747 research outputs found
Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study
Background Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. Methods In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. Results The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Conclusions Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complication
Ultrasound-guided spermatic cord block for scrotal surgery
Background Performing spermatic cord block for scrotal surgery avoids the potential risks of neuraxial and general anaesthesia and provides long-lasting postoperative analgesia. A blindly performed block is often inefficient and bears its own potential risks (intravascular injection of local anaesthetics, haematoma formation and perforation of the deferent duct). The use of ultrasound may help to overcome these disadvantages. The aim of this study was to test the feasibility and monitor the success rate of a new ultrasound-guided spermatic cord block. Methods Twenty consecutive patients undergoing urologic surgery (subcapsular orchiectomy or vaso-vasostomy) were included in this prospective study. Using a linear ultrasound probe, the spermatic cord was identified by locating the spermatic artery and the deferent duct. A 23 G Microlance needle was advanced close to the deferent duct by avoiding vessel perforation, and local anaesthetic was deposited around the deferent duct under direct visualization. The primary outcome was the success rate of the block which was defined as surgery without any substitution of opioids, additional local anaesthetics, or sedatives. Results In 20 patients, 40 blocks were performed with a success rate of 95% (n=38). The failure rate was 5% (n=2) and no conversion to general anaesthesia was needed. The mean duration of the block was 14.1 h (sd 6.9). Conclusions The use of ultrasound guidance to perform spermatic cord block is feasible and has a high success rate. Our new approach may become a suitable alternative to neuraxial or general anaesthesia especially in the ambulatory surgical setting. Registry: International Standard Randomised Controlled Trial Number Register; www.controlled-trials.com; Registry Nr.: ISRCTN4464781
Different Learning Curves for Axillary Brachial Plexus Block: Ultrasound Guidance versus Nerve Stimulation
Little is known about the learning of the skills needed to perform ultrasound- or nerve stimulator-guided peripheral nerve blocks. The aim of this study was to compare the learning curves of residents trained in ultrasound guidance versus residents trained in nerve stimulation for axillary brachial plexus block. Ten residents with no previous experience with using ultrasound received ultrasound training and another ten residents with no previous experience with using nerve stimulation received nerve stimulation training. The novices' learning curves were generated by retrospective data analysis out of our electronic anaesthesia database. Individual success rates were pooled, and the institutional learning curve was calculated using a bootstrapping technique in combination with a Monte Carlo simulation procedure. The skills required to perform successful ultrasound-guided axillary brachial plexus block can be learnt faster and lead to a higher final success rate compared to nerve stimulator-guided axillary brachial plexus block
Ultrasound-guided paravertebral puncture and placement of catheters in human cadavers: an imaging study
Background During paravertebral block, the anterolateral limit of the paravertebral space, which consists of the pleura, should preferably not be perforated. Also it is possible that, during the block, the constant superior costotransverse ligament can be missed in the loss-of-resistance technique. We therefore aimed to develop a new technique for an ultrasound-guided puncture of the paravertebral space. Methods We performed 20 punctures and catheter placements in 10 human cadavers. A sonographic view showing the pleura and the superior costotransverse ligament was obtained with a slightly oblique scan using a curved array transducer. After inline approach, injection of 10 ml normal saline confirmed the correct position of the needle tip, distended the space, and enabled catheter insertion. The spread of contrast dye injected through the catheters was assessed by CT scans. Results The superior costotransverse ligament and the paravertebral space were easy to identify. The needle tip reached the paravertebral space without problems under visualization. In contrast, the introduction of the catheter was difficult. The CT scan revealed a correct paravertebral spread of contrast in 11 cases. Out of the remaining, one catheter was found in the pleural space, in six cases there was an epidural, and in two cases there was a prevertebral spread of contrast dye. Conclusions We successfully developed a technique for an accurate ultrasound-guided puncture of the paravertebral space. We also showed that when a catheter is introduced through the needle with the tip lying in the paravertebral space, there is a high probability of catheter misplacement into the epidural, mediastinal, or pleural space
Ultrasound-guided thoracic paravertebral puncture and placement of catheters in human cadavers: where do catheters go?â
Background Paravertebral regional anaesthesia is used to treat pain after several surgical procedures. This study aimed to improve on our first published ultrasound-guided approach to the paravertebral space (PVS) and to investigate a possible discrepancy between the needle, catheter, and contrast dye position. Methods In 10 cadavers, we conducted 26 ultrasound-guided paravertebral approaches combined with loss of resistance (LOR) and after an interim analysis performed 36 novel, pure ultrasound-guided (PUSG) paravertebral approaches. Needle-tip position was controlled by a first computed tomography (CT) scan. After placement of the catheters, the tips were assessed by a second CT and the spread of injected contrast dye was assessed by further CT scans. The part of the PVS near the intervertebral foramen was defined as the primary target to reach. Results The first CT scans assessing 62 needle tips revealed that: 13 (50%) of LOR and 34 (94%) of PUSG approaches were at the target; and two (8%) LOR and no PUSG approaches were outside the PVS. With the second CT scans 60 catheter-tip positions were analysed: three (12%) of LOR and five (14%) of PUSG approaches were at the target, three (12%) of LOR and two (6%) of PUSG approaches were outside the PVS. No catheters were detected in the epidural space. In two cases, insertion of the catheter was not possible. In cases with major epidural contrast, the widest contrast dye spread was 7.7 (3.5) [mean (sd)] vertebral segments. Conclusions Our new PUSG technique has a high success rate for paravertebral needle placement. Although needles were correctly positioned, catheters were usually found distant from the needle-tip positio
Ultrasound-guided percutaneous tracheal puncture: a computer-tomographic controlled study in cadavers
Background Ultrasound-guided techniques are increasingly used in anaesthetic practice to identify tissues beneath the skin and to increase the accuracy of placement of needles close to targeted structures. To examine ultrasound's usefulness for dilatational tracheostomy, we performed ultrasound-guided tracheal punctures in human cadavers followed by computer-tomographic (CT) control. Methods The trachea of nine cadavers was punctured using an in-plane approach with a longitudinal ultrasound visualization of the trachea. As soon as a loss of resistance was felt, or air/fluid could be aspirated into the attached syringe, the syringe was disconnected and the ultrasound transducer set aside. Thereafter, a cricothyroidotomy guidewire was inserted through the needle into the trachea. The needle was then removed, leaving the wire in place and a control CT imaging of the neck and the chest was performed. Primary outcome was successful wire insertion into the trachea. Results Tracheal puncture and wire insertion was successful in eight of nine cadavers at the first attempt and in one at the second attempt (total of 10 puncture attempts, nine successful). In eight of nine successfully inserted wires, the wire was placed on the defined midline. Conclusions Ultrasound guidance can facilitate successful tracheal puncture. However, combining an in-plane approach with a longitudinal ultrasound visualization of the trachea neither guarantees an exact midline puncture nor allows detection of a misplaced guidewir
Electric field dependence of thermal conductivity of a granular superconductor: Giant field-induced effects predicted
The temperature and electric field dependence of electronic contribution to
the thermal conductivity (TC) of a granular superconductor is considered within
a 3D model of inductive Josephson junction arrays. In addition to a
low-temperature maximum of zero-field TC K(T,0) (controlled by mutual
inductance L_0 and normal state resistivity R_n), the model predicts two major
effects in applied electric field: (i) decrease of the linear TC, and (ii)
giant enhancement of the nonlinear (i.e., grad T-dependent) TC with
[K(T,E)-K(T,0)]/K(T,0) reaching 500% for parallel electric fields E=E_T
(E_T=S_0|grad T| is an "intrinsic" thermoelectric field). A possiblity of
experimental observation of the predicted effects in granular superconductors
is discussed.Comment: 5 LaTeX pages (jetpl.sty included), 2 EPS figures. To be published in
JETP Letter
Multi-species integrative biclustering
We describe an algorithm, multi-species cMonkey, for the simultaneous biclustering of heterogeneous multiple-species data collections and apply the algorithm to a group of bacteria containing Bacillus subtilis, Bacillus anthracis, and Listeria monocytogenes. The algorithm reveals evolutionary insights into the surprisingly high degree of conservation of regulatory modules across these three species and allows data and insights from well-studied organisms to complement the analysis of related but less well studied organisms
Diluted Josephson-junction arrays in a magnetic field: phase coherence and vortex glass thresholds
The effects of random dilution of junctions on a two-dimensional
Josephson-junction array in a magnetic field are considered. For rational
values of the average flux quantum per plaquette , the superconducting
transition temperature vanishes, for increasing dilution, at a critical value
, while the vortex ordering remains stable up to , much
below the value corresponding to the geometric percolation threshold. For
, the array behaves as a zero-temperature vortex-glass.
Numerical results for from defect energy calculations are presented
which are consistent with this scenario.Comment: 4 pages, 4 figures, to appear in Phys. Rev.
- âŚ