67 research outputs found

    The Target Silicon Detector for the FOCUS Spectrometer

    Full text link
    We describe a silicon microstrip detector interleaved with segments of a beryllium oxide target which was used in the FOCUS photoproduction experiment at Fermilab. The detector was designed to improve the vertex resolution and to enhance the reconstruction efficiency of short-lived charm particles.Comment: 18 pages, 14 figure

    Neutralizing antibody vaccine for pandemic and pre-emergent coronaviruses

    Get PDF
    Betacoronaviruses (betaCoVs) caused the severe acute respiratory syndrome (SARS) and Middle East Respiratory Syndrome (MERS) outbreaks, and the SARS-CoV-2 pandemic1–4. Vaccines that elicit protective immunity against SARS-CoV-2 and betaCoVs circulating in animals have the potential to prevent future betaCoV pandemics. Here, we show that macaque immunization with a multimeric SARS-CoV-2 receptor binding domain (RBD) nanoparticle adjuvanted with 3M-052/Alum elicited cross-neutralizing antibody (cross-nAb) responses against batCoVs, SARS-CoV-1, SARS-CoV-2, and SARS-CoV-2 variants B.1.1.7, P.1, and B.1.351. Nanoparticle vaccination resulted in a SARS-CoV-2 reciprocal geometric mean neutralization ID50 titer of 47,216, and protection against SARS-CoV-2 in macaque upper and lower respiratory tracts. Importantly, nucleoside-modified mRNA encoding a stabilized transmembrane spike or monomeric RBD also induced SARS-CoV-1 and batCoV cross-nAbs, albeit at lower titers. These results demonstrate current mRNA vaccines may provide some protection from future zoonotic betaCoV outbreaks, and provide a platform for further development of pan-betaCoV vaccines

    Mouse Chromosome 11

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/46996/1/335_2004_Article_BF00648429.pd

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens

    No full text
    Aims—To compare the performance of a new generation dual amplified enzyme immunoassay (EIA) with a molecular method for the diagnosis of Chlamydia trachomatis, using a range of urogenital samples, and to assess the reliability of testing self collected vaginal specimens compared with clinician collected vaginal specimens. Methods—Two population groups were tested. For the first population group, first void urine samples were collected from 193 male patients with urethritis, and endocervical swabs were collected from 187 high risk commercial sex workers. All urine and endocervical specimens were tested by a conventional assay (IDEIA chlamydia), a new generation amplified immunoassay (IDEIA PCE chlamydia), and the Amplicor polymerase chain reaction (PCR). Discrepant results obtained among the three sample types were confirmed using a nested PCR test with a different plasmid target region. For the second population group, four swab specimens, including one patient obtained vaginal swab, two clinician obtained endocervical swabs, and one clinician obtained vaginal swab, were collected from 91 high risk sex workers. Self collected and clinician collected vaginal swabs were tested by IDEIA PCE chlamydia. Clinician obtained endocervical swabs were assayed by IDEIA PCE chlamydia and Amplicor PCR. Results—The performance of the IDEIA PCE chlamydia test was comparable to that of the Amplicor PCR test when male urine and female endocervical swab specimens were analysed. The relative sensitivities of IDEIA, IDEIA PCE, and Amplicor PCR on male first void urine specimens were 79.3%, 91.4%, and 100%, respectively. The relative sensitivities of the three tests on female endocervical specimens were 85.0%, 95.0%, and 100%, respectively. The positivity rates for patient collected vaginal specimens and clinician collected vaginal specimens by IDEIA PCE were 25.2% and 23.1%, respectively, whereas those for clinician collected endocervical swabs by PCR and IDEIA PCE were both 27.5%. Conclusions—IDEIA PCE chlamydia is a lower cost but sensitive alternative test to PCR for testing male urine samples and female endocervical swabs. In addition, self collected or clinician collected vaginal specimens tested by IDEIA PCE chlamydia are a reliable alternative to analysing endocervical specimens. Key Words: Chlamydia trachomatis • enzyme immunoassay • clinical specimen

    Mechanical properties of an ultrafine-grained Al-7.5 pct Mg alloy

    No full text
    In the present study, the relationships between the structure and properties of a cryomilled Al-7.5 pct Mg alloy were investigated. The microstructure of the cryomilled Al-7.5 pct Mg alloy consisted of equiaxed grains with an approximate size of 300 nm. Thermal treatment had only a minor effect on microstructure, as evidenced by X-ray diffraction (XRD) and transmission electron microscopy (TEM) results. The tensile behavior was characterized by high strength, high ductility, and low-strain-hardening. The tensile deformation was relatively uniform, with limited necking deformation, and fracture surfaces were characterized by microdimples. The variation of strain rates from 4 (.) 10(-4) to 4 (.) 10(-2) s(-1) had an insignificant effect on tensile behavior. Comparison of compressive and tensile behavior revealed similar moduli and yield strengths, although the postyield behavior was markedly asymmetric. The present results indicate that grain-size effects, solid-solution strengthening, Orowan strengthening, and dislocation strengthening contribute significantly to the properties of a cryomilled Al-7.5 pct Mg alloy.close9710
    corecore