50 research outputs found

    Low-Frequency Radio Transients in the Galactic Center

    Get PDF
    We report the detection of a new radio transient source, GCRT J1746-2757, located only 1.1 degrees north of the Galactic center. Consistent with other radio transients toward the Galactic center, this source brightened and faded on a time scale of a few months. No X-ray counterpart was detected. We also report new 0.33 GHz measurements of the radio counterpart to the X-ray transient source, XTE J1748-288, previously detected and monitored at higher radio frequencies. We show that the spectrum of XTE J1748-288 steepened considerably during a period of a few months after its peak. We also discuss the need for a more efficient means of finding additional radio transients

    A primary care, multi-disciplinary disease management program for opioid-treated patients with chronic non-cancer pain and a high burden of psychiatric comorbidity

    Get PDF
    BACKGROUND: Chronic non-cancer pain is a common problem that is often accompanied by psychiatric comorbidity and disability. The effectiveness of a multi-disciplinary pain management program was tested in a 3 month before and after trial. METHODS: Providers in an academic general medicine clinic referred patients with chronic non-cancer pain for participation in a program that combined the skills of internists, clinical pharmacists, and a psychiatrist. Patients were either receiving opioids or being considered for opioid therapy. The intervention consisted of structured clinical assessments, monthly follow-up, pain contracts, medication titration, and psychiatric consultation. Pain, mood, and function were assessed at baseline and 3 months using the Brief Pain Inventory (BPI), the Center for Epidemiological Studies-Depression Scale scale (CESD) and the Pain Disability Index (PDI). Patients were monitored for substance misuse. RESULTS: Eighty-five patients were enrolled. Mean age was 51 years, 60% were male, 78% were Caucasian, and 93% were receiving opioids. Baseline average pain was 6.5 on an 11 point scale. The average CESD score was 24.0, and the mean PDI score was 47.0. Sixty-three patients (73%) completed 3 month follow-up. Fifteen withdrew from the program after identification of substance misuse. Among those completing 3 month follow-up, the average pain score improved to 5.5 (p = 0.003). The mean PDI score improved to 39.3 (p < 0.001). Mean CESD score was reduced to 18.0 (p < 0.001), and the proportion of depressed patients fell from 79% to 54% (p = 0.003). Substance misuse was identified in 27 patients (32%). CONCLUSIONS: A primary care disease management program improved pain, depression, and disability scores over three months in a cohort of opioid-treated patients with chronic non-cancer pain. Substance misuse and depression were common, and many patients who had substance misuse identified left the program when they were no longer prescribed opioids. Effective care of patients with chronic pain should include rigorous assessment and treatment of these comorbid disorders and intensive efforts to insure follow up

    A double-blind, randomized, multicenter, Italian study of frovatriptan versus almotriptan for the acute treatment of migraine

    Get PDF
    The objective of this study was to evaluate patients’ satisfaction with acute treatment of migraine with frovatriptan or almotriptan by preference questionnaire. One hundred and thirty three subjects with a history of migraine with or without aura (IHS 2004 criteria), with at least one migraine attack in the preceding 6 months, were enrolled and randomized to frovatriptan 2.5 mg or almotriptan 12.5 mg, treating 1–3 attacks. The study had a multicenter, randomized, double blind, cross-over design, with treatment periods lasting <3 months. At study end patients assigned preference to one of the treatments using a questionnaire with a score from 0 to 5 (primary endpoint). Secondary endpoints were pain free and pain relief episodes at 2 and 4 h, and recurrent and sustained pain free episodes within 48 h. Of the 133 patients (86%, intention-to-treat population) 114 of them expressed a preference for a triptan. The average preference score was not significantly different between frovatriptan (3.1 ± 1.3) and almotriptan (3.4 ± 1.3). The rates of pain free (30% frovatriptan vs. 32% almotriptan) and pain relief (54% vs. 56%) episodes at 2 h did not significantly differ between treatments. This was the case also at 4 h (pain free: 56% vs. 59%; pain relief: 75% vs. 72%). Recurrent episodes were significantly (P < 0.05) less frequent under frovatriptan (30% vs. 44%), also for the attacks treated within 30 min. No significant differences were observed in sustained pain free episodes (21% vs. 18%). The tolerability profile was similar between the two drugs. In conclusion, our study suggests that frovatriptan has a similar efficacy of almotriptan in the short-term, while some advantages are observed during long-term treatment

    Ring Expansion of Cyclobutylmethylcarbenium Ions to Cyclopentane or Cyclopentene Derivatives and Metal-Promoted Analogous Rearrangements

    Full text link

    Automatic gravure print feature determination at production speeds.

    Get PDF
    This paper describes the development of a non-contact system for measuring the colour of printed material at web speeds, in addition to gravure-printed dot feature recognition. The system proposed uses a non-contact spectrophotometer based on a holographic grating, in conjunction with a conventional monochrome area scan camera, from which colour spectral data are extracted, while a xenon flash is used to illuminate colour samples. Dot features are captured by a magnification lens, in conjunction with a progressive scan camera. Software and hardware details of the system are given, together with the underlying mathematics for colour space conversion and measurement. Conversion equations from X, Y, Z chromaticity coordinates to the RGB system are presented, and also equations to convert from the L*a*b* colour space to X, Y, Z chromaticity coordinates. Experimental results are presented whereby the non-contact spectral system is shown to perform to a colour tolerance exceeding that of conventional colour video systems, and where performance of the dot feature system is comparable with traditional static examination methods using a microscope
    corecore