97 research outputs found

    Повышение конкурентноспособности продукции на основе эффективной системы управления качеством в организации

    Get PDF
    В процессе исследования проводились анализ и оценка конкурентоспособности предприятия и продукции и разработка мероприятий по повышению её конкурентоспособности.In the course of the research, the analysis and assessment of the competitiveness of the enterprise and products and the development of measures to increase its competitiveness were carried out

    Variables affecting the probability of complete fusion of the medial clavicular epiphysis

    Get PDF
    In this study, we have combined data on clavicle fusion from different studies and applied a binomial logistic regression analysis. As such, we aimed to assess whether or not variables such as sex, socioeconomic status, and ethnicity influence the probability of having mature, i.e., completely fused clavicles at a given age. We further explored whether the method of clavicle examination, i.e., diagnosis from either a dry bone specimen, an examination of X-rays, or an examination of computed tomography scans, affects the probability of being diagnosed with mature clavicles. It appeared that only ethnicity did not significantly affect this probability. Finally, we illustrated how the logit model may be used to predict the probability of being diagnosed with mature clavicles

    Система анализа геологических карт с помощью инструментов компьютерного зрения и машинного обучения

    Get PDF
    Несколько областей компьютерного зрения было исследовано в данной работе для того, чтобы разработать два модуля системы анализа структурных геологических карт – модуль анализа изображений и модуль исправления результатов анализа. Ряд различных современных методов машинного и глубокого обучения был применен на практике. Все подходы были оценены на синтетической выборке. На тестовой выборке были рассчитаны метрики mAP, IOU, F1 score.Several areas of computer vision were researched in order to develop two modules of a structural maps analysis system – image analysis and results correction modules. Multiple modern machine learning and deep learning methods were applied in this master’s thesis, such as. Different approaches were tested in the development process. All of them were validated on synthetic data. Three evaluation metrics (mAP, IOU, F1 score) were calculated during validation

    Die Follow-up-Empfehlungen der AG-ERA: Standardisierung und Qualitätssicherung

    No full text

    Recording of auditory steady-state evoked responses (ASSR) in real-time using a lock-in amplifier

    No full text
    Human auditory steady-state responses (ASSRs) are represented in the Electroencephalogram (EEG) by single spectral lines at the stimulus repetition rate. To increase the small signal-to noise ratio of these responses, commercial ASSR systems usually average several segments of the EEG signal prior to be converted from the time domain into the frequency domain. The averaging process however does not allow for a recording of ASSR in real time. This paper describes an experimental setup which replaces averaging and frequency analysis by a lock-in amplifier. Lock-in amplifiers are widely used in experimental physics to extract small signals of known frequency from an extremely noisy background. A lock-in amplifier multiplies the (noisy) input signal by a reference signal. Subsequent integration with a time constant of a few seconds results in a DC signal. In our setup, with a reference signal at the same frequency as the stimulus repetition rate, the DC output is proportional to the ASSR amplitude.Auditory steady-state responses were evoked in one normal hearing female adult by presenting wide-band chirp stimuli at 40 Hz repetition rate and 50 dB nHL presentation level through an insert earphone. The amplified and band pass filtered EEG signal was fed to the input channel of a Stanford Research Type 830 lock-in amplifier. A reference signal phase locked to the stimulus was fed to the amplifiers reference input. The DC output was maximized by manually shifting the phase of the reference signal. A Digital Multimeter (Keysight DMM34460A) and a Data Acquisition Application (Keysight BenchVue) were used to record the time course of the DC output proportional to the ASSR amplitude. Switching the acoustical stimulus on and off periodically, the DC output follows the response amplitude in real time. Typical examples for time constants of 1 s and 3 s are presented.This paper presents a feasibility analysis of a recording setup for auditory steady-state responses using a lock-in amplifier. The proposed method could be of some interest for intraoperative monitoring of the auditory nerve during implantation of middle ear protheses, neurosurgical procedures, and for brain-computer interfaces (BCI).Stationäre Potenziale des auditorischen Systems (ASSR) findet man bei periodischer Stimulation des Hörsystems im EEG-Spektrum als Spektrallinien mit exakt der Reizrate. Benutzt man zur Trennung von Signal und Störung die für transiente Potenziale übliche Mittelung reizsynchroner EEG-Abschnitte, wird die besondere Eigenschaft der stationären Potenziale, die exakte Kenntnis ihrer Frequenz, nicht beachtet. Ein Monitoring der ASSR in Echtzeit ist bei Anwendung des Mittelungsverfahrens nur eingeschränkt möglich. Diese Arbeit greift eine Idee von Schacham et al. auf und beschreibt einen experimentellen Aufbau, der es erlaubt, stationäre Potenziale des auditorischen Systems mit Hilfe eines kommerziellen Lock-in Verstärkers (Stanford Research 830) in Echtzeit darzustellen. In einem Lock-in Verstärker wird das verrauschte Nutzsignal mit einem Referenzsignal mit der Frequenz des Nutzsignals multipliziert. Ein Tiefpass eliminiert alle nicht zur Nutzfrequenz synchronen Rauschanteile, so dass am Ausgang des Lock-in Verstärkers eine dem Nutzsignal proportionale Gleichspannung anliegt. Das hier erstmals vorgestellte Messprinzip eignet sich für die Darstellung stationärer evozierte Potenziale bekannter Frequenz besonders gut. Für Chirpreize mit 40 pps und 50 dB nHL Reizpegel wurden an einer erwachsenen normalhörenden Probandin erfolgreich Amplituden-Zeit-Verläufe mit Zeitkonstanten von wenigen Sekunden registriert

    Objektive Diagnostik in der Pädaudiologie

    No full text
    Die Follow-up-Empfehlungen der Arbeitsgruppe ERA der ADANO beschreiben das aktuelle Methodeninventar der objektiven Diagnostik in der Pädaudiologie. Der Vortrag diskutiert dieses Methodeninventar im Kontext neuer Messverfahren und geht dabei besonders auf neue Reizmuster zur Auslösung von Hirnstammpotentialen (Chirps), neue Verfahren des Signalnachweises (ASSR) sowie auf Verfahren zur Qualitätssicherung (Reststörung) ein.Die Kompensation der frequenzabhängigen Laufzeit von Kurztonreizen auf der Basilarmembran durch das Chirp-Konzept hat mit der Implementierung des CE-Chirps in verschiedenen ERA-Systemen eine Stufe erreicht, die eine Nutzung dieses Reizes für frequenzspezifische Hörschwellenmessungen in der klinischen Routinediagnostik ermöglicht. Die Kombination bandbegrenzter CE-Chirps mit einem objektiven Signalnachweis im Frequenzbereich (ASSR) führt zu einem sehr effektiven und flexiblen Verfahren der frequenzspezifischen Hörschwellenmessungen bei Säuglingen und Kleinkindern. Darüber hinaus erlauben objektive Qualitätsmaße in modernen ERA-Systemen zum ersten Mal eine von subjektiven Entscheidungen unabhängige objektive Diagnostik in der Pädaudiologie

    Stationäre evozierte Potentiale des auditorischen Systems

    No full text
    corecore