59,018 research outputs found
The combined effects of salivas and occlusal indicators on occlusal contact forces
Background
Some occlusal detection products are designed for use on dry teeth, but this is not always achieved. Others are suited for dry and wet applications.
Objective
The objective of this study is to assess the combined effects, on occlusal contact forces, of two previously studied affecting variablesâocclusal detection products and saliva.
Methods
We used a fullâarch dentiform with three occlusal detection products (an articulating film, an articulation paper and TâScan) in combination with human (HS) and an artificial saliva. The maxillary arch assembly, weighing ~54 N (the maximum bite force), was lowered onto (occlusion) and lifted off (disclusion) of the mandibular arch through 10 cycles by a mechanical testing machine. The forces and moments acting on the mandibular arch were continuously recorded by a load cell that supported it.
Results
The maximum values of Flateral (the inâocclusal plane component of the occlusal contact force) were analysed by occlusion/disclusion separately using oneâway ANOVA, with factor for group type to identify the significant effect of salivas on products, effect of products, effect of salivas with products, effect of human saliva. A difference in occlusion and/or in disclusion was considered different. Statistical differences (P < 0.0001) in Flateral were found in: dry product vs product + HS, dry product vs product + artificial saliva (with articulating film and TâScan) and HS vs product + HS (with articulation paper and TâScan).
Conclusion
All products were affected by the salivas, except articulation paper by artificial saliva
- âŠ