3,681 research outputs found

    Population structures in the SARA and SARB reference collections of Salmonella enterica according to MLST, MLEE and microarray hybridization

    Get PDF
    In the 1980's and 1990's, population genetic analyses based on Multilocus Enzyme Electrophoresis (MLEE) provided an initial overview of the genetic diversity of multiple bacterial species, including Salmonella enterica. The genetic diversity within S. enterica subspecies enterica according to MLEE is represented by the SARA and SARB reference collections, each consisting of 72 isolates, which have been extensively used for comparative analyses. MLEE has subsequently been replaced by Multilocus Sequence Typing (MLST). Our initial MLST results indicated that some strains within the SARB collection differed from their published descriptions. We therefore performed MLST on four versions of the SARB collection from different sources and one collection of SARA, and found that multiple isolates in SARB and SARA differ in serovar from their original description, and other SARB isolates differed between different sources. Comparisons with a global MLST database allowed a plausible reconstruction of the serovars of the original collection. MLEE, MLST and microarrays were largely concordant at recognizing closely related strains. MLST was particularly effective at recognizing discrete population genetic groupings while the two other methods provided hints of higher order relationships. However, quantitative pair-wise phylogenetic distances differed considerably between all three methods. Our results provide a translation dictionary from MLEE to MLST for the extant SARA and SARB collections which can facilitate genomic comparisons based on archival insights from MLEE

    Growth of non-polar InGaN quantum dots with an underlying AlN/GaN distributed Bragg reflector by metal-organic vapour phase epitaxy

    Get PDF
    Non-polar (11-20) InGaN quantum dots (QDs) have been grown using a modified droplet epitaxy method by metal-organic vapour phase epitaxy on top of a 15-period AlN/GaN distributed Bragg reflector (DBR) on a-plane GaN pseudo-substrate prepared by epitaxial lateral overgrowth (ELOG), in which the QDs are located at the centre of a ca. 180 nm GaN layer. The AlN/GaN DBR has shown a peak reflectivity of ~80% at a wavelength of ~454 nm with a 49 nm wide, flat stop-band. Variations in layer thicknesses observed by cross-sectional scanning transmission electron microscopy have been identified as the main source of degradation of the DBR reflectivity. The presence of trenches due to incomplete coalescence of the ELOG template and the formation of cracks due to relaxation of tensile strain during the DBR growth may distort the DBR and further reduce the reflectivity. The DBR top surface is very smooth and does not have a detrimental effect on the subsequent growth of QDs. Enhanced single QD emission at 20 K was observed in cathodoluminescence.This work has been funded by the EPSRC (Grant No. EP/H047816/1 and EP/J001627/1).This is the final version of the article. It first appeared from Elsevier via http://dx.doi.org/10.1016/j.spmi.2015.10.00

    Fiber Acoustic Waveguide : A Sensor Candidate

    Get PDF
    Sensor development plays a key role in the field of nondestructive evaluation and process control. The annual fiber optic sensor market alone is a multimillion dollar business (1). Acoustic waves are about five orders of magnitude slower than optical waves and can also be guided in cladded glass fibers, similar to optical fibers, with low loss and low dispersion (2–7). Fiber acoustic waveguides are believed to be a very attractive and basic component for further sensor development (8). In this paper a brief theoretical description of a weakly guiding acoustic fiber (7) is given. The material selection criteria for the core and the cladding of the fiber guide, the properties of single-mode operation, and some sensing mechanisms for temperature and pressure variations are discussed. The acoustic waveguide with a liquid core is also considered

    A Novel Approach for Ellipsoidal Outer-Approximation of the Intersection Region of Ellipses in the Plane

    Get PDF
    In this paper, a novel technique for tight outer-approximation of the intersection region of a finite number of ellipses in 2-dimensional (2D) space is proposed. First, the vertices of a tight polygon that contains the convex intersection of the ellipses are found in an efficient manner. To do so, the intersection points of the ellipses that fall on the boundary of the intersection region are determined, and a set of points is generated on the elliptic arcs connecting every two neighbouring intersection points. By finding the tangent lines to the ellipses at the extended set of points, a set of half-planes is obtained, whose intersection forms a polygon. To find the polygon more efficiently, the points are given an order and the intersection of the half-planes corresponding to every two neighbouring points is calculated. If the polygon is convex and bounded, these calculated points together with the initially obtained intersection points will form its vertices. If the polygon is non-convex or unbounded, we can detect this situation and then generate additional discrete points only on the elliptical arc segment causing the issue, and restart the algorithm to obtain a bounded and convex polygon. Finally, the smallest area ellipse that contains the vertices of the polygon is obtained by solving a convex optimization problem. Through numerical experiments, it is illustrated that the proposed technique returns a tighter outer-approximation of the intersection of multiple ellipses, compared to conventional techniques, with only slightly higher computational cost

    Nano-cathodoluminescence reveals the effect of electron damage on the optical properties of nitride optoelectronics and the damage threshold

    Get PDF
    Nano-cathodoluminescence (Nano-CL) reveals optical emission from individual InGaN quantum wells for applications in optoelectronic devices. We show the luminescent intensity decays over time with exposure to the electron beam for energies between 80 and 200 keV. Measurements of the CL intensity over time show an exponential decline in intensity, which we propose is due to the formation of nitrogen Frenkel defects. The measured CL damage decreases with reductions in the electron accelerating voltage and we suggest that the electron induced structural damage may be suppressed below the proposed damage threshold. The electron beam induced damage leads to a non-radiative region that extends over the measured minority carrier diffusion length. Nano-CL may thus serve as a powerful technique to study III-nitride optoelectronics.This work was carried out with the support of the United Kingdom Engineering and Physical Sciences Research Council under Grant Nos. EP/NO17927/1 and EP/J003603/1. R. Oliver acknowledges funding from the European Research Council under the European Community's Seventh Framework Programme (FP7/2007-2013) ERC grant agreement number 279361 (MACONS) and the from the Royal Academy of Engineers/Leverhulme Trust senior research fellowship

    Cholestatic hepatitis as a possible new side-effect of oxycodone: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Oxycodone is a widely-used semisynthetic opioid analgesic that has been used for over eighty years. Oxycodone is known to cause side effects such as nausea, pruritus, dizziness, constipation and somnolence. As far as we are aware cholestatic hepatitis as a result of oxycodone use has not been reported so far in the world literature.</p> <p>Case presentation</p> <p>A 34-year-old male presented with cholestatic jaundice and severe pruritus after receiving oxycodone for analgesia post-T11 vertebrectomy. Extensive laboratory investigations and imaging studies did not reveal any other obvious cause for his jaundice and a liver biopsy confirmed canalicular cholestatis suggestive of drug-induced hepatotoxicity. The patient's symptoms and transaminases normalised on withdrawal of oxycodone confirming that oxycodone was the probable cause of the patient's hepatotoxicity.</p> <p>Conclusion</p> <p>We conclude that cholestatic hepatitis is possibly a rare side effect of oxycodone use. Physicians should be aware of the possibility of this potentially serious picture of drug-induced hepatotoxicity.</p

    Relationship between FEV1 change and patient-reported outcomes in randomised trials of inhaled bronchodilators for stable COPD: a systematic review.

    Get PDF
    BACKGROUND: Interactions between spirometry and patient-reported outcomes in COPD are not well understood. This systematic review and study-level analysis investigated the relationship between changes in FEV1 and changes in health status with bronchodilator therapy. METHODS: Six databases (to October 2009) were searched to identify studies with long-acting bronchodilator therapy reporting FEV1 and health status, dyspnoea or exacerbations. Mean and standard deviations of treatment effects were extracted for each arm of each study. Relationships between changes in trough FEV1 and outcomes were assessed using correlations and random-effects regression modelling. The primary outcome was St George's Respiratory Questionnaire (SGRQ) total score. RESULTS: Thirty-six studies (≥ 3 months) were included. Twenty-two studies (23,654 patients) with 49 treatment arms each contributing one data point provided SGRQ data. Change in trough FEV1 and change in SGRQ total score were negatively correlated (r = -0.46, p < 0.001); greater increases in FEV1 were associated with greater reductions (improvements) in SGRQ. The correlation strengthened with increasing study duration from 3 to 12 months. Regression modelling indicated that 100 mL increase in FEV1 (change at which patients are more likely to report improvement) was associated with a statistically significant reduction in SGRQ of 2.5 (95% CI 1.9, 3.1), while a clinically relevant SGRQ change (4.0) was associated with 160.6 (95% CI 129.0, 211.6) mL increase in FEV1. The association between change in FEV1 and other patient-reported outcomes was generally weak. CONCLUSIONS: Our analyses indicate, at a study level, that improvement in mean trough FEV1 is associated with proportional improvements in health status

    ‘New Medicine Service’: supporting adherence in people starting a new medication for a long-term condition: 26-week follow-up of a pragmatic randomised controlled trial

    Get PDF
    OBJECTIVE: To examine the effectiveness and cost-effectiveness of the community pharmacy New Medicine Service (NMS) at 26 weeks. METHODS: Pragmatic patient-level parallel randomised controlled trial in 46 English community pharmacies. 504 participants aged ≥14, identified in the pharmacy when presenting a prescription for a new medicine for predefined long-term conditions, randomised to receive NMS (n=251) or normal practice (n=253) (NMS intervention: 2 consultations 1 and 2 weeks after prescription presentation). Adherence assessed through patient self-report at 26-week follow-up. Intention-to-treat analysis employed. National Health Service (NHS) costs calculated. Disease-specific Markov models estimating impact of non-adherence combined with clinical trial data to calculate costs per extra quality-adjusted life-year (QALY; NHS England perspective). RESULTS: Unadjusted analysis: of 327 patients still taking the initial medicine, 97/170 (57.1%) and 103/157 (65.6%) (p=0.113) patients were adherent in normal practice and NMS arms, respectively. Adjusted intention-to-treat analysis: adherence OR 1.50 (95% CI 0.93 to 2.44, p=0.095), in favour of NMS. There was a non-significant reduction in 26-week NHS costs for NMS: -£104 (95% CI -£37 to £257, p=0.168) per patient. NMS generated a mean of 0.04 (95% CI -0.01 to 0.13) more QALYs per patient, with mean reduction in lifetime cost of -£113.9 (-1159.4, 683.7). The incremental cost-effectiveness ratio was -£2758/QALY (2.5% and 97.5%: -38 739.5, 34 024.2. NMS has an 89% probability of cost-effectiveness at a willingness to pay of £20 000 per QALY. CONCLUSIONS: At 26-week follow-up, NMS was unable to demonstrate a statistically significant increase in adherence or reduction in NHS costs, which may be attributable to patient attrition from the study. Long-term economic evaluation suggested NMS may deliver better patient outcomes and reduced overall healthcare costs than normal practice, but uncertainty around this finding is high. TRIAL REGISTRATION NUMBER: NCT01635361, ISRCTN23560818, ISRCTN23560818, UKCRN12494

    Consumption patterns of sweet drinks in a population of Australian children and adolescents (2003–2008)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Intake of sweet drinks has previously been associated with the development of overweight and obesity among children and adolescents. The present study aimed to assess the consumption pattern of sweet drinks in a population of children and adolescents in Victoria, Australia.</p> <p>Methods</p> <p>Data on 1,604 children and adolescents (4–18 years) from the comparison groups of two quasi-experimental intervention studies from Victoria, Australia were analysed<it>.</it> Sweet drink consumption (soft drink and fruit juice/cordial) was assessed as one day’s intake and typical intake over the last week or month at two time points between 2003 and 2008 (mean time between measurement: 2.2 years).</p> <p>Results</p> <p>Assessed using dietary recalls, more than 70% of the children and adolescents consumed sweet drinks, with no difference between age groups (p = 0.28). The median intake among consumers was 500 ml and almost a third consumed more than 750 ml per day. More children and adolescents consumed fruit juice/cordial (69%) than soft drink (33%) (p < 0.0001) and in larger volumes (median intake fruit juice/cordial: 500 ml and soft drink: 375 ml). Secular changes in sweet drink consumption were observed with a lower proportion of children and adolescents consuming sweet drinks at time 2 compared to time 1 (significant for age group 8 to <10 years, p = 0.001).</p> <p>Conclusion</p> <p>The proportion of Australian children and adolescents from the state of Victoria consuming sweet drinks has been stable or decreasing, although a high proportion of this sample consumed sweet drinks, especially fruit juice/cordial at both time points.</p
    corecore