31 research outputs found

    Multi-vessel stenting during primary percutaneous coronary intervention for acute myocardial infarction. A single-center experience

    Get PDF
    BACKGROUND: Recanalization of the culprit lesion is the main goal of primary angioplasty for acute ST-segment elevation myocardial infarction (STEMI). Patients presenting with acute myocardial infarction and multivessel disease are, therefore, usually subjected to staged procedures, with the primary percutaneous coronary intervention (PCI) confined to recanalization of the infarct-related artery (IRA). Theoretically at least, early relief of stenoses of non-infarct-related arteries could promote collateral circulation, which could help to limit the infarct size. However, the safety and feasibility of such an approach has not been adequately established. METHODS: In this single-center prospective study we examined 73 consecutive patients who had an acute STEMI and at least one or more lesions > or = 70% in a major epicardial vessel other than the infarct-related artery. In the first 28 patients, forming the multi-vessel (MV) PCI group, all lesions were treated during the primary procedure. In the following 45 patients, forming the culprit-only (CO) PCI group, only the culprit lesion was treated during the initial procedure, followed by either planned-staged or ischemia-driven revascularization of the non-culprit lesions. Fluoroscopy time and contrast dye amount were compared between both groups, and patients were followed up for one year for major adverse cardiac events (MACE) and other significant clinical events. RESULTS: The two groups were well balanced in terms of clinical characteristics, number of diseased vessels and angiographic characteristics of the culprit lesion. In the MV-PCI group, 2.51 lesions per patient were treated using 2.96 +/- 1.34 stents (1.00 lesions and 1.76 +/- 1.17 stents in the CO-PCI group, both p < 0.001). The fluoroscopy time increased from 10.3 (7.2-16.9) min in the CO-PCI group to 12.5 (8.5-19.3) min in the MV-PCI group (p = 0.22), and the amount of contrast used from 200 (180-250) ml to 250 (200-300) ml, respectively (p = 0.16). Peak CK and CK-MB were significantly lower in patients of the MV-PCI group (843 +/- 845 and 135 +/- 125 vs 1652 +/- 1550 and 207 +/- 155 U/l, p < 0.001 and 0.01, respectively). Similar rates of major adverse cardiac events at one year were observed in the two groups (24% and 28% in multi-vessel and culprit treatment groups, p = 0.73). The incidence of new revascularization in both infarct- and non-infarct-related arteries was also similar (24% and 28%, respectively, p = 0.73). CONCLUSION: We may state from this limited experience that a multi-vessel stenting approach for patients with acute STEMI and multi-vessel disease is feasible and probably safe during routine clinical practice. Our data suggest that this approach may help to limit the infarct size. However, larger studies, perhaps using drug-eluting stents, are still needed to further evaluate the safety and efficiency of this procedure, and whether it is associated with a lower need of subsequent revascularization and lower costs

    Sustained safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial.

    Get PDF
    Metal absorbable scaffolds constitute a conceptually attractive alternative to polymeric scaffolds. Promising 6-month outcomes of a second-generation drug-eluting absorbable metal scaffold (DREAMS 2G), consisting of an absorbable magnesium scaffold backbone, have been reported. We assessed the 12-month safety and performance of this novel device. The prospective, international, multi-centre, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to two de novo lesions with a reference diameter between 2.2 and 3.7 mm. All patients were scheduled for angiographic follow-up at 6 months, and-if subjects consented-at 12 months. Dual antiplatelet therapy was recommended for 6 months. Quantitative coronary angiography (QCA) parameters remained stable from 6 to 12 months [paired data of 42 patients: in-segment late lumen loss 0.20 ± 0.21 mm vs. 0.25 ± 0.22 mm, P = 0.117, Δ 0.05 ± 0.21 mm (95% CI: -0.01;0.12); in-scaffold late lumen loss 0.37 ± 0.25 mm vs. 0.39 ± 0.27 mm, P = 0.446, Δ 0.03 ± 0.22 (95% CI: -0.04;0.10), respectively]. Intravascular ultrasound and optical coherence tomography findings corroborated the QCA results. Target lesion failure occurred in four patients (3.4%), consisting of one death of unknown cause, one target-vessel myocardial infarction, and two clinically driven target lesion revascularization. No additional event occurred beyond the 6-month follow-up. During the entire follow-up of 12 months, none of the patients experienced a definite or probable scaffold thrombosis. The novel drug-eluting metal absorbable scaffold DREAMS 2G showed a continuous favourable safety profile up to 12 months and stable angiographic parameters between 6 and 12 months. NCT01960504

    1-Year outcomes after transcatheter aortic valve replacement with balloon-expandable versus self-expandable valves

    Get PDF
    BACKGROUND The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable transcatheter heart valve. OBJECTIVES The aim of this study was to evaluate clinical and echocardiographic outcome data at longer term follow-up. METHODS The investigator-initiated trial randomized 241 high-risk patients with symptomatic severe aortic stenosis and anatomy suitable for treatment with both balloon- and self-expandable transcatheter heart valves to transfemoral transcatheter aortic valve replacement with either device. Patients were followed-up for 1 year, with assessment of clinical outcomes and echocardiographic evaluation of valve function. RESULTS At 1 year, the rates of death of any cause (17.4% vs. 12.8%; relative risk [RR]: 1.35; 95% confidence interval [CI]: 0.73 to 2.50; p ¼ 0.37) and of cardiovascular causes (12.4% vs. 9.4%; RR: 1.32; 95% CI: 0.63 to 2.75; p ¼ 0.54) were not statistically significantly different in the balloon- and self-expandable groups, respectively. The frequencies of all strokes (9.1% vs. 3.4%; RR: 2.66; 95% CI: 0.87 to 8.12; p ¼ 0.11) and repeat hospitalization for heart failure (7.4% vs. 12.8%; RR: 0.58; 95% CI: 0.26 to 1.27; p ¼ 0.19) did not statistically significantly differ between the 2 groups. Elevated transvalvular gradients during follow-up were observed in 4 patients in the balloon-expandable group (3.4% vs. 0%; p ¼ 0.12); all were resolved with anticoagulant therapy, suggesting a thrombotic etiology. More than mild paravalvular regurgitation was more frequent in the self-expandable group (1.1% vs. 12.1%; p ¼ 0.005). CONCLUSIONS Despite the higher device success rate with the balloon-expandable valve, 1-year follow-up of patients in CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT Trial), with limited statistical power, revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with both balloon- and self-expandable prostheses that were not statistically significantly different. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial; NCT01645202) (J Am Coll Cardiol 2015;66:791–800) © 2015 by the American College of Cardiology Foundation

    Elucidation of the liquid-liquid distribution behavior of ion associates of metal-halogeno complex anions with quaternary ammonium counter cations and its application to separation and analysis

    Get PDF
    第四級アンモニウムイオンを対イオンとする一価, 二価金属ハロゲノ錯陰イオンのイオン会合抽出挙動を把握し, 分離・分析的応用を図るために, 炭素数及び形状の異なる第四級アンモニウム陽イオンを用いて, 水-各種抽出溶媒 {1,2-ジクロロエタン, クロロホルム (CF), クロロベンゼン (Cl-B), ベンゼン (B), トルエン (T) 及び四塩化炭素 (CTC)} 系での抽出定数を求めた. 得られた抽出定数から次の知見を得た. (1) 配位子の抽出性に及ぼす影響 : 配位子がCl-, Br-, I-と変わるにつれ, この順に抽出性は良くなる. (2) 配位子数の影響 : 配位子数が多くなるに従い, 抽出性も良くなる. (3) 中心金属の影響 : 配位子数が同じ場合には, 抽出性はほぼ中心金属イオンの大きさの順となる. (4) 金属錯陰イオンの電荷の影響 : 一般に二価陰イオンよりも一価陰イオンのほうが抽出されやすい. (5) 対陽イオンのアルキル鎖のメチレン基の寄与 : メチレン基一つ当たり, 大体0.4~0.8の抽出定数 (log K(ex)) の増大となる. (6) 抽出溶媒の影響 : 抽出溶媒の抽出能は次の順となる : CTC<T<B<Cl-B<CF. (7) 金属ハロゲノ錯陰イオンの配位子の違いによる抽出定数の差 (Δlog K(ex)) は溶媒によらず, ほぼ一定である. これらの知見を基に, 金属ハロゲノ錯陰イオンと疎水性陽イオンとのイオン会合抽出を利用する幾つかの金属の分離・定量法を開発した.The distribution behavior of ion associates of both monovalent and divalent metal-halogeno complex anions with various quaternary ammonium cations between the aqueous phase and several organic phases {1,2-dichloroethane, chloroform (CF), chlorobenzene (Cl-B), benzene (B), toluene (T) and carbon tetrachloride (CTC)} was examined, and the extraction constants (log Kex) were determined. The larger is the size of the ligand (Cl-<Br-<I-) and the coordination number, the greater is the ion associability. For the same coordination number, in general, the larger is the size of the metal ion, the greater is the ion associability. In general, the extractability of monovalent metal-halogeno complex anions is larger than that of divalent metal-halogeno complex anions. A linear relationship was obtained between log Kex and the number of carbon atoms in quaternary ammonium ion, and the contribution of a methylene group to the extraction constant (Δlog K(ex)/-CH(2-)) was found to be about 0.4∼0.8. Among the ion associates examined, the order of the extractability of the extracting solvent was generally CTC<T<B<Cl-B<CF. Also, the order of the extractability of the ion associates for dihalogenocuprate (I), tetrahalogenoaurate (III) and tetrahalogenothallate (III) complex ions was as follows, respectively : CuCl(2)-<CuBr(2)-<CuI(2)- ; AuCl(4)-<AuBr(4)- ; TlCl(4)-<TlBr(4)-<TlI(4-). The values of Δlog K(ex) between the complex anions were almost equal, even though the extracting solvents were changed. From these results, several extraction-spectrophotometric methods for the determination of metal based on the formation of an ion associate of metal-halogeno complex anion with hydrophobic cations were developed

    Comparison of clinical outcomes between Magmaris and Orsiro drug eluting stent at 12 months: Pooled patient level analysis from BIOSOLVE II–III and BIOFLOW II trials

    Get PDF
    Background: The aim of this study was to compare the 12-month clinical outcomes of patients treated with Magmaris or Orsiro. Second generation drug-eluting absorbable metal scaffold Magmaris (Dreams 2G) has proved to be safe and effective in the BIOSOLVE-II study. Similarly, biodegradable polymer sirolimus-eluting stent, Orsiro has shown notable clinical results even in all-comer populations. Methods: Magmaris group patients were taken from the BIOSOLVE-II and BIOSOLVE-III trials, while the patients from Orsiro group were enrolled in BIOFLOW-II trial. The primary outcome was explored using a time-to-event assessment of the unadjusted clinical outcomes for target lesion failure (TLF) at 12 months, followed by a multivariate analysis adjusting for all the significantly different covariates between the groups. Results: The study population consisted of 482 patients (521 lesions), 184 patients (189 lesions) in Magmaris group and 298 patients (332 lesions) in Orsiro group. The mean age was 65.5 ± 10.8 and 62.7 ± 10.4 years in Magmaris and Orsiro groups, respectively (p = 0.005). Magmaris and Orsiro unadjusted TLF rates were 6.0 and 6.4% with no significant difference between the groups (p = 0.869). In the multivariate analysis, there were no meaningful differences between Magmaris and Orsiro groups. Finally, none of the groups presented device thrombosis cases at 12 months. Conclusion: At 12 months there were no significant differences between Magmaris and Orsiro groups neither in the unadjusted assessment nor in the multivariate analysis for target lesion failure. These results should be taken as hypothesis generating and may warrant a head to head comparison on a randomized fashion

    Response to A Haverich’s letter

    No full text

    Sustained Safety and Performance of the Second-Generation Sirolimus-Eluting Absorbable Metal Scaffold: Pooled Outcomes of the BIOSOLVE-II and -III Trials at 3 Years

    No full text
    Background/purpose: To avoid long-term effects associated with permanent implants, bioresorbable vascular scaffolds were developed, as they provide transient vessel support and disappear thereafter. The aim of the BIOSOLVE-II and -III studies was to assess the safety and performance of a magnesium-based sirolimus-eluting scaffold; we report the clinical outcomes at 3 years, 2 years after scaffold resorption. Methods/materials: BIOSOLVE-II and BIOSOLVE-III are international, prospective multi-center studies, including 184 patients with 189 de novo lesions and stable or unstable angina, or documented silent ischemia. Acute myocardial infarction, 3-vessel coronary artery disease, and heavily calcified lesions were excluded. Antiplatelet therapy was recommended for 6 months. Results: Patients were 65.5 ± 10.8 years old, and lesions were 12.1 ± 4.5 mm long and located in vessels with a diameter of 2.7 ± 0.4 mm. More than half of the lesions (56.5%) were type B2/C lesions. At 2 years, 92.5% (160/173) of patients were symptom-free and 91.5% (151/165) at 3 years; all the other patients had stable angina. At 3 years, target lesion failure occurred in 11 patients (6.3%), consisting of 4 cardiac deaths (2.3%), one target-vessel myocardial infarction (0.6%), and 6 clinically driven target lesion revascularizations (3.4%). There was no definite or probable scaffold thrombosis. Conclusion: In a low-risk patient population, treatment with a sirolimus-eluting magnesium bioresorbable scaffold can be considered safe, in particular with no definite or probable scaffold thrombosis. Annotated table of contents: BIOSOLVE-II and -III are prospective, international, multi-center studies including 184 patients with de novo lesions. At 3 years, target lesion failure was 6.3%, consisting of 4 cardiac deaths (2.3%), one target-vessel myocardial infarction (0.6%), and 6 clinically driven target lesion revascularizations (3.4%). There was no definite or probable scaffold thrombosis

    Sustained Safety and Performance of a Second-Generation Sirolimus-Eluting Absorbable Metal Scaffold: Long-Term Data of the BIOSOLVE-II First-in-Man Trial at 5 Years.

    No full text
    Permanent drug-eluting stents are associated with a steady increase in late complications attributed to persistent inflammation and poor vessel remodelling. Bioresorbable scaffolds have been developed to overcome such long-term limitations by providing temporary vessel support and disappearing thereafter. We aimed to assess the long-term outcomes of an absorbable metallic scaffold at 5 years. BIOSOLVE-II is an international, multi-centre, first-in-human study assessing the safety and performance of the sirolimus-eluting absorbable metal scaffold DREAMS 2G (commercial name Magmaris) in patients with a maximum of two de novo lesions. After 3 years, follow-up was extended to 5 years with the endpoints of target lesion failure and rate of definite or probable stent thrombosis. A total of 123 patients with 123 lesions were enrolled. Lesions were 12.6 ± 4.5 mm long and 2.7 ± 0.4 mm in diameter, 43.4% were class B2/C lesions, and calcification was moderate to severe in 10.6%. At 5 years, 5.4% of patients had stable angina and 94.6% had no symptoms or ischaemia. Target lesion failure rate was 8.0% [95% confidence interval:4.2;14.9], reflecting 2 cardiac deaths, 2 target-vessel myocardial infarctions, and 6 clinically driven target lesion revascularizations (TLRs). Only one target lesion failure occurred beyond 3 years: a target-vessel myocardial infarction with clinically driven TLR on post-procedure day 1157. One additional non-cardiac death beyond 3 years due to renal failure was reported on day 1777. No definite or probable scaffold thrombosis was observed. The Magmaris scaffold showed favourable long-term safety and clinical performance with low target lesion failure rates and absence of definite or probable scaffold thrombosis throughout 5 years
    corecore