226 research outputs found

    Development of specific PCR assays for the detection of Cryptocaryon irritans

    Get PDF
    Cryptocaryon irritans is one of the most important protozoan pathogens of marine fish, causing the “white spot” disease and posing a significant problem to marine aquaculture. In the present study, a C. irritans-specific reverse primer (S15) was designed based on the published sequence of the second internal transcribed spacer (ITS-2) of ribosomal DNA (rDNA) of C. irritans and used together with the conserved forward primer P1 to develop a specific polymerase chain reaction (PCR) assay for direct, rapid, and specific detection of C. irritans. The specificity of these primers was tested with both closely and distantly related ciliates (Pseudokeroronpsis rubra, Pseudokeroronpsis carnae, Euplotes sp. 1, Ichthyophthirius multifiliis, Pseudourostyla cristata, and Paramecium caudaium), and only C. irritans was detected and no product was amplified from any other ciliates examined in this study using the specific primer set P1-S15. The specific PCR assay was able to detect as low as 45 pg of C. irritans DNA and a nested PCR assay using two primer sets (P1/NC2, P1/S15) increased the sensitivity, allowing the detection of a single C. irritans. The species-specific PCR assays should provide useful tools for the diagnosis, prevention, and molecular epidemiological investigations of C. irritans infection in marine fish

    Mitochondrial DNA Copy Number Is Associated with Breast Cancer Risk

    Get PDF
    Mitochondrial DNA (mtDNA) copy number in peripheral blood is associated with increased risk of several cancers. However, data from prospective studies on mtDNA copy number and breast cancer risk are lacking. We evaluated the association between mtDNA copy number in peripheral blood and breast cancer risk in a nested case-control study of 183 breast cancer cases with pre-diagnostic blood samples and 529 individually matched controls among participants of the Singapore Chinese Health Study. The mtDNA copy number was measured using real time PCR. Conditional logistic regression analyses showed that there was an overall positive association between mtDNA copy number and breast cancer risk (Ptrend = 0.01). The elevated risk for higher mtDNA copy numbers was primarily seen for women with <3 years between blood draw and cancer diagnosis; ORs (95% CIs) for 2nd, 3rd, 4th, and 5th quintile of mtDNA copy number were 1.52 (0.61, 3.82), 2.52 (1.03, 6.12), 3.12 (1.31, 7.43), and 3.06 (1.25, 7.47), respectively, compared with the 1st quintile (Ptrend = 0.004). There was no association between mtDNA copy number and breast cancer risk among women who donated a blood sample ≥3 years before breast cancer diagnosis (Ptrend = 0.41). This study supports a prospective association between increased mtDNA copy number and breast cancer risk that is dependent on the time interval between blood collection and breast cancer diagnosis. Future studies are warranted to confirm these findings and to elucidate the biological role of mtDNA copy number in breast cancer risk. © 2013 Thyagarajan et al

    Survey of information technology in Intensive Care Units in Ontario, Canada

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Intensive Care Unit (ICU) is a data-rich environment where information technology (IT) may enhance patient care. We surveyed ICUs in the province of Ontario, Canada, to determine the availability, implementation and variability of information systems.</p> <p>Methods</p> <p>A self-administered internet-based survey was completed by ICU directors between May and October 2006. We measured the spectrum of ICU clinical data accessible electronically, the availability of decision support tools, the availability of electronic imaging systems for radiology, the use of electronic order entry and medication administration systems, and the availability of hardware and wireless or mobile systems. We used Fisher's Exact tests to compare IT availability and Classification and Regression Trees (CART) to estimate the optimal cut-point for the number of computers per ICU bed.</p> <p>Results</p> <p>We obtained responses from 50 hospitals (68.5% of institutions with level 3 ICUs), of which 21 (42%) were university-affiliated. The majority electronically accessed laboratory data and imaging reports (92%) and used picture archiving and communication systems (PACS) (76%). Other computing functions were less prevalent (medication administration records 46%, physician or nursing notes 26%; medication order entry 22%). No association was noted between IT availability and ICU size or university affiliation. Sites used clinical information systems from15 different vendors and 8 different PACS systems were in use. Half of the respondents described the number of computers available as insufficient. Wireless networks and mobile computing systems were used in 23 ICUs (46%).</p> <p>Conclusion</p> <p>Ontario ICUs demontrate a high prevalence of the use of basic information technology systems. However, implementation of the more complex and potentially more beneficial applications is low. The wide variation in vendors utilized may impair information exchange, interoperability and uniform data collection.</p

    Improving guideline adherence for cardiac rehabilitation in the Netherlands

    Get PDF
    Background In 2004, the Netherlands Society of Cardiology released the current guideline on cardiac rehabilitation. Given its complexity and the involvement of various healthcare disciplines, it was supplemented with a clinical algorithm, serving to facilitate its implementation in daily practice. Although the algorithm was shown to be effective for improving guideline adherence, several shortcomings and deficiencies were revealed. Based on these findings, the clinical algorithm has now been updated. This article describes the process and the changes that were made. Methods The revision consisted of three phases. First, the reliability of the measurement instruments included in the 2004 Clinical Algorithm was investigated by evaluating between-centre variations of the baseline assessment data. Second, based on the available evidence, a multidisciplinary expert advisory panel selected items needing revision and provided specific recommendations. Third, a guideline development group decided which revisions were finally included, also taking practical considerations into account. Results A total of nine items were revised: three because of new scientific insights and six because of the need for more objective measurement instruments. In all revised items, subjective assessment methods were replaced by more objective assessment tools (e.g. symptom-limited exercise instead of clinical judgement). In addition, four new key items were added: screening for anxiety/depression, stress, cardiovascular risk profile and alcohol consumption. Conclusion Based on previously determined shortcomings, the Clinical Algorithm for Cardiac Rehabilitation was thoroughly revised mainly by incorporating more objective assessment methods and by adding several new key area

    DeadEasy Mito-Glia: Automatic Counting of Mitotic Cells and Glial Cells in Drosophila

    Get PDF
    Cell number changes during normal development, and in disease (e.g., neurodegeneration, cancer). Many genes affect cell number, thus functional genetic analysis frequently requires analysis of cell number alterations upon loss of function mutations or in gain of function experiments. Drosophila is a most powerful model organism to investigate the function of genes involved in development or disease in vivo. Image processing and pattern recognition techniques can be used to extract information from microscopy images to quantify automatically distinct cellular features, but these methods are still not very extended in this model organism. Thus cellular quantification is often carried out manually, which is laborious, tedious, error prone or humanly unfeasible. Here, we present DeadEasy Mito-Glia, an image processing method to count automatically the number of mitotic cells labelled with anti-phospho-histone H3 and of glial cells labelled with anti-Repo in Drosophila embryos. This programme belongs to the DeadEasy suite of which we have previously developed versions to count apoptotic cells and neuronal nuclei. Having separate programmes is paramount for accuracy. DeadEasy Mito-Glia is very easy to use, fast, objective and very accurate when counting dividing cells and glial cells labelled with a nuclear marker. Although this method has been validated for Drosophila embryos, we provide an interactive window for biologists to easily extend its application to other nuclear markers and other sample types. DeadEasy MitoGlia is freely available as an ImageJ plug-in, it increases the repertoire of tools for in vivo genetic analysis, and it will be of interest to a broad community of developmental, cancer and neuro-biologists

    Effectiveness of electronic guideline-based implementation systems in ambulatory care settings - a systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Electronic guideline-based decision support systems have been suggested to successfully deliver the knowledge embedded in clinical practice guidelines. A number of studies have already shown positive findings for decision support systems such as drug-dosing systems and computer-generated reminder systems for preventive care services.</p> <p>Methods</p> <p>A systematic literature search (1990 to December 2008) of the English literature indexed in the Medline database, Embase, the Cochrane Central Register of Controlled Trials, and CRD (DARE, HTA and NHS EED databases) was conducted to identify evaluation studies of electronic multi-step guideline implementation systems in ambulatory care settings. Important inclusion criterions were the multidimensionality of the guideline (the guideline needed to consist of several aspects or steps) and real-time interaction with the system during consultation. Clinical decision support systems such as one-time reminders for preventive care for which positive findings were shown in earlier reviews were excluded. Two comparisons were considered: electronic multidimensional guidelines versus usual care (comparison one) and electronic multidimensional guidelines versus other guideline implementation methods (comparison two).</p> <p>Results</p> <p>Twenty-seven publications were selected for analysis in this systematic review. Most designs were cluster randomized controlled trials investigating process outcomes more than patient outcomes. With success defined as at least 50% of the outcome variables being significant, none of the studies were successful in improving patient outcomes. Only seven of seventeen studies that investigated process outcomes showed improvements in process of care variables compared with the usual care group (comparison one). No incremental effect of the electronic implementation over the distribution of paper versions of the guideline was found, neither for the patient outcomes nor for the process outcomes (comparison two).</p> <p>Conclusions</p> <p>There is little evidence at the moment for the effectiveness of an increasingly used and commercialised instrument such as electronic multidimensional guidelines. After more than a decade of development of numerous electronic systems, research on the most effective implementation strategy for this kind of guideline-based decision support systems is still lacking. This conclusion implies a considerable risk towards inappropriate investments in ineffective implementation interventions and in suboptimal care.</p

    Computerized clinical decision support systems for acute care management: A decision-maker-researcher partnership systematic review of effects on process of care and patient outcomes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Acute medical care often demands timely, accurate decisions in complex situations. Computerized clinical decision support systems (CCDSSs) have many features that could help. However, as for any medical intervention, claims that CCDSSs improve care processes and patient outcomes need to be rigorously assessed. The objective of this review was to systematically review the effects of CCDSSs on process of care and patient outcomes for acute medical care.</p> <p>Methods</p> <p>We conducted a decision-maker-researcher partnership systematic review. MEDLINE, EMBASE, Evidence-Based Medicine Reviews databases (Cochrane Database of Systematic Reviews, DARE, ACP Journal Club, and others), and the Inspec bibliographic database were searched to January 2010, in all languages, for randomized controlled trials (RCTs) of CCDSSs in all clinical areas. We included RCTs that evaluated the effect on process of care or patient outcomes of a CCDSS used for acute medical care compared with care provided without a CCDSS. A study was considered to have a positive effect (<it>i.e.</it>, CCDSS showed improvement) if at least 50% of the relevant study outcomes were statistically significantly positive.</p> <p>Results</p> <p>Thirty-six studies met our inclusion criteria for acute medical care. The CCDSS improved process of care in 63% (22/35) of studies, including 64% (9/14) of medication dosing assistants, 82% (9/11) of management assistants using alerts/reminders, 38% (3/8) of management assistants using guidelines/algorithms, and 67% (2/3) of diagnostic assistants. Twenty studies evaluated patient outcomes, of which three (15%) reported improvements, all of which were medication dosing assistants.</p> <p>Conclusion</p> <p>The majority of CCDSSs demonstrated improvements in process of care, but patient outcomes were less likely to be evaluated and far less likely to show positive results.</p
    corecore