133 research outputs found

    Hardware for digitally controlled scanned probe microscopes

    Get PDF
    The design and implementation of a flexible and modular digital control and data acquisition system for scanned probe microscopes (SPMs) is presented. The measured performance of the system shows it to be capable of 14-bit data acquisition at a 100-kHz rate and a full 18-bit output resolution resulting in less than 0.02-Å rms position noise while maintaining a scan range in excess of 1 µm in both the X and Y dimensions. This level of performance achieves the goal of making the noise of the microscope control system an insignificant factor for most experiments. The adaptation of the system to various types of SPM experiments is discussed. Advances in audio electronics and digital signal processors have made the construction of such high performance systems possible at low cost

    Float-polishing process and analysis of float-polished quartz

    Get PDF
    A fluid-mechanical model is developed for the float-polishing process. In this model laminar flow between the sample and the lap results in pressure gradients at the grooves that support the sample on a fluid layer. The laminar fluid motion also produces supersmooth, damage-free surfaces. Quartz substrates for applications in high-stress environments were float polished, and their surfaces were analyzed by optical scatterometry, photoacoustic spectroscopy, and atomic force microscopy. The removal of 100 µm of material by a lapping-polishing process, with final float polishing, left low levels of subsurface damage, with a surface roughness of approximately 0.2-nm rms

    Postmortem Analyses Unveil the Poor Efficacy of Decontamination, Anti-Inflammatory and Immunosuppressive Therapies in Paraquat Human Intoxications

    Get PDF
    studies resulting from human PQ poisonings have assessed the relationship of these therapeutic measures with PQ toxicokinetics and related histopathological lesions, these being the aims of the present study.For that purpose, during 2008, we collected human fluids and tissues from five forensic autopsies following fatal PQ poisonings. PQ levels were measured by gas chromatography-ion trap mass spectrometry. Structural inflammatory lesions were evaluated by histological and immunohistochemistry analysis. The samples of cardiac blood, urine, gastric and duodenal wall, liver, lung, kidney, heart and diaphragm, showed quantifiable levels of PQ even at 6 days post-intoxication. Structural analysis showed diffused necrotic areas, intense macrophage activation and leukocyte infiltration in all analyzed tissues. By immunohistochemistry it was possible to observe a strong nuclear factor kappa-B (NF-κB) activation and excessive collagen deposition.Considering the observed PQ levels in all analyzed tissues and the expressive inflammatory reaction that ultimately leads to fibrosis, we conclude that the therapeutic protocol usually performed needs to be reviewed, in order to increase the efficacy of PQ elimination from the body as well as to diminish the inflammatory process
    • …
    corecore