225 research outputs found

    Optical Underwater Communication: The Potential of Using Converted Green LEDs in Coastal Waters

    Get PDF
    Compared to the open ocean where blue light-emitting diodes (LEDs) perform well for data communications, in coastal and harbor environments optical transmission becomes worse and the color of lowest attenuation shifts to green. Another problem concerns the “green–yellow gap” of LEDs, as the quantum efficiency of current commercially available green LEDs is poor. Since energy consumption is an important factor, particularly for battery-powered systems, using blue LEDs is a tradeoff. Recently, phosphor-converted green LEDs, which are pumped by highly efficient blue LEDs, have been introduced to the market, and this type of LED promises better performance. This paper compares the use of blue, green, and converted green LEDs for applications in optical underwater communication systems in coastal waters. Theoretical aspects of the overall LED-water-detector channel are presented. A method for determining individual system coefficients is developed, and the impact on the communication system performance is explained. Practical approaches are introduced, complemented by measurements in the Baltic Sea

    Variations of the organic matter composition in the sea surface microlayer: A comparison between open ocean and upwelling sites off the Peruvian coast.

    Get PDF
    The sea surface microlayer (SML) is the thin boundary layer between the ocean and the atmosphere, making it important for air-sea exchange processes. However, little is known about what controls organic matter composition in the SML. In particular, there are only few studies available on the differences of the SML of various oceanic systems. Here, we compared the organic matter and neuston species composition in the SML and the underlying water (ULW) at 11 stations with varying distance from the coast in the Peruvian upwelling regime, a system with high emissions of climate relevant trace gases, such as N2O and CO2. In the open ocean, organic carbon, and amino acids were highly enriched in the SML compared to the ULW. The enrichment decreased at the coastal stations and vanished in the upwelling regime. At the same time, the degradation of organic matter increased from the open ocean to the upwelling stations. This suggests that in the open ocean, upward transport processes or new production of organic matter within the SML are faster than degradation processes. Phytoplankton was generally not enriched in the SML, one group though, the Trichodesmium-like TrL (possibly containing Trichodesmium), were enriched in the open ocean but not in the upwelling region indicating that they find a favorable habitat in the open ocean SML. Our data show that the SML is a distinct habitat; its composition is more similar among different systems than between SML and ULW of a single station. Generally the enrichment of organic matter is assumed to be reduced when encountering low primary production and high wind speeds. However, our study shows the highest enrichments of organic matter in the open ocean which had the lowest primary production and the highest wind speeds

    Estimation of suspended matter, organic carbon and chlorophyll-A concentrations estimation from particle size and refractive index distributions

    Get PDF
    Models of particle density and of organic carbon and chlorophyll-a intraparticle concentration were applied to particle size distributions and particle real refractive index distributions determined from flow cytometry measurements of natural seawater samples from a range of UK coastal waters. The models allowed for the estimation of suspended particulate matter, organic suspended matter, inorganic suspended matter, particulate organic carbon, and chlorophyll-a concentrations. These were then compared with independent measurements of each of these parameters. Particle density models were initially applied to a simple spherical model of particle volume, but generally overestimated independently measured values, sometimes by over two orders of magnitude. However, when the same density models were applied to a fractal model of particle volume, successful agreement was reached for suspended particulate matter and both inorganic and organic suspended matter values (RMS%E: 57.4, 148.5, and 83.1% respectively). Non-linear organic carbon and chlorophyll-a volume scaling models were also applied to a spherical model of particle volume, and after an optimization procedure achieved successful agreement with independent measurements of particulate organic carbon and chlorophyll-a concentrations (RMS%E: 45.6% and 51.8% respectively). Refractive index-based models of carbon and chlorophyll-a intraparticle concentration were similarly tested, and were also found to require a fractal model of particle volume to achieve successful agreement with independent measurements, producing RMS%E values of 50.2% and 45.2% respectively after an optimization procedure. It is further shown that the non-linear exponents of the volume scaling models are mathematically equivalent to the fractal dimensionality coefficients that link cell volume to mass concentration, reflecting the impact of non-uniform distribution of intracellular carbon within cells. Fractal models of particle volume are thus found to be essential to successful closure between results provided by models of particle mass, intraparticle carbon and chlorophyll content, and bulk measurements of suspended mass and total particulate carbon and chlorophyll when natural mixed particle populations are concerned. The results also further confirm the value of determining both size and refractive index distributions of natural particle populations using flow cytometry

    Improved determination of particulate absorption from combined filter pad and PSICAM measurements

    Get PDF
    Filter pad light absorption measurements are subject to two major sources of experimental uncertainty: the so-called pathlength amplification factor, β, and scattering offsets, o, for which previous null-correction approaches are limited by recent observations of non-zero absorption in the near infrared (NIR). A new filter pad absorption correction method is presented here which uses linear regression against point-source integrating cavity absorption meter (PSICAM) absorption data to simultaneously resolve both β and the scattering offset. The PSICAM has previously been shown to provide accurate absorption data, even in highly scattering waters. Comparisons of PSICAM and filter pad particulate absorption data reveal linear relationships that vary on a sample by sample basis. This regression approach provides significantly improved agreement with PSICAM data (3.2% RMS%E) than previously published filter pad absorption corrections. Results show that direct transmittance (T-method) filter pad absorption measurements perform effectively at the same level as more complex geometrical configurations based on integrating cavity measurements (IS-method and QFT-ICAM) because the linear regression correction compensates for the sensitivity to scattering errors in the T-method. This approach produces accurate filter pad particulate absorption data for wavelengths in the blue/UV and in the NIR where sensitivity issues with PSICAM measurements limit performance. The combination of the filter pad absorption and PSICAM is therefore recommended for generating full spectral, best quality particulate absorption data as it enables correction of multiple errors sources across both measurements

    Uncertainty budgets for liquid waveguide CDOM absorption measurements

    Get PDF
    Long path length liquid waveguide capillary cell (LWCC) systems using simple spectrometers to determine the spectral absorption by colored dissolved organic matter (CDOM) have previously been shown to have better measurement sensitivity compared to high-end spectrophotometers using 10 cm cuvettes. Information on the magnitude of measurement uncertainties for LWCC systems, however, has remained scarce. Cross-comparison of three different LWCC systems with three different path lengths (50, 100, and 250 cm) and two different cladding materials enabled quantification of measurement precision and accuracy, revealing strong wavelength dependency in both parameters. Stable pumping of the sample through the capillary cell was found to improve measurement precision over measurements made with the sample kept stationary. Results from the 50 and 100 cm LWCC systems, with higher refractive index cladding, showed systematic artifacts including small but unphysical negative offsets and high-frequency spectral perturbations due to limited performance of the salinity correction. In comparison, the newer 250 cm LWCC with lower refractive index cladding returned small positive offsets that may be physically correct. After null correction of measurements at 700 nm, overall agreement of CDOM absorption data at 440 nm was found to be within 5% root mean square percentage error

    Assessing uncertainties in scattering correction algorithms for reflective tube absorption measurements made with a WET Labs ac-9

    Get PDF
    In situ absorption measurements collected with a WET Labs ac-9 employing a reflective tube approach were scatter corrected using several possible methods and compared to reference measurements made by a PSICAM to assess performance. Overall, two correction methods performed best for the stations sampled: one using an empirical relationship between the ac-9 and PSICAM to derive the scattering error (ε) in the nearinfrared (NIR), and one where ε was independently derived from concurrent measurements of the volume scattering function (VSF). Application of the VSF-based method may be more universally applicable, although difficult to routinely apply because of the lack of commercially available VSF instrumentation. The performance of the empirical approach is encouraging as it relies only on the ac meter measurement and may be readily applied to historical data, although there are inevitably some inherent assumptions about particle composition that hinder universal applicability. For even the best performing methods, residual errors of 20% or more were commonly observed for many water types. For clear ocean waters, a conventional baseline subtraction with the assumption of negligible near-IR absorption performed as well or better than the above methods because propagated uncertainties were lower than observed with the proportional method

    Evaluation of a flow cytometry method to determine size and real refractive index distributions in natural marine particle populations

    Get PDF
    A flow cytometric (FC) method was developed to retrieve particle size distributions (PSDs) and real refractive index (nr) information in natural waters. Geometry and signal response of the sensors within the flow cytometer (CytoSense, CytoBuoy b.v., Netherlands) were characterized to form a scattering inversion model based on Mie theory. The procedure produced a mesh of diameter and nrisolines where each particle is assigned the diameter and nrvalues of the closest node, producing PSDs and particle real refractive index distributions. The method was validated using polystyrene bead standards of known diameter and polydisperse suspensions of oil with known nr, and subsequently applied to natural samples collected across a broad range of UK shelf seas. FC PSDs were compared with independent PSDs produced from data of two LISST-100X instruments (type B and type C). PSD slopes and features were found to be consistent between the FC and the two LISST-100X instruments, but LISST concentrations were found in disagreement with FC concentrations and with each other. FC nrvalues were found to agree with expected refractive index values of typical marine particle components across all samples considered. The determination of particle size and refractive index distributions enabled by the FC method has potential to facilitate identification of the contribution of individual subpopulations to the bulk inherent optical properties and biogeochemical properties of the particle population

    Stick or Dye: Evaluating a Solid Standard Calibration Approach for Point-Source Integrating Cavity Absorption Meters (PSICAM)

    Get PDF
    Together with scattering, the process of absorption determines the propagation of light within the water column. It is influenced by the concentration and composition of optically active substances (phytoplankton, chromophoric-dissolved organic matter, and non-living particles). For this reason, the absorption coefficients of a water sample can provide corresponding information. However, the accurate determination of absorption coefficients in natural waters is often difficult due to the usually low concentration of absorbing material and the errors that scattering on particles introduce in the measurements. These problems can be overcome by instruments based on integrating cavities like the point-source integrating-cavity absorption meter (PSICAM). The accuracy of PSICAM measurements is to a large degree related to the accuracy of the measurement of the reflectivity inside its cavity, as this determines its mean optical path length. A reflectivity measurement (“calibration”) is usually carried out by measuring a liquid dye (nigrosin) with known absorption coefficients, followed by bleaching and rinsing of the cavity. The procedure requires additional equipment like spectrophotometers and handling of a liquid standard. Therefore, it might be difficult or at least non-convenient under field conditions and is additionally a major obstacle for a potential automation of these systems. In the present study, an alternative calibration approach for a PSICAM is evaluated, taking advantage of a solid standard. The standard is characterized and its suitability for calibration is compared to that of a conventional, nigrosin-based reflectivity measurement. Furthermore, the application in an automated flow-through PSICAM system (HyAbS) used in the field is tested. The results show that the performance of the solid standard calibration is comparable to that of the nigrosine-based calibration. Furthermore, it improves the measurements of the automated system. Thus, due to its simplicity, the solid standard calibration might foster the use of PSICAM systems, which allow a more accurate determination of absorption coefficients in natural water samples compared to conventional spectrophotometric techniques. Furthermore, it will potentially facilitate further approaches to automate these instruments

    Measurement uncertainties in PSICAM and reflective tube absorption meters

    Get PDF
    The nature and magnitude of measurement uncertainties (precision and accuracy) associated with two approaches for measuring absorption by turbid waters are investigated here: (a) point source integrating cavity absorption meters (PSICAM), and (b) reflective tube absorption meters (AC-9 and AC-s – both WET Labs Inc., USA). Absolute measurement precision at 440 nm was quantified using standard deviations of triplicate measurements for the PSICAM and de-trended, bin averaged time series for the AC-9/s, giving comparable levels (< 0.006 m-1) for both instruments. Using data collected from a wide range of UK coastal waters, PSICAM accuracy was assessed by comparing both total non-water absorption and absorption by coloured dissolved organic material (CDOM) measured on discrete samples by two independent PSICAMs. AC-9/s performance was tested by comparing total non-water absorption measured in situ by an AC-9 and an AC-s mounted on the same frame. Results showed that the PSICAM outperforms AC-9/s instruments with regards to accuracy, with average spread in the PSICAM total absorption data of 0.006 m-1 (RMSE) compared to 0.028 m-1 for the AC-9/s devices. Despite application of a state of the art scattering correction method, the AC-9/s instruments still tend to overestimate absorption compared to PSICAM data by on average 0.014 m-1 RMSE (AC-s) and 0.043 m-1 RMSE (AC-9). This remaining discrepancy can be largely attributed to residual limitations in the correction of AC-9/s data for scattering effects and limitations in the quality of AC-9/s calibration measurements

    Correction of inter-mission inconsistencies in merged ocean colour satellite data

    Get PDF
    Consistency in a time series of ocean colour satellite data is essential when determining long-term trends and statistics in Essential Climate Variables. For such a long time series, it is necessary to merge ocean colour data sets from different sensors due to the finite life span of the satellites. Although bias corrections have been performed on merged data set products, significant inconsistencies between missions remain. These inconsistencies appear as sudden steps in the time series of these products when a satellite mission is launched into- or removed from orbit. This inter-mission inconsistency is not caused by poor correction of sensor sensitivities but by differences in the ability of a sensor to observe certain waters. This study, based on a data set compiled by the ‘Ocean Colour Climate Change Initiative’ project (OC-CCI), shows that coastal waters, high latitudes, and areas subject to changing cloud cover are most affected by coverage variability between missions. The “Temporal Gap Detection Method” is introduced, which temporally homogenises the observations per-pixel of the time series and consequently minimises the magnitude of the inter-mission inconsistencies. The method presented is suitable to be transferred to other merged satellite-derived data sets that exhibit inconsistencies due to changes in coverage over time. The results provide insights into the correct interpretation of any merged ocean colour time series
    corecore