25 research outputs found
Recommended from our members
Geothermal high temperature instrumentation applications
A quick look at the geothermal industry shows a small industry producing about $1 billion in electric sales annually. The industry is becoming older and in need of new innovative solutions to instrumentation problems. A quick look at problem areas is given along with basic instrumentation requirements. The focus of instrumentation is on high temperature electronics
Recommended from our members
Core-tube data logger
Wireline core drilling, increasingly used for geothermal exploration, employs a core-tube to capture a rock core sample during drilling. Three types of core-tube data loggers (CTDL) have been built and tested to date by Sandia national Laboratories. They are: (1) temperature-only logger, (2) temperature/inclinometer logger and (3) heat-shielded temperature/inclinometer logger. All were tested during core drilling operations using standard wireline diamond core drilling equipment. While these tools are designed for core-tube deployment, the tool lends itself to be adapted to other drilling modes and equipment. Topics covered in this paper include: (1) description on how the CTDLs are implemented, (2) the components of the system, (3) the type of data one can expect from this type of tool, (4) lessons learned, (5) comparison to its counterpart and (6) future work
A terminal assessment of stages theory : introducing a dynamic states approach to entrepreneurship
Stages of Growth models were the most frequent theoretical approach to understanding entrepreneurial business growth from 1962 to 2006; they built on the growth imperative and developmental models of that time. An analysis of the universe of such models (N=104) published in the management literature shows no consensus on basic constructs of the approach, nor is there any empirical confirmations of stages theory. However, by changing two propositions of the stages models, a new dynamic states approach is derived. The dynamic states approach has far greater explanatory power than its precursor, and is compatible with leading edge research in entrepreneurship
Recommended from our members
High temperature spectral gamma well logging
A high temperature spectral gamma tool has been designed and built for use in small-diameter geothermal exploration wells. Several engineering judgments are discussed regarding operating parameters, well model selection, and signal processing. An actual well log at elevated temperatures is given with spectral gamma reading showing repeatability
Recommended from our members
Precision pressure/temperature logging tool
Past memory logging tools have provided excellent pressure/temperature data when used in a geothermal environment, and they are easier to maintain and deploy than tools requiring an electric wireline connection to the surface. However, they are deficient since the tool operator is unaware of downhole conditions that could require changes in the logging program. Tools that make ``decisions`` based on preprogrammed scenarios can partially overcome this difficulty, and a suite of such memory tools has been developed at Sandia National Laboratories. The first tool, which forms the basis for future instruments, measures pressure and temperature. Design considerations include a minimization of cost while insuring quality data, size compatibility with diamond-cored holes, operation in holes to 425 C (800 F), transportability by ordinary passenger air service, and ease of operation. This report documents the development and construction of the pressure/temperature tool. It includes: (1) description of the major components; (2) calibration; (3) typical logging scenario; (4) tool data examples; and (5) conclusions. The mechanical and electrical drawings, along with the tool`s software, will be furnished upon request
Coding of position by simultaneously recorded sensory neurones in the cat dorsal root ganglion
Muscle, cutaneous and joint afferents continuously signal information about the position and movement of individual joints. How does the nervous system extract more global information, for example about the position of the foot in space? To study this question we used microelectrode arrays to record impulses simultaneously from up to 100 discriminable nerve cells in the L6 and L7 dorsal root ganglia (DRG) of the anaesthetized cat. When the hindlimb was displaced passively with a random trajectory, the firing rate of the neurones could be predicted from a linear sum of positions and velocities in Cartesian (x, y), polar or joint angular coordinates. The process could also be reversed to predict the kinematics of the limb from the firing rates of the neurones with an accuracy of 1–2 cm. Predictions of position and velocity could be combined to give an improved fit to limb position. Decoders trained using random movements successfully predicted cyclic movements and movements in which the limb was displaced from a central point to various positions in the periphery. A small number of highly informative neurones (6–8) could account for over 80% of the variance in position and a similar result was obtained in a realistic limb model. In conclusion, this work illustrates how populations of sensory receptors may encode a sense of limb position and how the firing of even a small number of neurones can be used to decode the position of the limb in space