9 research outputs found
B-mode and Doppler ultrasonography of adrenal glands of healthy dogs
ABSTRACT The aim of this study was to determine the vascular indices of adrenal blood flow in healthy dogs (systolic velocity - SV; diastolic velocity - DV; resistance index - RI). Eighteen dogs (thirty six adrenal) were studied. Physical examination, biochemical profile and dexamethasone suppression test were performed to determine general health status. Echotexture, size, contours and margins, and overall shape of the adrenal gland (right and left) were assessed via ultrasound. By spectral Doppler of the phrenic-abdominal artery, the SV, DV, and RI were acquired. Animals did not show alterations in clinical and laboratory examination and suppression of cortisol. Normal homogeneous and echotexture, regular contours and margins and normal shape and size were verified via B mode. Spectral Doppler of the phrenic-abdominal artery showed monophasic-patterned waves and low vascular resistance and systolic peak evident with means values: left adrenal - SV = 31.34cm/s, DV = 9.54cm/s and RI = 0.69; and right adrenal - SV = 27.83cm/s, DV = 7.71cm/s and RI = 0.68. Doppler evaluation of adrenal was easily implemented and may provide base line data in the study, allowing for the use of this technique as a diagnostic tool for diseases of the dog's adrenal
Acoustic radiation force impulse (ARFI) elastography of testicular disorders in dogs: preliminary results
The aim of this study was to describe the use of acoustic radiation force impulse (ARFI) elastography in the evaluation of testicular disorders in dogs. Eighteen dogs with testicular disorders (thirty-six testicles) were assessed. Echotexture, size, contours and margins of testes were analysed by ultrasonography. Deformities and tissue stiffness (greyscale and homogenous or heterogeneous) were evaluated by qualitative elastography and shear velocity was determined quantitatively. Subsequent to orchiectomy, testicular samples were collected for histopathology analysis and thirty-six disorders were identified. Qualitative elastography revealed that normal healthy testicular tissues were homogenous and not pliable while the affected testicles had alterations in tissue stiffness and homogeneity. The values obtained for quantitative elastography of the testicular tissues were: normal/healthy - 1.30±0.12 m/s; degenerated - 0.97±0.08 m/s; atrophied - 2.00±0.35 m/s; hypoplastic - 0.82±0.2 m/s; cystic - 1.32±0.18 m/s; orchitis - 2.68±0.42 m/s; interstitial cell tumours - 3.32±0.65 m/s; sertolioma - 2.99±0.07 m/s and leydigoma - 2.73±0.37. ARFI elastography of abnormal testes proved to be an applicable and complementary technique in the diagnosis of testicular disease in dogs
Acoustic radiation force impulse (ARFI) elastography of adrenal glands in healthy adult dogs
ABSTRACT To describe the ARFI elastography in the evaluation of the adrenal glands in adult dogs, to evaluate the stiffness of adrenal parenchyma and to determine the qualitative and quantitative standards of the ARFI technique, which have not yet been described in veterinary medicine. Sixty adrenal glands from thirty healthy adult dogs were evaluated by B-mode and qualitative and quantitative ARFI elastography to assess the stiffness of healthy parenchyma and to determine the quality and quantity (shear velocity) standards of ARFI technique in body, cranial and caudal adrenal poles. Findings of ultrasonography evaluations were normal. Qualitative elastography showed that adrenal glands were not deformable and presented homogeneous middle-gray areas. The results of shear wave velocity were similar statically (P = 0.3087): 1) left adrenal - 1.42 m/s for cranial polar, 1.31 m/s for body region, and 1.71 m/s for caudal polar; 2) right adrenal - 1.42 m/s for cranial polar, 1.74 m/s for body region and 1.63 m/s for caudal pole. Quantitative and qualitative ARFI elastography of dogs' adrenal glands is feasible, well tolerated, easily implemented and may provide baseline data in the study of this structure to allow the use of ARFI
Avaliação de parâmetros cardiovasculares, ventilatórios e hemogasométricos de coelhos anestesiados com isofluorano ou sevofluorano e submetidos à ventilação espontânea ou controlada a volume
The volume-controlled mechanical ventilation and spontaneous ventilation, through haemogasometric, cardiovascular and spirometry variables were evaluated. Twenty-eight rabbits were distributed into two groups: GIVC (isoflurane and volume-controlled ventilation), GIVE (isoflurane and spontaneous ventilation), GSVC (sevoflurane and volume-controlled ventilation) and GSVE (sevoflurane and spontaneous ventilation). Induction was performed by mask with isoflurane (GIVE and GIVC) or sevoflurane (GSVE and GSVC) at 1.5 MAC in 100% oxygen. To maintain anesthesia, MAC was reset to 1. In GIVC and GSVC groups, rocuronium was administered at a dose of 0.6 mg/kg followed by its continuous infusion (0.6 mg/kg/h). In GSVE and GIVE, 0.9% NaCl was administered instead of rocuronium. Controlled ventilation was started by adjusting the capnometry in order to obtain values between 35 and 45 mmHg. Parameters were measured 60 minutes after induction of anesthesia (M0), 15 minutes after the bolus of rocuronium or 0.9% NaCl (M15) and every fifteen minutes (M30, M45 and M60). Hypercapnia and acidosis was evident in GIVC, GSVC and GSVE. We concluded that the volume-controlled mechanical ventilation was not able to maintain normocapnia in rabbits, producing acidosis in them, especially when using sevoflurane. The use of isoflurane showed greater stability than the sevoflurane anesthetic in the species studied.Avaliaram-se as ventilações mecânica controlada a volume e espontânea, por meio das variáveis hemogasométricas, cardiovasculares e ventilométricas. DistribuÃram-se 28 coelhos nos grupos: GIVC (isofluorano e ventilação controlada a volume), GIVE (isofluorano e ventilação espontânea), GSVC (sevofluorano e ventilação controlada a volume) e GSVE (sevofluorano e ventilação espontânea). Induziu-se por máscara, com isofluorano (GIVE e GIVC) ou sevofluorano (GSVE e GSVC) a 1,5 CAM, em oxigênio a 100%. Para manutenção anestésica, reajustou-se para 1 CAM. No GIVC e no GSVC, administrou-se rocurônio, na dose de 0,6mg/kg, seguida de infusão contÃnua na mesma dose de 0,6mg/kg/h. No GIVE e no GSVE, foi administrado NaCl 0,9% em vez de rocurônio. Iniciou-se a ventilação controlada ajustando-a de maneira a obter capnometria entre 35 e 45mmHg. Mensuraram-se os parâmetros 60 minutos após a indução anestésica (M0), 15 minutos após o bolus de rocurônio ou NaCl 0,9% (M15) e a cada 15 minutos (M30, M45 e M60). Evidenciou-se hipercapnia e acidose em GIVC, GSVC e GSVE. Concluiu-se que a ventilação mecânica controlada a volume não foi capaz de manter a normocapnia em coelhos, gerando acidose, principalmente quando se utilizou sevofluorano. O uso do isofluorano demonstrou maior estabilidade anestésica que o sevofluorano nesta
Surgical sponge associated with platelets rich plasma in skin mesh grafts and layer in rabbits (Oryctolagus cuniculus)
ABSTRACT The aim of this study was to evaluate of the efficacy of PRP employment associated with surgical sponges to improve the integration of the graft in the recipient bed. It was held at the Veterinary Hospital UNESP, Campus of Jaboticabal - SP, a study of 64 rabbits, divided into eight groups with eight animals. The groups were divided in control with saline solution 0,9%, control with PRP both without the sponge, surgical sponge with PRP, surgical sponge without PRP, and were used mesh and layer grafts in the respective groups. The data were submitted to statistical analysis (paired t-test, Kruskal-Wallis test, with subsequent use of the multiple comparison tests of Dunn, analysis of variance (F) test, Tukey test, P< 0.05). Edema and exudate with 3 and 3 and 7 days (P= 0,03 e P= 0,0049); coloring on the 14th day (P= 0,0001); cosmetic appearance on the 7th and 14th day (P= 0,0026 and P= 0,0001); mononuclear cells (P= 0,01) and polymorphonuclear (P= 0,01); fibroblast proliferation (P= 0,01); collagenous (P= 0,05); hemorrhage (P-007); necrosis and re-epithelialization (P= 0,2928 and P= 0,1). We concluded that the use of Platelet Rich Plasma Gel on skin grafts associated with a sponge as a compressive dressing promote the skin graft survival without a previous granulation tissue