3 research outputs found

    Severe traumatic injury during long duration spaceflight: Light years beyond ATLS

    Get PDF
    Traumatic injury strikes unexpectedly among the healthiest members of the human population, and has been an inevitable companion of exploration throughout history. In space flight beyond the Earth's orbit, NASA considers trauma to be the highest level of concern regarding the probable incidence versus impact on mission and health. Because of limited resources, medical care will have to focus on the conditions most likely to occur, as well as those with the most significant impact on the crew and mission. Although the relative risk of disabling injuries is significantly higher than traumatic deaths on earth, either issue would have catastrophic implications during space flight. As a result this review focuses on serious life-threatening injuries during space flight as determined by a NASA consensus conference attended by experts in all aspects of injury and space flight

    Operational evaluation of the earlobe arterialized blood collector in critically ill patients

    Get PDF
    The new Earlobe Arterialized Blood Collector (EABC®) is a minimally invasive prototype system able to perform capillary blood collection from the earlobe (EL) with minimal training and risk. This system could improve medical emergency management in extreme environments. Consequently, a prospective validation study was designed to evaluate operational performance of the EABC® in a cohort of critically ill patients. Arterialized capillary blood was sampled from the EL of 55 invasively ventilated patients using the EABC® following a validated procedure. Operational characteristics such as the number of cuts and cartridges required, sampling failure/success ratio, bleeding complications, storage requirements and other auxiliary aspects were recorded. Result turnaround laboratory times (TAT) were compared with published references. Blood collection was as easily performed on one earlobe as the other. Twenty-six minutes (mean 25.8; SD = 3.8) were required to obtain results, 15 min for patient preparation (mean 15.3; SD = 2.6) + 11 min for sampling and analysis (mean 11.4; SD = 2.1), which is similar to published hospital reference laboratory TAT. The average number of cartridges required was 1.3 (1-3; mode = 1) with the mean number of cut attempts being 1.2 (1-4; mode = 1). Problems/difficulties occurred in 59% of cases but were mainly attributed to patient's demographic characteristics, with only 10% attributable to the collector (superficial cut, blood leak, collector misalignment and obstructed vision). Haemostasis was quickly achieved with minimum complications. Storage of the complete sampling kit required a 300 × 300 × 300 mm box. Two 9-V batteries were used during the 2-year study period. The new EABC® system concept is safe, fast and easy to use. Observed problems/difficulties are easily amendable with certain design modifications. Definitive versions of the prototype have the potential for significant benefits for isolated and extreme environments in medicine
    corecore