9 research outputs found

    Modular Microsystem for the Isolation, Enumeration, and Phenotyping of Circulating Tumor Cells in Patients with Pancreatic Cancer

    Get PDF
    In this manuscript, we discuss the development and clinical use of a thermoplastic modular microsystem for the high-throughput analysis of CTCs directly from whole blood. The modular system offers some innovative features that address challenges currently associated with many CTC platforms; it can exhaustively process 7.5 ml of blood in less than 45 min with recoveries >90%. In addition, the system automates the post-selection CTC processing steps and thus, significantly reduces assay turnaround time (from selection to enumeration 8 h for many reported CTC platforms). The system is comprised of 3 functional modules including; (i) a thermoplastic CTC selection module composed of high aspect ratio (30 μm × 150 μm) channels containing anti-EpCAM antibodies that is scalable in terms of throughput by employing channel numbers ranging from 50 to 320 – the channel number is user selected to accommodate the volume of blood that must be processed; (ii) an impedance sensor module for label-less CTC counting; and (iii) a staining and imaging module for the placement of released cells into a 2D array within a common imaging plane for phenotypic identification. To demonstrate the utility of this system, blood samples from patients with local resectable and metastatic pancreatic ductal adenocarcinoma (PDAC) were analyzed. We demonstrate the ability to select EpCAM positive CTCs from PDAC patients in high purity (>86%) and with excellent yields (mean = 53 CTCs per ml for metastatic PDAC patients) using our modular system. In addition, we demonstrate the ability to detect CTCs in PDAC patients with local resectable disease (mean = 11 CTCs per ml)

    Discrete microfluidics for the isolation of circulating tumor cell subpopulations targeting fibroblast activation protein alpha and epithelial cell adhesion molecule

    Get PDF
    Circulating tumor cells consist of phenotypically distinct subpopulations that originate from the tumor microenvironment. We report a circulating tumor cell dual selection assay that uses discrete microfluidics to select circulating tumor cell subpopulations from a single blood sample; circulating tumor cells expressing the established marker epithelial cell adhesion molecule and a new marker, fibroblast activation protein alpha, were evaluated. Both circulating tumor cell subpopulations were detected in metastatic ovarian, colorectal, prostate, breast, and pancreatic cancer patients and 90% of the isolated circulating tumor cells did not co-express both antigens. Clinical sensitivities of 100% showed substantial improvement compared to epithelial cell adhesion molecule selection alone. Owing to high purity (>80%) of the selected circulating tumor cells, molecular analysis of both circulating tumor cell subpopulations was carried out in bulk, including next generation sequencing, mutation analysis, and gene expression. Results suggested fibroblast activation protein alpha and epithelial cell adhesion molecule circulating tumor cells are distinct subpopulations and the use of these in concert can provide information needed to navigate through cancer disease management challenges

    Modular Microsystem for the Isolation, Enumeration, and Phenotyping of Circulating Tumor Cells in Patients with Pancreatic Cancer

    No full text
    In this manuscript, we discuss the development and clinical use of a thermoplastic modular microsystem for the high-throughput analysis of CTCs directly from whole blood. The modular system offers some innovative features that address challenges currently associated with many CTC platforms; it can exhaustively process 7.5 mL of blood in less than 45 min with recoveries >90%. In addition, the system automates the postselection CTC processing steps and thus, significantly reduces assay turnaround time (from selection to enumeration <1.5 h as compared to >8 h for many reported CTC platforms). The system is composed of 3 functional modules including (i) a thermoplastic CTC selection module composed of high aspect ratio (30 μm × 150 μm) channels containing anti-EpCAM antibodies that is scalable in terms of throughput by employing channel numbers ranging from 50 to 320; the channel number is user selected to accommodate the volume of blood that must be processed; (ii) an impedance sensor module for label-less CTC counting; and (iii) a staining and imaging module for the placement of released cells into a 2D array within a common imaging plane for phenotypic identification. To demonstrate the utility of this system, blood samples from patients with local resectable and metastatic pancreatic ductal adenocarcinoma (PDAC) were analyzed. We demonstrate the ability to select EpCAM positive CTCs from PDAC patients in high purity (>86%) and with excellent yields (mean = 53 CTCs per mL for metastatic PDAC patients) using our modular system. In addition, we demonstrate the ability to detect CTCs in PDAC patients with local resectable disease (mean = 11 CTCs per mL)

    Value of Intraoperative Neck Margin Analysis During Whipple for Pancreatic Adenocarcinoma

    No full text
    During pancreaticoduodenectomy (PD) for ductal adenocarcinoma, a frozen section (FS) neck margin is typically assessed, and if positive, additional pancreas is removed to achieve an R0 margin. We analyzed the association of this practice with improved overall survival (OS). Patients who underwent PD for pancreatic ductal adenocarcinoma from January 2000 to August 2012 at 8 academic centers were classified by neck margin status as negative (R0) or microscopically positive (R1) on the basis of FS and permanent section (PS). Impact on OS of converting an FS-R1-neck margin to a PS-R0-neck margin by additional resection was assessed. A total of 1399 patients had FS neck margins analyzed. Median OS was 19.7 months. On FS, 152 patients (10.9%) were R1, and an additional 51 patients (3.6%) had false-negative FS-R0 margins. PS-R0-neck was achieved in 1196 patients (85.5%), 131 patients (9.3%) remained PS-R1, and 72 patients (5.1%) were converted from FS-R1-to-PS-R0 by additional resection. Median OS for PS-R0-neck patients was 21.1 months versus 13.7 months for PS-R1-neck patients (P < 0.001) and 11.9 months for FS-R1-to-PS-R0 patients (P < 0.001). Both FS-R1-to-PS-R0 and PS-R1-neck patients had larger tumors (P = 0.001), more perineural invasion (P = 0.02), and more node positivity (P = 0.08) than PS-R0-neck patients. On multivariate analysis controlling for adverse pathologic factors, FS-R1-to-PS-R0 conversion remained associated with significantly worse OS compared with PS-R0-neck patients (hazard ratio: 1.55; P = 0.009). For patients who undergo pancreaticoduodenectomy for pancreatic ductal adenocarcinoma, additional resection to achieve a negative neck margin after positive frozen section is not associated with improved OS

    Modular microsystem for the isolation, enumeration, and phenotyping of circulating tumor cells in patients with pancreatic cancer

    Get PDF
    In this manuscript, we discuss the development and clinical use of a thermoplastic modular microsystem for the high-throughput analysis of CTCs directly from whole blood. The modular system offers some innovative features that address challenges currently associated with many CTC platforms; it can exhaustively process 7.5 mL of blood in less than 45 min with recoveries >90%. In addition, the system automates the postselection CTC processing steps and thus, significantly reduces assay turnaround time (from selection to enumeration 8 h for many reported CTC platforms). The system is composed of 3 functional modules including (i) a thermoplastic CTC selection module composed of high aspect ratio (30 ??m ?? 150 ??m) channels containing anti-EpCAM antibodies that is scalable in terms of throughput by employing channel numbers ranging from 50 to 320; the channel number is user selected to accommodate the volume of blood that must be processed; (ii) an impedance sensor module for label-less CTC counting; and (iii) a staining and imaging module for the placement of released cells into a 2D array within a common imaging plane for phenotypic identification. To demonstrate the utility of this system, blood samples from patients with local resectable and metastatic pancreatic ductal adenocarcinoma (PDAC) were analyzed. We demonstrate the ability to select EpCAM positive CTCs from PDAC patients in high purity (>86%) and with excellent yields (mean = 53 CTCs per mL for metastatic PDAC patients) using our modular system. In addition, we demonstrate the ability to detect CTCs in PDAC patients with local resectable disease (mean = 11 CTCs per mL).close13
    corecore