21 research outputs found

    cExternal beam radiation results in minimal changes in post void residual urine volumes during the treatment of clinically localized prostate cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate the impact of external beam radiation therapy (XRT) on weekly ultrasound determined post-void residual (PVR) urine volumes in patients with prostate cancer.</p> <p>Methods</p> <p>125 patients received XRT for clinically localized prostate cancer. XRT was delivered to the prostate only (n = 66) or if the risk of lymph node involvement was greater than 10% to the whole pelvis followed by a prostate boost (n = 59). All patients were irradiated in the prone position in a custom hip-fix mobilization device with an empty bladder and rectum. PVR was obtained at baseline and weekly. Multiple clinical and treatment parameters were evaluated as predictors for weekly PVR changes.</p> <p>Results</p> <p>The mean patient age was 73.9 years with a mean pre-treatment prostate volume of 53.3 cc, a mean IPSS of 11.3 and a mean baseline PVR of 57.6 cc. During treatment, PVR decreased from baseline in both cohorts with the absolute difference within the limits of accuracy of the bladder scanner. Alpha-blockers did not predict for a lower PVR during treatment. There was no significant difference in mean PVR urine volumes or differences from baseline in either the prostate only or pelvic radiation groups (p = 0.664 and p = 0.458, respectively). Patients with a larger baseline PVR (>40 cc) had a greater reduction in PVR, although the greatest reduction was seen between weeks one and three. Patients with a small PVR (<40 cc) had no demonstrable change throughout treatment.</p> <p>Conclusion</p> <p>Prostate XRT results in clinically insignificant changes in weekly PVR volumes, suggesting that radiation induced bladder irritation does not substantially influence bladder residual urine volumes.</p

    Biological impact of geometric uncertainties: what margin is needed for intra-hepatic tumors?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate and compare the biological impact on different proposed margin recipes for the same geometric uncertainties for intra-hepatic tumors with different tumor cell types or clinical stages.</p> <p>Method</p> <p>Three different margin recipes based on tumor motion were applied to sixteen IMRT plans with a total of twenty two intra-hepatic tumors. One recipe used the full amplitude of motion measured from patients to generate margins. A second used 70% of the full amplitude of motion, while the third had no margin for motion. The biological effects of geometric uncertainty in these three situations were evaluated with Equivalent Uniform Doses (EUD) for various survival fractions at 2 Gy (SF<sub>2</sub>).</p> <p>Results</p> <p>There was no significant difference in the biological impact between the full motion margin and the 70% motion margin. Also, there was no significant difference between different tumor cell types. When the margin for motion was eliminated, the difference of the biological impact was significant among different cell types due to geometric uncertainties. Elimination of the motion margin requires dose escalation to compensate for the biological dose reduction due to the geometric misses during treatment.</p> <p>Conclusions</p> <p>Both patient-based margins of full motion and of 70% motion are sufficient to prevent serious dosimetric error. Clinical implementation of margin reduction should consider the tumor sensitivity to radiation.</p

    Iodine-125 brachytherapy for brain tumours - a review

    Get PDF
    Iodine-125 brachytherapy has been applied to brain tumours since 1979. Even though the physical and biological characteristics make these implants particularly attractive for minimal invasive treatment, the place for stereotactic brachytherapy is still poorly defined

    Defining target volumes for non-small cell lung carcinoma.

    No full text
    The definition of target volumes for non-small cell lung carcinoma (NSCLC) remains a controversial topic as tradition-based approaches of the past are being critically re-evaluated in the light of the advent of three-dimensional treatment techniques, by the awareness of the poor local control achieved using current treatment fields and radiation doses, and by the major improvements in noninvasive staging that enable the gross tumor volume to be established with greater accuracy. This article reviews the current knowledge and remaining uncertainties in defining target volumes for NSCLC. The use of these new approaches may allow for improvements in the therapeutic ratio of radiotherapy in NSCLC

    Comparing different NTCP models that predict the incidence of radiation pneumonitis

    No full text
    Purpose: To compare different normal tissue complication probability (NTCP) models to predict the incidence of radiation pneumonitis on the basis of the dose distribution in the lung. Methods and Materials: The data from 382 breast cancer, malignant lymphoma, and inoperable non-small-cell lung cancer patients from two centers were studied. Radiation pneumonitis was scored using the Southwestern Oncology Group criteria. Dose-volume histograms of the lungs were calculated from the dose distributions that were corrected for dose per fraction effects. The dose-volume histogram of each patient was reduced to a single parameter using different local dose-effect relationships. Examples of single parameters were the mean lung dose (MLD) and the volume of lung receiving more than a threshold dose (V-Dth). The parameters for the different NTCP models were fit to patient data using a maximum likelihood analysis. Results: The best fit resulted in a linear local dose-effect relationship, with the MLD as the resulting single parameter. The relationship between the MLD and NTCP could be described with a median toxic dose (TD50) of 30.8 Gy and a steepness parameter m of 0.37. The best fit for the relationship between the V-Dth and the NTCP was obtained with a D-th of 13 Gy. The MLD model was found to be significantly better than the VIth model (p 35%. For arbitrary dose distributions, an estimate of the uncertainty in the NTCP could be determined using the probability distribution of the parameter values of the Lyman-Kutcher-Burman model. Conclusion: The maximum likelihood method revealed that the underlying local dose-effect relation for radiation pneumonitis was linear (the MLD model), rather than a step function (the V-Dth model). Thus, for the studied patient population, the MLD was the most accurate predictor for the incidence of radiation pneumonitis. (C) 2003 Elsevier Science Inc
    corecore