72 research outputs found
Unscheduled return visits to a Dutch inner-city emergency department
© 2014, van der Linden et al.; licensee Springer. Background: Unscheduled return visits to the emergency department (ED) may reflect shortcomings in care. This study characterized ED return visits with respect to incidence, risk factors, reasons and post-ED disposition. We hypothesized that risk factors for unscheduled return and reasons for returning would differ from previous studies, due to differences in health care systems. Methods: All unscheduled return visits occurring within 1 week and related to the initial ED visit were selected. Multivariable logistic regression was conducted to determine independent factors associated with unscheduled return, using patient information available at the initial visit. Reasons for returning unscheduled were categorized into illness-, patient- or physician-related. Post-ED disposition was compared between patients with unscheduled return visits and the patients who did not return. Results: Five percent (n = 2,492) of total ED visits (n = 49,341) were unscheduled return visits. Patients with an urgent triage level, patients presenting during the night shift, with a wound or local infection, abdominal pain or urinary problems were more likely to return unscheduled. Reasons to revisit unscheduled were mostly illness-related (49%) or patient-related (41%). Admission rates for returning patients (16%) were the same as for the patients who did not return (17%). Conclusions: Apart from abdominal complaints, risk factors for unscheduled return differ from previous studies. Short-term follow-up at the outpatient clinic or general practitioner for patients with urgent triage levels and suffering from wounds or local infections, abdominal pain or urinary problem might prevent unscheduled return
Vaginal cuff dehiscence in laparoscopic hysterectomy: influence of various suturing methods of the vaginal vault
Vaginal cuff dehiscence (VCD) is a severe adverse event and occurs more frequently after total laparoscopic hysterectomy (TLH) compared with abdominal and vaginal hysterectomy. The aim of this study is to compare the incidence of VCD after various suturing methods to close the vaginal vault. We conducted a retrospective cohort study. Patients who underwent TLH between January 2004 and May 2011 were enrolled. We compared the incidence of VCD after closure with transvaginal interrupted sutures versus laparoscopic interrupted sutures versus a laparoscopic single-layer running suture. The latter was either bidirectional barbed or a running vicryl suture with clips placed at each end commonly used in transanal endoscopic microsurgery. Three hundred thirty-one TLHs were included. In 75 (22.7 %), the vaginal vault was closed by transvaginal approach; in 90 (27.2 %), by laparoscopic interrupted sutures; and in 166 (50.2 %), by a laparoscopic running suture. Eight VCDs occurred: one (1.3 %) after transvaginal interrupted closure, three (3.3 %) after laparoscopic interrupted suturing and four (2.4 %) after a laparoscopic running suture was used (p = .707). With regard to the incidence of VCD, based on our data, neither a superiority of single-layer laparoscopic closure of the vaginal cuff with an unknotted running suture nor of the transvaginal and the laparoscopic interrupted suturing techniques could be demonstrated. We hypothesise that besides the suturing technique, other causes, such as the type and amount of coagulation used for colpotomy, may play a role in the increased risk of VCD after TLH
Unscheduled return visits to a Dutch inner-city emergency department
Background Unscheduled return visits to the emergency department (ED) may reflect shortcomings in care. This study characterized ED return visits with respect to incidence, risk factors, reasons and post-ED disposition. We hypothesized that risk factors for unscheduled return and reasons for returning would differ from previous studies, due to differences in health care systems. Methods All unscheduled return visits occurring within 1 week and related to the initial ED visit were selected. Multivariable logistic regression was conducted to determine independent factors associated with unscheduled return, using patient information available at the initial visit. Reasons for returning unscheduled were categorized into illness-, patient- or physician-related. Post-ED disposition was compared between patients with unscheduled return visits and the patients who did not return. Results Five percent (n = 2,492) of total ED visits (n = 49,341) were unscheduled return visits. Patients with an urgent triage level, patients presenting during the night shift, with a wound or local infection, abdominal pain or urinary problems were more likely to return unscheduled. Reasons to revisit unscheduled were mostly illness-related (49%) or patient-related (41%). Admission rates for returning patients (16%) were the same as for the patients who did not return (17%). Conclusions Apart from abdominal complaints, risk factors for unscheduled return differ from previous studies. Short-term follow-up at the outpatient clinic or general practitioner for patients with urgent triage levels and suffering from wounds or local infections, abdominal pain or urinary problem might prevent unscheduled return
A hinged external fixator for complex elbow dislocations: A multicenter prospective cohort study
Background: Elbow dislocations can be classified as simple or complex. Simple dislocations are characterized by the absence of fractures, while complex dislocations are associated with fractures of the radial head, olecranon, or coronoid process. The majority of patients with these complex dislocations are treated with open reduction and internal fixation (ORIF), or arthroplasty in case of a non-reconstructable radial head fracture. If the elbow joint remains unstable after fracture fixation, a hinged elbow fixator can be applied. The fixator provides stability to the elbow joint, and allows for early mobilization. The latter may be important for preventing stiffness of the joint. The aim of this study is to determine the effect of early mobilization with a hinged external elbow fixator on clinical outcome in patients with complex elbow dislocations with residual instability following fracture fixation. Methods/Design. The design of the study will be a multicenter prospective cohort study of 30 patients who have sustained a complex elbow dislocation and are treated with a hinged elbow fixator following fracture fixation because of residual instability. Early active motion exercises within the limits of pain will be started immediately after surgery under supervision of a physical therapist. Outcome will be evaluated at regular intervals over the subsequent 12 months. The primary outcome is the Quick Disabilities of the Arm, Shoulder, and Hand score. The secondary outcome measures are the Mayo Elbow Performance Index, Oxford Elbow Score, pain level at both sides, range of motion of the elbow joint at both sides, radiographic healing of the fractures and formation of periarticular ossifications, rate of secondary interventions and complications, and health-related quality of life (Short-Form 36). Discussion. The outcome of this study will yield quantitative data on the functional outcome in patients with a complex elbow dislocation and who are treated with ORIF and additional stabilization with a hinged elbow fixator. Trial Registration. The trial is registered at the Netherlands Trial Register (NTR1996)
Differences in Characteristics and Outcome of Patients with Penetrating Injuries in the USA and the Netherlands: A Multi-institutional Comparison
Introduction: The incidence and nature of penetrating injuries differ between countries. The aim of this study was to analyze characteristics and clinical outcomes of patients with penetrating injuries treated at urban Level-1 trauma centers in the USA (USTC) and the Netherlands (NLTC). Methods: In this retrospective cohort study, 1331 adult patients (470 from five NLTC and 861 from three USTC) with truncal penetrating injuries admitted between July 2011 and December 2014 were included. In-hospital mortality was the primary outcome. Outcome comparisons were adjusted for differences in population characteristics in multivariable analyses. Results: In USTC, gunshot wound injuries (36.1 vs. 17.4%, p < 0.001) and assaults were more frequent (91.2 vs. 77.7%, p < 0.001). ISS was higher in USTC, but the Revised Trauma Score (RTS) was comparable. In-hospital mortality was similar (5.0 vs. 3.6% in NLTC, p = 0.25). The adjusted odds ratio for mortality in USTC compared to NLTC was 0.95 (95% confidence interval 0.35–2.54). Hospital stay length of stay was shorter in USTC (difference 0.17 days, 95% CI −0.29 to −0.05, p = 0.005), ICU admission rate was comparable (OR 0.96, 95% CI 0.71–1.31, p = 0.80), and ICU length of stay was longer in USTC (difference of 0.39 days, 95% CI 0.18–0.60, p < 0.0001). More USTC patients were discharged to home (86.9 vs. 80.6%, p < 0.001). Readmission rates were similar (5.6 vs. 3.8%, p = 0.17). Conclusion: Despite the higher incidence of penetrating trauma, particularly firearm-related injuries, and higher hospital volumes in the USTC compared to the NLTC, the in-hospital mortality was similar. In this study, outcome of care was not significantly influenced by differences in incidence of firearm-related injuries
Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures
Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo
- …