53 research outputs found

    Sirolimus attenuates disease progression in an orthologous mouse model of human autosomal dominant polycystic kidney disease

    Get PDF
    In autosomal dominant polycystic kidney disease (ADPKD), abnormal proliferation of tubular cells drives cyst development and growth. Sirolimus, an inhibitor of the protein kinase mammalian target of rapamycin (mTOR) and a potent anti-proliferative agent, decreases cyst growth in several genetically distinct rodent models of polycystic kidney disease (PKD). We determined here the effect of sirolimus on renal cyst growth in Pkd2WS25/− mice; an ortholog of human ADPKD involving mutation of the Pkd2 gene. In Pkd2WS25/− mice treated with sirolimus, both the two kidney/total body weight (2K/TBW) ratio and the cyst volume density (CVD) were significantly decreased by over half compared with untreated mice suffering with PKD. However, there was no effect on the increased blood urea nitrogen (BUN) levels as an index of kidney function. There are two distinct complexes containing mTOR depending on its binding partners: mTORC1 and mTORC2. Western blot analysis of whole kidney lysates and immunohistochemistry of the cysts found that phospho-S6 ribosomal protein, a marker of mTORC1 activity, was increased in Pkd2WS25/− mice and its phosphorylation was decreased by sirolimus treatment. Phospho-Akt at serine 473, a marker associated with mTORC2 activity, was not different between Pkd2WS25/− mice and normal littermate controls. Hence, our study found that inhibition of mTORC1 by sirolimus correlated with decreased renal cyst growth in this model of human ADPKD but had no effect on the decline in renal function

    Regulated ion transport in mouse liver cyst epithelial cells

    Get PDF
    AbstractDerived from bile duct epithelia (BDE), secretion by liver cyst-lining epithelia is positioned to drive cyst expansion but the responsible ion flux pathways have not been characterized. Cyst-lining epithelia were isolated and cultured into high resistance monolayers to assess the ion secretory pathways. Electrophysiologic studies showed a marked rate of constitutive transepithelial ion transport, including Cl− secretion and Na+ absorption. Na+ absorption was amiloride-sensitive, suggesting the activation of epithelial sodium channels (ENaC). Further, both cAMPi and extracellular ATP induced robust secretory responses. Western blotting and immunohistologic analysis of liver cyst epithelia demonstrated expression of P2X4, a potent purinergic receptor in normal BDE. Luminometry and bioassaying measured physiologically relevant levels of ATP in a subset of liver cyst fluid samples. Liver cyst epithelia also displayed a significant capacity to degrade extracellular ATP. In conclusion, regulated ion transport pathways are present in liver cyst epithelia and are positioned to direct fluid secretion into the lumen of liver cysts and promote increases in liver cyst expansion and growth

    Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: A cost analysis study and prospective comparison with computed tomography scan

    Get PDF
    ObjectiveEarly in our experience with endovascular aortic aneurysm repair (EVAR) we performed both serial computed tomography scans and duplex ultrasound (DU) imaging in our post-EVAR surveillance regimen. Later we conducted a prospective study with DU imaging as the sole surveillance study and determined cost savings and outcome using this strategy.MethodsFrom September 21, 1998, to May 30, 2008, 250 patients underwent EVAR at our hospital. Before July 1, 2004, EVAR patients underwent CT and DU imaging performed every 6 months during the first year and then annually if no problems were identified (group 1). We compared aneurysm sac size, presence of endoleak, and graft patency between the two scanning modalities. After July 1, 2004, patients underwent surveillance using DU imaging as the sole surveillance study unless a problem was detected (group 2). CT and DU imaging charges for each regimen were compared using our 2008 health system pricing and Medicare reimbursements. All DU examinations were performed in our accredited noninvasive vascular laboratory by experienced technologists. Statistical analysis was performed using Pearson correlation coefficient.ResultsDU and CT scans were equivalent in determining aneurysm sac diameter after EVAR (P < .001). DU and CT were each as likely to falsely suggest an endoleak when none existed and were as likely to miss an endoleak. Using DU imaging alone would have reduced cost of EVAR surveillance by 29% (534,356)ingroup1.Costsavingsof534,356) in group 1. Cost savings of 1595 per patient per year were realized in group 2 by eliminating CT scan surveillance. None of the group 2 patients sustained an adverse event such as rupture, graft migration, or limb occlusion as a result of having DU imaging performed as the sole follow-up modality.ConclusionSurveillance of EVAR patients can be performed accurately, safely, and cost-effectively with DU as the sole imaging study

    Search for gravitational-lensing signatures in the full third observing run of the LIGO-Virgo network

    Get PDF
    Gravitational lensing by massive objects along the line of sight to the source causes distortions of gravitational wave-signals; such distortions may reveal information about fundamental physics, cosmology and astrophysics. In this work, we have extended the search for lensing signatures to all binary black hole events from the third observing run of the LIGO--Virgo network. We search for repeated signals from strong lensing by 1) performing targeted searches for subthreshold signals, 2) calculating the degree of overlap amongst the intrinsic parameters and sky location of pairs of signals, 3) comparing the similarities of the spectrograms amongst pairs of signals, and 4) performing dual-signal Bayesian analysis that takes into account selection effects and astrophysical knowledge. We also search for distortions to the gravitational waveform caused by 1) frequency-independent phase shifts in strongly lensed images, and 2) frequency-dependent modulation of the amplitude and phase due to point masses. None of these searches yields significant evidence for lensing. Finally, we use the non-detection of gravitational-wave lensing to constrain the lensing rate based on the latest merger-rate estimates and the fraction of dark matter composed of compact objects

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Search for eccentric black hole coalescences during the third observing run of LIGO and Virgo

    Get PDF
    Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass M&gt;70 M⊙) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities 0&lt;e≤0.3 at 0.33 Gpc−3 yr−1 at 90\% confidence level

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM
    corecore