334 research outputs found

    Impact of endometritis on post-partum ovarian cyclicity in dairy cows

    Get PDF
    Endometritis in dairy cows is a major global issue and has been associated with a decrease in reproductive performance. The aim of this study was to quantify the effect of endometritis (as defined by the presence of any abnormal vaginal discharge after 21 days post-partum) on post-partum ovarian cyclicity in dairy cows. Milk progesterone analysis was used to monitor reproductive cyclicity in 170 dairy cows across three different commercial herds. Associations between the occurrence of endometritis and the incidence risk of a variety of atypical cycle profiles during the calving to conception period were investigated to establish the importance of endometritis on post-partum ovarian activity.Endometritis increased the incidence odds of atypical ovarian profiles (P [less than] 0.05) with prolonged luteal activity being the most affected (P [less than] 0.05), but also showed prolonged time (3 days) to onset of luteal activity after parturition (P [less than] 0.05). Using milk progesterone analysis, we found a relatively low incidence odds for reproductive cycle problems in healthy cows during the calving to conception period. However, the incidence odds of cycle problems, in particular prolonged luteal activity, were high in cows that had experienced endometritis, which would have significantly impaired reproductive function

    Hybrid dual mode sensor for simultaneous detection of two serum metabolites

    Get PDF
    Metabolites are the ultimate readout of disease phenotype that plays a significant role in the study of human disease. Multiple metabolites sometimes serve as biomarkers for a single metabolic disease. Therefore, simultaneous detection and analysis of those metabolites facilitate early diagnostics of the disease. Conventional approaches to detect and quantify metabolites include mass spectrometry and nuclear magnetic resonance that require bulky and expensive equipment. Here, we present a disposable sensing platform that is based on complementary metal–oxide–semiconductor process. It contains two sensors: an ion sensitive field-effect transistor and photodiode that can work independently for detection of pH and color change produced during the metabolite-enzyme reaction. Serum glucose and cholesterol have been detected and quantified simultaneously with the new platform, which shows good sensitivity within the physiological range. Low cost and easy manipulation make our device a prime candidate for personal metabolome sensing diagnostics

    Low Noise and High Photodetection Probability SPAD in 180 nm Standard CMOS Technology

    Get PDF
    A square shaped, low noise and high photo-response single photon avalanche diode suitable for circuit integration, implemented in a standard CMOS 180 nm high voltage technology, is presented. In this work, a p+ to shallow n-well junction was engineered with a very smooth electric field profile guard ring to attain a photo detection probability peak higher than 50% with a median dark count rate lower than 2 Hz/μm2 when operated at an excess bias of 4 V. The reported timing jitter full width at half maximum is below 300 ps for 640 nm laser pulses

    Hybrid Amperometric and Potentiometric Sensing Based on a CMOS ISFET Array

    Get PDF
    Potentiometry and amperometry are some of the most important techniques for electroanalytical applications. Integrating these two techniques on a single chip using CMOS technology paves the way for more analysis and measurement of chemical solutions. In this paper, we describe the integration of electrode transducers (amperometry) on an ion imager based on an ISFET array (potentiometry). In particular, this integration enables the spatial representation of the potential distribution of active electrodes in a chemical solution under investigation

    Wide-Range Optical CMOS-Based Diagnostics

    Get PDF
    Colorimetric, chemiluminescence and refractive index based diagnostics are some of the most important sensing techniques in biomedical science and clinical medicine. Conventionally laboratories and medical clinics rely on bulky and dedicated equipment for each diagnostic technique independently. In this paper, we present CMOS sensor based solutions, comprising a single photon avalanche detector array and photodiode array. The CMOS platform offers low cost integration and wide range of light-based diagnostic techniques, leading to development of point-of-care devices

    A 16 x 16 CMOS amperometric microelectrode array for simultaneous electrochemical measurements

    Get PDF
    There is a requirement for an electrochemical sensor technology capable of making multivariate measurements in environmental, healthcare, and manufacturing applications. Here, we present a new device that is highly parallelized with an excellent bandwidth. For the first time, electrochemical cross-talk for a chip-based sensor is defined and characterized. The new CMOS electrochemical sensor chip is capable of simultaneously taking multiple, independent electroanalytical measurements. The chip is structured as an electrochemical cell microarray, comprised of a microelectrode array connected to embedded self-contained potentiostats. Speed and sensitivity are essential in dynamic variable electrochemical systems. Owing to the parallel function of the system, rapid data collection is possible while maintaining an appropriately low-scan rate. By performing multiple, simultaneous cyclic voltammetry scans in each of the electrochemical cells on the chip surface, we are able to show (with a cell-to-cell pitch of 456 μm) that the signal cross-talk is only 12% between nearest neighbors in a ferrocene rich solution. The system opens up the possibility to use multiple independently controlled electrochemical sensors on a single chip for applications in DNA sensing, medical diagnostics, environmental sensing, the food industry, neuronal sensing, and drug discovery

    Monolithic Integration of a Plasmonic Sensor with CMOS Technology

    Get PDF
    Monolithic integration of nanophotonic sensors with CMOS detectors can transform the laboratory based nanophotonic sensors into practical devices with a range of applications in everyday life. In this work, by monolithically integrating an array of gold nanodiscs with the CMOS photodiode we have developed a compact and miniaturized nanophotonic sensor system having direct electrical read out. Doing so eliminates the need of expensive and bulky laboratory based optical spectrum analyzers used currently for measurements of nanophotonic sensor chips. The experimental optical sensitivity of the gold nanodiscs is measured to be 275 nm/RIU which translates to an electrical sensitivity of 5.4 V/RIU. This integration of nanophotonic sensors with the CMOS electronics has the potential to revolutionize personalized medical diagnostics similar to the way in which the CMOS technology has revolutionized the electronics industry

    A New Dental Superalloy System: IV. X-Ray Diffraction Analysis

    Full text link
    X-ray diffraction analysis of the alloy system Co-Ni-Cr-Ta showed that the ternary alloy base consisted of three phases (a, β, and σ). Addition of Ta caused a decrease in the intensity of the β lines. Further Ta additions caused diffraction lines characteristic of the intermetallic compound α-Co3Ta. At higher Ta concentrations, the intensity of the lines characteristic of the σ phase increased and lines characteristic of Co2Ta appeared.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/66588/2/10.1177_00220345730520041701.pd

    An integrated circuit for chip-based analysis of enzyme kinetics and metabolite quantification

    Get PDF
    We have created a novel chip-based diagnostic tools based upon quantification of metabolites using enzymes specific for their chemical conversion. Using this device we show for the first time that a solid-state circuit can be used to measure enzyme kinetics and calculate the Michaelis-Menten constant. Substrate concentration dependency of enzyme reaction rates is central to this aim. Ion-sensitive field effect transistors (ISFET) are excellent transducers for biosensing applications that are reliant upon enzyme assays, especially since they can be fabricated using mainstream microelectronics technology to ensure low unit cost, mass-manufacture, scaling to make many sensors and straightforward miniaturisation for use in point-of-care devices. Here, we describe an integrated ISFET array comprising 216 sensors. The device was fabricated with a complementary metal oxide semiconductor (CMOS) process. Unlike traditional CMOS ISFET sensors that use the Si3N4 passivation of the foundry for ion detection, the device reported here was processed with a layer of Ta2O5 that increased the detection sensitivity to 45 mV/pH unit at the sensor readout. The drift was reduced to 0.8 mV/hour with a linear pH response between pH 2 – 12. A high-speed instrumentation system capable of acquiring nearly 500 fps was developed to stream out the data. The device was then used to measure glucose concentration through the activity of hexokinase in the range of 0.05 mM – 231 mM, encompassing glucose’s physiological range in blood. Localised and temporal enzyme kinetics of hexokinase was studied in detail. These results present a roadmap towards a viable personal metabolome machine
    • …
    corecore