8,855 research outputs found

    Performance of the OPAL Si-W luminometer at LEP I-II

    Full text link
    A pair of compact Silicon-Tungsten calorimeters was operated in the OPAL experiment at LEP to measure the integrated luminosity from detection of Bhabha electrons scattered at angles between 25 and 58 mrad from the beam line. In the eight years from 1993 to 2000 the detector worked first at the Z mass peak and then at center of mass energies up to 209 GeV. The fine radial and longitudinal segmentation (2.5mm x 1X0) allowed the radial position of electron and photon showers to be measured with a resolution of 130-170 microns and a residual radial bias as small as 7 microns. Reducing the bias in the definition of the inner acceptance radius was the key element in obtaining an experimental systematic error on the integrated luminosity of only 3.4 10^-4. The performance of the detector at both LEP-I and LEP-II is reviewed. Energy resolution, sensitivity to overlapping electromagnetic showers and sensitivity to minimum ionizing particles are discussed.Comment: 9 pages, 7 figures, 10th International Conference on Calorimetry in High Energy Physics. http://3w.hep.caltech.edu/calor02

    Nonlocal Gravity: Modified Poisson's Equation

    Full text link
    The recent nonlocal generalization of Einstein's theory of gravitation reduces in the Newtonian regime to a nonlocal and nonlinear modification of Poisson's equation of Newtonian gravity. The nonlocally modified Poisson equation implies that nonlocality can simulate dark matter. Observational data regarding dark matter provide limited information about the functional form of the reciprocal kernel, from which the original nonlocal kernel of the theory must be determined. We study this inverse problem of nonlocal gravity in the linear domain, where the applicability of the Fourier transform method is critically examined and the conditions for the existence of the nonlocal kernel are discussed. This approach is illustrated via simple explicit examples for which the kernels are numerically evaluated. We then turn to a general discussion of the modified Poisson equation and present a formal solution of this equation via a successive approximation scheme. The treatment is specialized to the gravitational potential of a point mass, where in the linear regime we recover the Tohline-Kuhn approach to modified gravity.Comment: 27 pages, 4 figures; v2: minor improvements, accepted for publication in J. Math. Phy

    Relative Density, Equilibrium Moisture Content, and Dimensional Stability of Western Hemlock Bark

    Get PDF
    The measurement of western hemlock bark samples from three coastal sites in British Columbia revealed that inner bark relative density (0.382) is less than that of the adjacent sapwood (0.413) and markedly less than that of outer bark (0.463). The equilibrium moisture content of the inner and outer bark are equivalent at both 70 and 30% relative humidity, and slightly higher than that of the sapwood.The generally higher shrinkage of bark compared with wood is the result of bark cell collapse during drying. In the outer bark, some collapse or crushing takes place in the standing tree. This compacting of tissue reduces the shrinkage of outer bark relative to the inner bark. The actual shrinkage per unit change in moisture content of the inner bark is the same as that for the sapwood. The outer bark appears to be more dimensionally stable. The longitudinal shrinkage of both inner (2.9%) and outer (2.2%) bark is markedly greater than that of the sapwood (0.1-0.2%)

    The Character of Z-pole Data Constraints on Standard Model Parameters

    Full text link
    Despite the impressive precision of the Z-pole measurements made at LEP and SLC, the allowed region for the principle Standard Model parameters responsible for radiative corrections (the mass of the Higgs, the mass of the top and alpha(Mz)) is still large enough to encompass significant non-linearities. The nature of the experimental constraints therefore depends in an interesting way on the "accidental" relationships among the various measurements. In particular, the fact that the Z-pole measurements favor values of the Higgs mass excluded by direct searches leads us to examine the effects of external Higgsstrahlung, a process ignored by the usual precision electroweak calculations.Comment: 9 pages, 6 figures, REVTeX format; added reference in section IV; added paragraph on widths and a few cosmetic changes to correspond to published versio

    Bark-Tissue Thickness of Coastal Western Hemlock in British Columbia

    Get PDF
    Bark-tissue thicknesses of coastal western hemlock are reported. Variation in these characteristics is considered between sites, trees, and height positions. Total bark thickness did not vary significantly with site, averaging 7.4 mm, 12.2 mm, and 12.6 mm for the top, middle, and butt height positions, respectively. However, the relative contribution of the individual tissues to the total thickness did vary with site. The thickness of all bark characteristics varied with height, being least at the top position, but differing very little between middle and butt positions

    A Mechanistic Approach to Crystallite Length as Related to Cell-Wall Structure

    Get PDF
    A tentative mechanistic model is proposed that relates variation in crystallite length in wood to some physical conditions under which the crystallite may have been formed, namely the curvature and ultrastructure of the microfibril. Over most of the experimental data range, representing both hardwood and softwood samples, the model allows reasonably good prediction of the effect of crystallite orientation angle and radial distance from the cell center. As the angle increases and radial distance decreases, the average crystallite length becomes smaller

    The X-ray R Aquarii: A Two-sided Jet and Central Source

    Full text link
    We report Chandra ACIS-S3 x-ray imaging and spectroscopy of the R Aquarii binary system that show a spatially resolved two-sided jet and an unresolved central source. This is the first published report of such an x-ray jet seen in an evolved stellar system comprised of ~2-3 solar masses. At E < 1 keV, the x-ray jet extends both to the northeast and southwest relative to the central binary system. At 1 < E < 7.1 keV, R Aqr is a point-like source centered on the star system. While both 3.5-cm radio continuum emission and x-ray emission appear coincident in projection and have maximum intensities at ~7.5" northeast of the central binary system, the next strongest x-ray component is located \~30" southwest of the central binary system and has no radio continuum counterpart. The x-ray jets are likely shock heated in the recent past, and are not in thermal equilibrium. The strongest southwest x-ray jet component may have been shocked recently since there is no relic radio emission as expected from an older shock. At the position of the central binary, we detect x-ray emission below 1.6 keV consistent with blackbody emission at T ~2 x 10^6 K. At the central star there is also a prominent 6.4 keV feature, a possible fluorescence or collisionally excited Fe K-alpha line from an accretion disk or from the wind of the giant star. For this excitation to occur, there must be an unseen hard source of x-rays or particles in the immediate vicinity of the hot star. Such a source would be hidden from view by the surrounding edge-on accretion disk.Comment: PS, 20 pages, including 3 figures PNG, JPG - accepted for publication in ApJ Letters. Subject headings: stars: individual (R Aquarii) -- binaries: symbiotic -- circumstellar matter -- stars: white dwarfs -- stars: winds, outflows -- radio continuum: stars -- x-rays: genera

    The Study of the Pioneer Anomaly: New Data and Objectives for New Investigation

    Full text link
    Radiometric tracking data from Pioneer 10 and 11 spacecraft has consistently indicated the presence of a small, anomalous, Doppler frequency drift, uniformly changing with a rate of ~6 x 10^{-9} Hz/s; the drift can be interpreted as a constant sunward acceleration of each particular spacecraft of a_P = (8.74 \pm 1.33) x 10^{-10} m/s^2. This signal is known as the Pioneer anomaly; the nature of this anomaly remains unexplained. We discuss the efforts to retrieve the entire data sets of the Pioneer 10/11 radiometric Doppler data. We also report on the recently recovered telemetry files that may be used to reconstruct the engineering history of both spacecraft using original project documentation and newly developed software tools. We discuss possible ways to further investigate the discovered effect using these telemetry files in conjunction with the analysis of the much extended Doppler data. We present the main objectives of new upcoming study of the Pioneer anomaly, namely i) analysis of the early data that could yield the direction of the anomaly, ii) analysis of planetary encounters, that should tell more about the onset of the anomaly, iii) analysis of the entire dataset, to better determine the anomaly's temporal behavior, iv) comparative analysis of individual anomalous accelerations for the two Pioneers, v) the detailed study of on-board systematics, and vi) development of a thermal-electric-dynamical model using on-board telemetry. The outlined strategy may allow for a higher accuracy solution for a_P and, possibly, will lead to an unambiguous determination of the origin of the Pioneer anomaly.Comment: 43 pages, 40 figures, 3 tables, minor changes before publicatio

    VETA-I x ray test analysis

    Get PDF
    This interim report presents some definitive results from our analysis of the VETA-I x-ray testing data. It also provides a description of the hardware and software used in the conduct of the VETA-I x-ray test program performed at the MSFC x-ray Calibration Facility (XRCF). These test results also serve to supply data and information to include in the TRW final report required by DPD 692, DR XC04. To provide an authoritative compendium of results, we have taken nine papers as published in the SPIE Symposium, 'Grazing Incidence X-ray/EUV Optics for Astronomy and Projection Lithography' and have reproduced them as the content of this report

    The x ray reflectivity of the AXAF VETA-I optics

    Get PDF
    The x-ray reflectivity of the VETA-I optic, the outermost shell of the AXAF x-ray telescope, with a bare Zerodur surface, is measured and compared with theoretical predictions. Measurements made at energies of 0.28, 0.9, 1.5, 2.1, and 2.3 keV are compared with predictions based on ray trace calculations. The data were obtained at the x-ray calibrations facility at Marshall Space Flight Center with an electron impact x-ray source located 528 m from the grazing incidence mirror. The source used photoelectric absorption filters to eliminate bremsstrahlung continuum. The mirror has a diameter of 1.2 m and a focal length of 10 m. The incident and reflected x-ray flux are detected using two proportional counters, one located in the incident beam of x-rays at the entrance aperture of the VETA-I, and the other in the focal plane behind an aperture of variable size. Results on the variation of the reflectivity with energy as well as the absolute value of the reflectivity are presented. We also present a synchrotron reflectivity measurement with high energy resolution over the range 0.26 to 1.8 keV on a flat Zerodur sample, done at NSLS. We present evidence for contamination of the flat by a thin layer of carbon on the surface, and the possibility of alteration of the surface composition of the VETA-I mirror perhaps by the polishing technique. The overall agreement between the measured and calculated effective area of VETA-I is between 2.6 percent and 10 percent, depending on which model for the surface composition is adopted. Measurements at individual energies deviate from the best-fitting calculation to 0.3 to 0.8 percent, averaging 0.6 percent at energies below the high energy cutoff of the mirror reflectivity, and are as high as 20.7 percent at the cutoff. We also discuss the approach to the final preflight calibration of the full AXAF flight mirror
    corecore