32,000 research outputs found

    High resolution thermal infrared mapping of Martian channels

    Get PDF
    Viking Infrared Thermal Mapper (IRTM) high resolution (2 to 5 km) data were compiled and compared to Viking Visual Imaging Subsystem (VIS) data and available 1:5M geologic maps for several Martian channels including Dao, Harmakhis, Mangala, Shalbatana, and Simud Valles in an effort to determine the surface characteristics and the processes active during and after the formation of these channels. Results show a dominance of aeolian processes active in and around the channels. These processes have left materials thick enough to mask any genuine channel deposits. Results also indicate that very comparable Martian channels and their surrounding terrain are blanketed by deposits which are homogeneous in their thermal inertia values. However, optimum IRTM data does not cover the entire Martian surface and because local deposits of high thermal inertia material may not be large enough in areal extent or may be in an unfavorable location on the planet, a high resolution data track may not always occur over these deposits. Therefore, aeolian processes may be even more active than the IRTM data tracts can always show

    Experiments on Jet Flows and Jet Noise Far- Field Spectra and Directivity Patterns

    Get PDF
    Jet flows and jet noise far-field spectral and direction pattern

    Characterization of surficial units on Mars using Viking orbiter multispectral image and thermal data

    Get PDF
    Albedo and thermal property correlations of the topography of Mars were conducted with emphases upon the types and origins of materials exposed in the central equatorial region. This area displays a wide variation in color, albedo and thermal properties, and is relatively free of dust and haze. The physical, mineralogical and elemental characteristics of this area are discussed

    Capsule system advanced development sterilization program

    Get PDF
    Capsule system advanced development sterilization program for Mars 71 lande

    Comment on "Formation of primordial black holes by cosmic strings"

    Full text link
    We show that in a pioneering paper by Polnarev and Zembowicz, some conclusions concerning the characteristics of the Turok-strings are generally not correct. In addition we show that the probability of string collapse given there, is off by a large prefactor (~1000).Comment: 5 pages, LaTeX and 1 figure, postscript. To appear in PR

    Data management study, volume 5. Appendix J - Contractor data package procurement and contracting /PC/ Final report

    Get PDF
    Contractor data package for administration of procurement and contracting of Voyager spacecraft system

    Testing strong line metallicity diagnostics at z~2

    Full text link
    High-z galaxy gas-phase metallicities are usually determined through observations of strong optical emission lines with calibrations tied to the local universe. Recent debate has questioned if these calibrations are valid in the high-z universe. We investigate this by analysing a sample of 16 galaxies at z~2 available in the literature, and for which the metallicity can be robustly determined using oxygen auroral lines. The sample spans a redshift range of 1.4 < z < 3.6, has metallicities of 7.4-8.4 in 12+log(O/H) and stellar masses 10^7.5-10^11 Msun. We test commonly used strong line diagnostics (R23, O3, O2, O32, N2, O3N2 and Ne3O2 ) as prescribed by four different sets of empirical calibrations, as well as one fully theoretical calibration. We find that none of the strong line diagnostics (or calibration set) tested perform consistently better than the others. Amongst the line ratios tested, R23 and O3 deliver the best results, with accuracies as good as 0.01-0.04 dex and dispersions of ~0.2 dex in two of the calibrations tested. Generally, line ratios involving nitrogen predict higher values of metallicity, while results with O32 and Ne3O2 show large dispersions. The theoretical calibration yields an accuracy of 0.06 dex, comparable to the best strong line methods. We conclude that, within the metallicity range tested in this work, the locally calibrated diagnostics can still be reliably applied at z~2.Comment: 12 pages, 8 Figures, accepted for publication in MNRA
    corecore