26 research outputs found

    The influence of foot geometry on the calcaneal osteotomy angle based on two-dimensional static force analyses

    Get PDF
    Background: Malalignment of the hindfoot can be corrected with a calcaneal osteotomy (CO). A well-selected osteotomy angle in the sagittal plane will reduce the shear force in the osteotomy plane while walking. The purpose was to determine the presence of a relationship between the foot geometry and loading of the calcaneus, which influences the choice of the preferred CO angle. Methods A static free body force analysis was made of the posterior calcaneal fragment in the second half of the stance phase to determine the main loads: the plantar apeunorosis (PA) and Achilles tendon (AT). The third load is on the osteotomy surface which should be oriented such that the shear component of the force is zero. The force direction of the PA and AT was measured on 58 MRIs of the foot, and the force ratio between both structures was taken from the literature. In addition the PA-to-AT force ratio was estimated for different foot geometries to identify the relationship. Results: Based on the wish to minimize the shear force during walking, a mean CO angle was determined to be 33º (SD8) relative to the foot sole. In pes planus foot geometry, the angle should be higher than the mean. In pes cavus foot geometry, the angle should be smaller. Conclusion: Foot geometry, in particular the relative foot heights is a determinant for the individual angle in performing the sliding calcaneal osteotomy. It is recommended to take into account the foot geometry (arch) when deciding on the CO angle for hindfoot correction.Biomechanical EngineeringMechanical, Maritime and Materials Engineerin

    Nanoscale chemical analysis by tip-enhanced Raman spectroscopy

    No full text
    A fine metal tip brought to within a few nanometers of a molecular film is found to give strong enhancement of Raman scattered light from the sample. This new principle can be used for molecular analysis with excellent spatial resolution, only limited by the tip apex size and shape. No special sample preparation is required, and the enhancement is identical at every sample location, allowing for quantitative surface-enhanced Raman spectroscopy measurements. When scanning the tip over the sample surface. topographic information is obtained simultaneously and can be directly correlated with the spectroscopic data. (C) 2000 Elsevier Science B.V. All rights reserved

    Application of a shape-memory alloy internal fixator for treatment of acetabular fractures with a follow-up of two to nine years in China

    No full text
    Displaced acetabular fractures should be treated surgically. Over the past decade, surgical approaches to the acetabulum and the surgical technique for repair of common fracture patterns have advanced. Excellent outcomes after repair of these injuries can be achieved. The aim of this study was to assess the medium-term results of reconstruction of acetabular fractures by using shape-memory alloy designed by the authors. This is a retrospective review conducted at a level 1 trauma centre. From October 1999 to July 2009, 19 patients with acetabular fractures were treated with our patented Ni-Ti shape-memory alloy acetabular tridimensional memory alloy-fixation system (ATMFS). The ATMFS device was cooled with ice before implantation and then warmed to 40–50°C after implantation to produce balanced axial and compression forces that would stabilise the fracture three dimensionally. Our results are as follows; according to the D’Aubigne−Postel scoring system: Fifteen cases out of 19 (79%) achieved excellent or good clinical results. In two patients, late complications included avascular necrosis of the femoral head (ANFH) associated with posterior dislocation of the hip joint two years after the operation. We also observed two cases of grade II or III ectopic ossification, with good hip function, and one case of traumatic arthritis. In conclusion, these results demonstrate the effectiveness of the ATMFS device for the management of acetabular fracture. The device provides continuous compression of the fracture with minimal disruption to the local blood supply

    Tip-Enhanced Laser Ablation Sample Transfer for Biomolecule Mass Spectrometry

    No full text
    Atomic force microscope (AFM) tip enhanced laser ablation was used to transfer molecules from thin films to a suspended silver wire for off-line mass spectrometry using laser desorption ionization (LDI) and matrix-assisted laser desorption ionization (MALDI). An AFM with a 30 nm radius gold-coated silicon tip was used to image the sample and to hold the tip 15 nm from the surface for material removal using a 355 nm Nd:YAG laser. The ablated material was captured on a silver wire that was held 300 μ m vertically and 100 μm horizontally from the tip. For the small molecules anthracene and rhodamine 6G, the wire was cut and affixed to a metal target using double-sided conductive tape and analyzed by LDI using a commercial laser desorption time-of-flight mass spectrometer. Approximately 100 fg of material was ablated from each of the 1 μ m ablation spots and transferred with approximately 3% efficiency. For larger polypeptide molecules angiotensin II and bovine insulin, the captured material was dissolved in saturated matrix solution and deposited on a target for MALDI analysis
    corecore