195 research outputs found

    Quantifying the improvement of surrogate indices of hepatic insulin resistance using complex measurement techniques

    Get PDF
    We evaluated the ability of simple and complex surrogate-indices to identify individuals from an overweight/obese cohort with hepatic insulin-resistance (HEP-IR). Five indices, one previously defined and four newly generated through step-wise linear regression, were created against a single-cohort sample of 77 extensively characterised participants with the metabolic syndrome (age 55.6±1.0 years, BMI 31.5±0.4 kg/m2; 30 males). HEP-IR was defined by measuring endogenous-glucose-production (EGP) with [6–62H2] glucose during fasting and euglycemic-hyperinsulinemic clamps and expressed as EGP*fasting plasma insulin. Complex measures were incorporated into the model, including various non-standard biomarkers and the measurement of body-fat distribution and liver-fat, to further improve the predictive capability of the index. Validation was performed against a data set of the same subjects after an isoenergetic dietary intervention (4 arms, diets varying in protein and fiber content versus control). All five indices produced comparable prediction of HEP-IR, explaining 39–56% of the variance, depending on regression variable combination. The validation of the regression equations showed little variation between the different proposed indices (r2 = 27–32%) on a matched dataset. New complex indices encompassing advanced measurement techniques offered an improved correlation (r = 0.75, P<0.001). However, when validated against the alternative dataset all indices performed comparably with the standard homeostasis model assessment for insulin resistance (HOMA-IR) (r = 0.54, P<0.001). Thus, simple estimates of HEP-IR performed comparable to more complex indices and could be an efficient and cost effective approach in large epidemiological investigations

    Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    Get PDF
    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of this technique in patients who were treated for an intracranial aneurysm. Four repeated measurements of blood volume (BV) were performed in random order of bolus dose (10 mg or 25 mg ICG) and venous administration site (peripheral or central) in eight patients admitted for treatment of an intracranial aneurysm. Another five patients with subarachnoid hemorrhage underwent three repeated BV measurements with 25 mg ICG at the same administration site to assess the coefficient of variation. The mean +/- SD in BV was 4.38 +/- 0.88 l (n = 25) and 4.69 +/- 1.11 l (n = 26) for 10 mg and 25 mg ICG, respectively. The mean +/- SD in BV was 4.59 +/- 1.15 l (n = 26) and 4.48 +/- 0.86 l (n = 25) for central and peripheral administration, respectively. No significant difference was found. The coefficient of variance of BV measurement with 25 mg of ICG was 7.5% (95% CI: 3-12%). There is no significant difference between intravenous administration of either 10 or 25 mg ICG, and this can be injected through either a peripheral or central venous catheter. The 7.5% coefficient of variation in BV measurements determines the detectable differences using ICG pulse spectrophotometr

    Emergency department documentation templates: variability in template selection and association with physical examination and test ordering in dizziness presentations

    Get PDF
    Abstract Background Clinical documentation systems, such as templates, have been associated with process utilization. The T-System emergency department (ED) templates are widely used but lacking are analyses of the templates association with processes. This system is also unique because of the many different template options available, and thus the selection of the template may also be important. We aimed to describe the selection of templates in ED dizziness presentations and to investigate the association between items on templates and process utilization. Methods Dizziness visits were captured from a population-based study of EDs that use documentation templates. Two relevant process outcomes were assessed: head computerized tomography (CT) scan and nystagmus examination. Multivariable logistic regression was used to estimate the probability of each outcome for patients who did or did not receive a relevant-item template. Propensity scores were also used to adjust for selection effects. Results The final cohort was 1,485 visits. Thirty-one different templates were used. Use of a template with a head CT item was associated with an increase in the adjusted probability of head CT utilization from 12.2% (95% CI, 8.9%-16.6%) to 29.3% (95% CI, 26.0%-32.9%). The adjusted probability of documentation of a nystagmus assessment increased from 12.0% (95%CI, 8.8%-16.2%) when a nystagmus-item template was not used to 95.0% (95% CI, 92.8%-96.6%) when a nystagmus-item template was used. The associations remained significant after propensity score adjustments. Conclusions Providers use many different templates in dizziness presentations. Important differences exist in the various templates and the template that is used likely impacts process utilization, even though selection may be arbitrary. The optimal design and selection of templates may offer a feasible and effective opportunity to improve care delivery.http://deepblue.lib.umich.edu/bitstream/2027.42/112490/1/12913_2010_Article_1586.pd

    Analysis of coding variants in the betacellulin gene in type 2 diabetes and insulin secretion in African American subjects

    Get PDF
    BACKGROUND: Betacellulin is a member of the epidermal growth factor family, expressed at the highest levels predominantly in the pancreas and thought to be involved in islet neogenesis and regeneration. Nonsynonymous coding variants were reported to be associated with type 2 diabetes in African American subjects. We tested the hypotheses that these previously identified variants were associated with type 2 diabetes in African Americans ascertained in Arkansas and that they altered insulin secretion in glucose tolerant African American subjects. METHODS: We typed three variants, exon1 Cys7Gly (C7G), exon 2 Leu44Phe (L44F), and exon 4 Leu124Met (L124M), in 188 control subjects and 364 subjects with type 2 diabetes. We tested for altered insulin secretion in 107 subjects who had undergone intravenous glucose tolerance tests to assess insulin sensitivity and insulin secretion. RESULTS: No variant was associated with type 2 diabetes, and no variant altered insulin secretion or insulin sensitivity. However, an effect on lipids was observed for all 3 variants, and variant L124M was associated with obesity measures. CONCLUSION: We were unable to confirm a role for nonsynonymous variants of betacellulin in the propensity to type 2 diabetes or to impaired insulin secretion

    Reversal of type 2 diabetes: normalisation of beta cell function in association with decreased pancreas and liver triacylglycerol

    Get PDF
    The presence of Fc-receptor-blocking factors in the sera of normal and insulin-dependent diabetic pregnant women was investigated by means of an antibody-dependent cell-mediated cytotoxicity assay. Sera from normal pregnant women induced a significant depression of antibody dependent cell-mediated cytotoxicity when compared with sera from normal and diabetic non-pregnant women (p less than 0.0001; p less than 0.002, respectively). The effect of sera from diabetic pregnant women, however, was not different from that observed with sera from normal and diabetic non-pregnant women. Thus, we confirm the presence of Fc-receptor-blocking factors in the sera of normal pregnant women. The higher cytotoxicity levels measured in the presence of sera from pregnant women with insulin-dependent diabetes suggests that the titres of such factors are reduced in this conditio

    Water T2 as an early, global and practical biomarker for metabolic syndrome: an observational cross-sectional study

    Get PDF
    Background: Metabolic syndrome (MetS) is a highly prevalent condition that identifies individuals at risk for type 2 diabetes mellitus and atherosclerotic cardiovascular disease. Prevention of these diseases relies on early detection and intervention in order to preserve pancreatic β-cells and arterial wall integrity. Yet, the clinical criteria for MetS are insensitive to the early-stage insulin resistance, inflammation, cholesterol and clotting factor abnormalities that char- acterize the progression toward type 2 diabetes and atherosclerosis. Here we report the discovery and initial charac- terization of an atypical new biomarker that detects these early conditions with just one measurement. Methods: Water T2, measured in a few minutes using benchtop nuclear magnetic resonance relaxometry, is exqui- sitely sensitive to metabolic shifts in the blood proteome. In an observational cross-sectional study of 72 non-diabetic human subjects, the association of plasma and serum water T2 values with over 130 blood biomarkers was analyzed using bivariate, multivariate and logistic regression. Results: Plasma and serum water T2 exhibited strong bivariate correlations with markers of insulin, lipids, inflamma- tion, coagulation and electrolyte balance. After correcting for confounders, low water T2 values were independently and additively associated with fasting hyperinsulinemia, dyslipidemia and subclinical inflammation. Plasma water T2 exhibited 100% sensitivity and 87% specificity for detecting early insulin resistance in normoglycemic subjects, as defined by the McAuley Index. Sixteen normoglycemic subjects with early metabolic abnormalities (22% of the study population) were identified by low water T2 values. Thirteen of the 16 did not meet the harmonized clinical criteria for metabolic syndrome and would have been missed by conventional screening for diabetes risk. Low water T2 values were associated with increases in the mean concentrations of 6 of the 16 most abundant acute phase proteins and lipoproteins in plasma. Conclusions: Water T2 detects a constellation of early abnormalities associated with metabolic syndrome, provid- ing a global view of an individual’s metabolic health. It circumvents the pitfalls associated with fasting glucose and hemoglobin A1c and the limitations of the current clinical criteria for metabolic syndrome. Water T2 shows promise as an early, global and practical screening tool for the identification of individuals at risk for diabetes and atherosclerosis

    Chronic Obstructive Pulmonary Disease, inflammation and co-morbidity – a common inflammatory phenotype?

    Get PDF
    Chronic Obstructive Pulmonary Disease (COPD) is and will remain a major cause of morbidity and mortality worldwide. The severity of airflow obstruction is known to relate to overall health status and mortality. However, even allowing for common aetiological factors, a link has been identified between COPD and other systemic diseases such as cardiovascular disease, diabetes and osteoporosis. COPD is known to be an inflammatory condition and neutrophil elastase has long been considered a significant mediator of the disease. Pro-inflammatory cytokines, in particular TNF-α (Tumour Necrosis Factor alpha), may be the driving force behind the disease process. However, the roles of inflammation and these pro-inflammatory cytokines may extend beyond the lungs and play a part in the systemic effects of the disease and associated co-morbidities. This article describes the mechanisms involved and proposes a common inflammatory TNF-α phenotype that may, in part, account for the associations
    corecore