39 research outputs found

    Major bleeding during negative pressure wound/V.A.C.® - therapy for postsurgical deep sternal wound infection - a critical appraisal

    Get PDF
    Negative-pressure wound therapy, commercially known as vacuum-assisted closure (V.A.C.®) therapy, has become one of the most popular (and efficacious) interim (prior to flap reconstruction) or definite methods of managing deep sternal wound infection. Complications such as profuse bleeding, which may occur during negative-pressure therapy but not necessarily due to it, are often attributed to a single factor and reported as such. However, despite the wealth of clinical experience internationally available, information regarding certain simple considerations is still lacking. Garnering information on all the factors that could possibly influence the outcome has become more difficult due to a (fortunate) decrease in the incidence of deep sternal wound infection. If more insight is to be gained from fewer clinical cases, then various potentially confounding factors should be fully disclosed before complications can be attributed to the technique itself or improvements to negative-pressure wound therapy for deep sternal wound infection can be accepted as evidence-based and the guidelines for its use adapted. The authors propose the adoption of a simple checklist in such cases

    A preliminary study of the effect of closed incision management with negative pressure wound therapy over high-risk incisions

    Get PDF
    Background Certain postoperative wounds are recognised to be associated with more complications than others and may be termed high-risk. Wound healing can be particularly challenging following high-energy trauma where wound necrosis and infection rates are high. Surgical incision for joint arthrodesis can also be considered high-risk as it requires extensive and invasive surgery and postoperative distal limb swelling and wound dehiscence are common. Recent human literature has investigated the use of negative pressure wound therapy (NPWT) over high-risk closed surgical incisions and beneficial effects have been noted including decreased drainage, decreased dehiscence and decreased infection rates. In a randomised, controlled study twenty cases undergoing distal limb high-energy fracture stabilisation or arthrodesis were randomised to NPWT or control groups. All cases had a modified Robert-Jones dressing applied for 72 h postoperatively and NPWT was applied for 24 h in the NPWT group. Morphometric assessment of limb circumference was performed at six sites preoperatively, 24 and 72 h postoperatively. Wound discharge was assessed at 24 and 72 h. Postoperative analgesia protocol was standardised and a Glasgow Composite Measure Pain Score (GCPS) carried out at 24, 48 and 72 h. Complications were noted and differences between groups were assessed. Results Percentage change in limb circumference between preoperative and 24 and 72 h postoperative measurements was significantly less at all sites for the NPWT group with exception of the joint proximal to the surgical site and the centre of the operated bone at 72 h. Median discharge score was lower in the NPWT group than the control group at 24 h. No significant differences in GCPS or complication rates were noted. Conclusions Digital swelling and wound discharge were reduced when NPWT was employed for closed incision management. Larger studies are required to evaluate whether this will result in reduced discomfort and complication rates postoperatively

    A rigid barrier between the heart and sternum protects the heart and lungs against rupture during negative pressure wound therapy

    Get PDF
    <p>Abstract</p> <p>Objectives</p> <p>Right ventricular heart rupture is a devastating complication associated with negative pressure wound therapy (NPWT) in cardiac surgery. The use of a rigid barrier has been suggested to offer protection against this lethal complication, by preventing the heart from being drawn up and damaged by the sharp edges of the sternum. The aim of the present study was to investigate whether a rigid barrier protects the heart and lungs against injury during NPWT.</p> <p>Methods</p> <p>Sixteen pigs underwent median sternotomy followed by NPWT at -120 mmHg for 24 hours, in the absence (eight pigs) or presence (eight pigs) of a rigid plastic disc between the heart and the sternal edges. The macroscopic appearance of the heart and lungs was inspected after 12 and 24 hours of NPWT.</p> <p>Results</p> <p>After 24 hours of NPWT at -120 mmHg the area of epicardial petechial bleeding was 11.90 ± 1.10 cm<sup>2 </sup>when no protective disc was used, and 1.15 ± 0.19 cm<sup>2 </sup>when using the disc (p < 0.001). Heart rupture was observed in three of the eight animals treated with NPWT without the disc. Lung rupture was observed in two of the animals, and lung contusion and emphysema were seen in all animals treated with NPWT without the rigid disc. No injury to the heart or lungs was observed in the group of animals treated with NPWT using the rigid disc.</p> <p>Conclusion</p> <p>Inserting a rigid barrier between the heart and the sternum edges offers protection against heart rupture and lung injury during NPWT.</p

    Effects on heart pumping function when using foam and gauze for negative pressure wound therapy of sternotomy wounds

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Negative pressure wound therapy (NPWT) has remarkable effects on the healing of poststernotomy mediastinitis. Foam is presently the material of choice for NPWT in this indication. There is now increasing interest in using gauze, as this has proven successful in the treatment of peripheral wounds. It is important to determine the effects of NPWT using gauze on heart pumping function before it can be used for deep sternotomy wounds. The aim was to examine the effects of NPWT when using gauze and foam on the heart pumping function during the treatment of a sternotomy wound.</p> <p>Methods</p> <p>Eight pigs underwent median sternotomy followed by NPWT at -40, -70, -120 and -160 mmHg, using foam or gauze. The heart frequency, cardiac output, mean systemic arterial pressure, mean pulmonary artery pressure, central venous pressure and left atrial pressure were recorded.</p> <p>Results</p> <p>Cardiac output was not affected by NPWT using gauze or foam. Heart frequency decreased during NPWT when using foam, but not gauze. Treatment with foam also lowered the central venous pressure and the left atrial pressure, while gauze had no such effects. Mean systemic arterial pressure, mean pulmonary artery pressure and systemic vascular resistance were not affected by NPWT. Similar haemodynamic effects were observed at all levels of negative pressure studied.</p> <p>Conclusions</p> <p>NPWT using foam results in decreased heart frequency and lower right and left atrial filling pressures. The use of gauze in NPWT did not affect the haemodynamic parameters studied. Gauze may thus provide an alternative to foam for NPWT of sternotomy wounds.</p

    Risk analysis and outcome of mediastinal wound and deep mediastinal wound infections with specific emphasis to omental transposition

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To report our experience, with Deep mediastinal wound infections (DMWI). Emphasis was given to the management of deep infections with omental flaps</p> <p>Methods</p> <p>From February 2000 to October 2007, out of 3896 cardiac surgery patients (prospective data collection) 120 pts (3.02%) developed sternal wound infections. There were 104 males & 16 females; (73.7%) CABG, (13.5%) Valves & (9.32%) CABG and Valve.</p> <p>Results</p> <p>Superficial sternal wound infection detected in 68 patients (1.75%) and fifty-two patients (1.34%) developed DMWI. The incremental risk factors for development of DMWI were: Diabetes (OR = 3.62, CI = 1.2-10.98), Pre Op Creatinine > 200 μmol/l (OR = 3.33, CI = 1.14-9.7) and Prolong ventilation (OR = 4.16, CI = 1.73-9.98). Overall mortality for the DMWI was 9.3% and the specific mortality of the omental flap group was 8.3%. 19% of the "DMWI group", developed complications: hematoma 6%, partial flap loss 3.0%, wound dehiscence 5.3%. Mean Hospital Stay: 59 ± 21.5 days.</p> <p>Conclusion</p> <p>Post cardiac surgery sternal wound complications remain challenging. The role of multidisciplinary approach is fundamental, as is the importance of an aggressive early wound exploration especially for deep sternal infections.</p

    Microvascular blood flow response in the intestinal wall and the omentum during negative wound pressure therapy of the open abdomen

    Get PDF
    PURPOSE: Higher closure rates of the open abdomen have been reported with negative pressure wound therapy (NPWT) compared with other wound therapy techniques. However, the method has occasionally been associated with increased development of intestinal fistulae. The present study measures microvascular blood flow in the intestinal wall and the omentum before and during NPWT. METHODS: Six pigs underwent midline incision and application of NPWT to the open abdomen. The microvascular blood flow in the underlying intestinal loop wall and the omentum was recorded before and after the application of NPWT of -50, -70, -100, -120, -150, and -170 mmHg respectively, using laser Doppler velocimetry. RESULTS: A significant decrease in microvascular blood flow was seen in the intestinal wall during application of all negative pressures levels. The blood flow was 2.7 (±0.2) Perfusion Units (PU) before and 2.0 (±0.2) PU (*p < 0.05) after application of -50 mmHg, and 3.6 (±0.6) PU before and 1.5 (±0.2) PU (**p < 0.01) after application of -170 mmHg. CONCLUSIONS: In the present study, we show that negative pressures between -50 and -170 mmHg induce a significant decrease in the microvascular blood flow in the intestinal wall. The decrease in blood flow increased with the amount of negative pressure applied. One can only speculate that a longstanding decreased blood flow in the intestinal wall may induce ischemia and secondary necrosis in the intestinal wall, which, theoretically, could promote the development of intestinal fistulae. We believe that NPWT of the open abdomen is a very effective treatment but could probably be improved

    Wound contraction and macro-deformation during negative pressure therapy of sternotomy wounds

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Negative pressure wound therapy (NPWT) is believed to initiate granulation tissue formation via macro-deformation of the wound edge. However, only few studies have been performed to evaluate this hypothesis. The present study was performed to investigate the effects of NPWT on wound contraction and wound edge tissue deformation.</p> <p>Methods</p> <p>Six pigs underwent median sternotomy followed by magnetic resonance imaging in the transverse plane through the thorax and sternotomy wound during NPWT at 0, -75, -125 and -175 mmHg. The lateral width of the wound and anterior-posterior thickness of the wound edge was measured in the images.</p> <p>Results</p> <p>The sternotomy wound decreased in size following NPWT. The lateral width of the wound, at the level of the sternum bone, decreased from 39 ± 7 mm to 30 ± 6 mm at -125 mmHg (p = 0.0027). The greatest decrease in wound width occurred when switching from 0 to -75 mmHg. The level of negative pressure did not affect wound contraction (sternum bone: 32 ± 6 mm at -75 mmHg and 29 ± 6 mm at -175 mmHg, p = 0.0897). The decrease in lateral wound width during NPWT was greater in subcutaneous tissue (14 ± 2 mm) than in sternum bone (9 ± 2 mm), resulting in a ratio of 1.7 ± 0.3 (p = 0.0423), suggesting macro-deformation of the tissue. The anterior-posterior thicknesses of the soft tissue, at 0.5 and 2.5 cm laterally from the wound edge, were not affected by negative pressure.</p> <p>Conclusions</p> <p>NPWT contracts the wound and causes macro-deformation of the wound edge tissue. This shearing force in the tissue and at the wound-foam interface may be one of the mechanisms by which negative pressure delivery promotes granulation tissue formation and wound healing.</p

    Design and validation of Segment - freely available software for cardiovascular image analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Commercially available software for cardiovascular image analysis often has limited functionality and frequently lacks the careful validation that is required for clinical studies. We have already implemented a cardiovascular image analysis software package and released it as freeware for the research community. However, it was distributed as a stand-alone application and other researchers could not extend it by writing their own custom image analysis algorithms. We believe that the work required to make a clinically applicable prototype can be reduced by making the software extensible, so that researchers can develop their own modules or improvements. Such an initiative might then serve as a bridge between image analysis research and cardiovascular research. The aim of this article is therefore to present the design and validation of a cardiovascular image analysis software package (Segment) and to announce its release in a source code format.</p> <p>Results</p> <p>Segment can be used for image analysis in magnetic resonance imaging (MRI), computed tomography (CT), single photon emission computed tomography (SPECT) and positron emission tomography (PET). Some of its main features include loading of DICOM images from all major scanner vendors, simultaneous display of multiple image stacks and plane intersections, automated segmentation of the left ventricle, quantification of MRI flow, tools for manual and general object segmentation, quantitative regional wall motion analysis, myocardial viability analysis and image fusion tools. Here we present an overview of the validation results and validation procedures for the functionality of the software. We describe a technique to ensure continued accuracy and validity of the software by implementing and using a test script that tests the functionality of the software and validates the output. The software has been made freely available for research purposes in a source code format on the project home page <url>http://segment.heiberg.se</url>.</p> <p>Conclusions</p> <p>Segment is a well-validated comprehensive software package for cardiovascular image analysis. It is freely available for research purposes provided that relevant original research publications related to the software are cited.</p
    corecore