristernal median sternotomy closure techniques (figure-of-eight stainless-steel wires, figure-of-eight stainless-steel cables, or Pectofix Dynamic Sternal Fixation [DSF] stainless-steel plates) in order to quantify the potential risk of fatigue failure of these devices when subject to cyclic loads in physiologically relevant loading directions

    Varying constants, Gravitation and Cosmology

    Get PDF
    Fundamental constants are a cornerstone of our physical laws. Any constant varying in space and/or time would reflect the existence of an almost massless field that couples to matter. This will induce a violation of the universality of free fall. It is thus of utmost importance for our understanding of gravity and of the domain of validity of general relativity to test for their constancy. We thus detail the relations between the constants, the tests of the local position invariance and of the universality of free fall. We then review the main experimental and observational constraints that have been obtained from atomic clocks, the Oklo phenomenon, Solar system observations, meteorites dating, quasar absorption spectra, stellar physics, pulsar timing, the cosmic microwave background and big bang nucleosynthesis. At each step we describe the basics of each system, its dependence with respect to the constants, the known systematic effects and the most recent constraints that have been obtained. We then describe the main theoretical frameworks in which the low-energy constants may actually be varying and we focus on the unification mechanisms and the relations between the variation of different constants. To finish, we discuss the more speculative possibility of understanding their numerical values and the apparent fine-tuning that they confront us with.Comment: 145 pages, 10 figures, Review for Living Reviews in Relativit

    Bending a beam by a generalized ideal elastomeric gel

    No full text
    corecore