1,563 research outputs found
Railroads and Local Economic Development: The United States in the 1850s
We use county and individual-level data from 1850 and 1860 to examine the economic impact of gaining access to a railroad. Previous studies have found that rail access was positively correlated with the value of agricultural land at a point in time, and have interpreted this correlation as evidence that rail access chiefly benefitted agricultural land owners in the manner predicted by the Hekscher-Ohlin or Von Theunen models. We use a difference-in-difference strategy, comparing changes in outcomes in counties that gained rail access in the 1850s to those that either gained access earlier or did not have access before the Civil War. Most of the estimated effects are small and the signs are not wholly consistent with either model, under the null hypothesis that agriculture was the chief beneficiary of rail access. For example, we find that rail access appears to have increased urbanization, raised the likelihood of participation in the service sector, decreased agricultural yields, and reduced the share of improved acreage in total land area, opposite to the patterns predicted by either the Heckscher-Ohlin or Von Theunen models.
Optimasi TIME Dial Setting (TDS) Relay Arus Lebih Menggunakan Adaptive Modified Firefly Algorithm pada Sistem Kelistrikan PT. Pupuk Kalimantan Timur
Penggunaan relay arus lebih (over current relay) pada industri memerlukan pengaturan beberapa parameter seperti arus pickup (Ip), time dial setting (TDS), serta waktu operasi (top). Dalam standard acuan dicantumkan batasan-batasan dan formulasi dalam menentukan parameter tersebut. Salah satu permasalahan adalah penentuan TDS pada relay inverse (Kode ANSI 51). Umumnya penentuan nilai TDS dilakukan dengan metode trial and error, hal ini dirasa kurang efektif sehingga diusulkan suatu metode baru dalam menentukan TDS pada sistem kelistrikan eksisting PT. Pupuk Kalimantan Timur. Digunakan algoritma adaptive firefly yang dimodifikasi dalam menyelesaikan permasalahan dengan mempertimbangkan kurva starting motor dan perbedaan tipe kurva antar rela
Koordinasi Proteksi Adaptif Rele Arus Lebih Digital Menggunakan Metoda Artificial Neural Network Pada Sistem Mesh Dengan Pembangkit Tersebar
Pada sistem mesh yang terkoneksi dengan pembangkit tersebar (Distributed Generation), terdapat kondisi dimana topologi jaringan yang berubah-ubah. Hal tersebut disebabkan oleh waktu operasi dari pembangkit tersebar yang bersifat temporary dan random. Kondisi ini dapat dibedakan yaitu terhubung dengan grid, terhubung grid dan DG1, terhubung grid dan DG2, dan terhubung grid dengan DG1 dan DG2. Akibat topologi jaringan yang berubah-ubah, menyebabkan peningkatan dan penurunan level arus hubung singkat sehingga seting dan koordinasi proteksi awal menjadi tidak efektif dan efisien lagi terhadap konfigurasi jaringan yang ada. Oleh karena itu dibutuhkan sistem proteksi yang setingnya dapat menyesuaikan dengan topologi jaringan yang berubah-ubah. Pada tugas akhir ini akan dirancang koordinasi sistem proteksi rele arah arus lebih yang dapat mengikuti setiap Perubahan kondisi pada topologi jaringan tersebut menggunakan metoda Artificial Neural Network dengan desain plant berbentuk mesh yang terhubung dengan Grid dan DG. Hasil perancangan menunjukan bahwa penggunaan metoda Artificial Neural Network dapat menghasilkan setingan rele yang adaptif mengikuti Perubahan topologi sistem. Dan metoda artificial neural network juga dapat memprediksi setingan rele pada saat terjadi gangguan yang diluar kondisi yang telah dipelajari dalam data learning
Molecular theory of elastic constants of liquid crystals. III. Application to smectic phases with tilted orientational order
Using the density functional formalism we derive expression for the
distortion free energy for systems with continuous broken symmetry and use it
to derive expression for the elastic constants of smectic phases in which
director is tilted with respect to the smectic layer normal. As in the previous
papers of the series (Phys. Rev. A {\bf 45}, 974 (1992), E {\bf 49}, 501,
(1994)) the expressions for the elastic constants are written in terms of order
and structural parameters. The structural parameters involve the generalised
spherical harmonic coefficients of the direct pair correlation function of an
effective isotropic liquid. The density of this effective isotropic liquid
depends on the nature and amount of ordering present in the system and is
evaluated self- consistently. We estimate the value of elastic constants using
reasonable guess for the order and structural- parameters.Comment: 31 pages; 1 Fig. in GIF format, To be appear in Phys. Rev.
Analisa Pengaruh Koordinasi Peralatan Proteksi Terhadap Karakteristik Voltage Sag Di PT. Pupuk Kaltim (PKT) Bontang
Program paket merupakan software simulasi transien pada sistem tenaga yang digunakan untuk menganalisa pengujian jaringan listrik di industri pada kondisi saat gangguan. Untuk meneliti karakteristik voltage sag pada sistem jaringan listrik di industri dalam kondisi saat gangguan, digunakan dua metode untuk koordinasi peralatan proteksi. Keluaran dari hasil simulasi berupa kurva transien tegangan terhadap durasi waktu gangguan yang merupakan karakteristik voltage sag. Kurva hasil simulasi ini dievaluasi dengan kurva standar CBEMA, ITIC, dan SEMI yang telah distandarkan untuk performa jaringan. Hasil simulasi hubung singkat 3 fasa di titik Fault 2 menyebabkan tegangan sisa sebesar 88,4 % di tiap fasa, hubung singkat 1 fasa ke tanah sebesar 81,4 % di fasa A, 98,6 % di fasa B, dan 96,2 % di fasa C, hubung singkat antar fasa sebesar 92,6 % di fasa A, 105,9 % di fasa B, 87,6 % di fasa C. Metode kedua yaitu dengan CB atau pemutus dari hasil evaluasi simulasi didapatkan durasi gangguan yang lebih kecil dari metode pertama yaitu tanpa peralatan proteksi
Studi Perencanaan Filter Hybrid untuk Mengurangi Harmonisa pada Proyek Pakistan Deep Water Container Port
Pakistan Deep Water Container Port merupakan proyek pembangunan pelabuhan peti kemas yang berada di Karachi, Pakistan. Sebagai salah satu pelabuhan terbesar, Pakistan Deep Water Container Port harus memiliki target dalam jumlah proses bongkar-muat kapal-kapal kargo, baik dalam skala lokal maupun Internasional per-harinya. Oleh karena itu diperlukan motor-motor untuk melakukan hal tersebut. Salah satu cara untuk mengoperasikan motor agar dapat bekerja maksimal dan efisien adalah dengan mengatur kecepatan putar motor menggunakan VFD (Variable Frequency Drive). Namun, dalam penggunaan VFD terdapat komponen non linier, hal ini dapat menimbulkan masalah harmonisa, dimana frekuensi yang dihasilkan akan berpengaruh terhadap kualitas daya pada sistem kelistrikan yang ada serta dapat menimbulkan kerusakan pada peralatan, seperti: trafo dan kabel. Untuk mencegah hal tersebut perlu dilakukan studi perencanaan pemasangan filter untuk meredam frekuensi harmonisa yang timbul. Pada tugas akhir ini akan dirancang sebuah filter hybrid untuk mengurangi harmonisa yang timbul akibat adanya beban motor yang terpasang pada Pakistan Deep Water Container Port. Disini juga dilakukan studi berbagai kasus untuk mendapatkan hasil terbaik termasuk dalam penempatan filter pasif dan aktif, sehingga diperoleh keadaan yang maksimal dalam meredam harmonisa. Untuk pemodelan filter aktif dilakukan pada software Powersim sedangkan filter pasif dan filter hybrid dilakukan pada software ETAP 11.0.0
Rancang Bangun Perangkat Lunak Untuk Perhitungan Besar Arus Hubung Singkat Pada Sistem Distribusi Listrik Di Kapal
Salah satu penunjang untuk pengamanan jaringan listrik kapal adalah mengetahui berapa besar arus hubung singkat pada bus-bus tertentu di jaringan listrik kapal. Selama ini PT.PAL dalam hal menghitung hubung arus hubung singkat dilakukan secara manual. Untuk lebih meningkatkan efektifitas dan effisiensi kerja, maka pada penelitian ini penulis akan membuat program komputer untuk menghitung besar arus hubung singkat pada sistem distribusi listrik di kapal. Untuk ini penulis akan merancang suatu program yang terkenal dengan istilah user friendly yaitu dengan menggunakan program yang dapat menggambarkan diagram satu garis system tenaga listrik. Program ini mendukung interaksi langsung antara pemakai dan diagram satu garis Metoda yang dipakai dalam perhitungan ini adalah metoda matrik impedansi Z-bus. Dengan mengetahui besar arus hubung singkat 3 fasa maka dapat ditentukan besar breaking capacity dari peralatan pengaman. Manfaat lain yang dapat diperoleh adalah untuk menentukan setting pengaman
- …
