50 research outputs found

    UV continuum emission and diagnostics of hydrogen-containing non-equilibrium plasmas

    Get PDF
    For the first time the emission of the radiative dissociation continuum of the hydrogen molecule (a3Σg+b3Σu+a^{3}\Sigma_{g}^{+} \to b^{3}\Sigma_{u}^{+} electronic transition) is proposed to be used as a source of information for the spectroscopic diagnostics of non-equilibrium plasmas. The detailed analysis of excitation-deactivation kinetics, rate constants of various collisional and radiative transitions and fitting procedures made it possible to develop two new methods of diagnostics of: (1) the ground X1Σg+X^{1}\Sigma_{g}^{+} state vibrational temperature TvibT_{\text{vib}} from the relative intensity distribution, and (2) the rate of electron impact dissociation (d[\mbox{H_{2}}]/dt)_{\text{diss}} from the absolute intensity of the continuum. A known method of determination of TvibT_{\text{vib}} from relative intensities of Fulcher-α\alpha bands was seriously corrected and simplified due to the revision of dad \to a transition probabilities and cross sections of dXd \gets X electron impact excitation. General considerations are illustrated with examples of experiments in pure hydrogen capillary-arc and H2_{2}+Ar microwave discharges.Comment: REVTeX, 25 pages + 12 figures + 9 tables. Phys. Rev. E, eprint replaced because of resubmission to journal after referee's 2nd repor

    Trace gas measurements using optically resonant cavities and quantum cascade lasers operating at room temperature

    Get PDF
    Achieving the high sensitivity necessary for trace gas detection in the midinfrared mol. fingerprint region generally requires long absorption path lengths. In addn., for wider application, esp. for field measurements, compact and cryogen free spectrometers are definitely preferable. An alternative approach to conventional linear absorption spectroscopy employing multiple pass cells for achieving high sensitivity is to combine a high finesse cavity with thermoelec. (TE) cooled quantum cascade lasers (QCLs) and detectors. We have investigated the sensitivity limits of an entirely TE cooled system equipped with an .apprx.0.5 m long cavity having a small sample vol. of 0.3 l. With this spectrometer cavity enhanced absorption spectroscopy employing a continuous wave QCL emitting at 7.66 micro m yielded path lengths of 1080 m and a noise equiv. absorption of 2 * 10-7 cm-1 Hz-1/2. The mol. concn. detection limit with a 20 s integration time was found to be 6*108 mols./cm3 for N2O and 2 * 109 mols./cm3 for CH4, which is good enough for the selective measurement of trace atm. constituents at 2.2 mbar. The main limiting factor for achieving even higher sensitivity, such as that found for larger vol. multi pass cell spectrometers, is the residual mode noise of the cavity. On the other hand the application of TE cooled pulsed QCLs for integrated cavity output spectroscopy and cavity ring-down spectroscopy (CRDS) was found to be limited by the intrinsic frequency chirp of the laser. Consequently the accuracy and advantage of an abs. internal absorption calibration, in theory inherent for CRDS expts., are not achievable

    Optimal values of rovibronic energy levels for triplet electronic states of molecular deuterium

    Full text link
    Optimal set of 1050 rovibronic energy levels for 35 triplet electronic states of D2D_2 has been obtained by means of a statistical analysis of all available wavenumbers of triplet-triplet rovibronic transitions studied in emission, absorption, laser and anticrossing spectroscopic experiments of various authors. We used a new method of the analysis (Lavrov, Ryazanov, JETP Letters, 2005), which does not need any \it a priory \rm assumptions concerning the molecular structure being based on only two fundamental principles: Rydberg-Ritz and maximum likelihood. The method provides the opportunity to obtain the RMS estimates for uncertainties of the experimental wavenumbers independent from those presented in original papers. 234 from 3822 published wavenumber values were found to be spurious, while the remaining set of the data may be divided into 20 subsets (samples) of uniformly precise data having close to normal distributions of random errors within the samples. New experimental wavenumber values of 125 questionable lines were obtained in the present work. Optimal values of the rovibronic levels were obtained from the experimental data set consisting of 3713 wavenumber values (3588 old and 125 new). The unknown shift between levels of ortho- and para- deuterium was found by least squares analysis of the a3Σg+a^3\Sigma_g^+, v=0v = 0, N=0÷18N = 0 \div 18 rovibronic levels with odd and even values of NN. All the energy levels were obtained relative to the lowest vibro-rotational level (v=0v = 0, N=0N = 0) of the a3Σg+a^3\Sigma_g^+ electronic state, and presented in tabular form together with the standard deviations of the empirical determination. New energy level values differ significantly from those available in literature.Comment: 46 pages, 9 picture

    The psychopathological and psychosocial outcome of early-onset schizophrenia: Preliminary data of a 13-year follow-up

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Relatively little is known about the long-term psychopathological and psychosocial outcome of early-onset schizophrenia. The existing literature describes more severe courses of illness in these patients compared with adult-onset schizophrenia. This article reports preliminary data of a study exploring the outcome of early-onset schizophrenia 13.4 years (mean) after first admission. Predictors for interindividual outcomes were investigated.</p> <p>Methods</p> <p>We retrospectively assessed 27 former patients (mean age at first admission 15.5 years, SD = 2.0) that were consecutively admitted to the Department of Child and Adolescent Psychiatry at the University of Wuerzburg between 1990 and 2000. A multidimensional approach was chosen to assess the outcome consisting of a mail survey including different questions about psychopathological symptoms, psychosocial parameters, and standardized self-reports (ESI and ADS).</p> <p>Results</p> <p>Concerning the psychopathological outcome, 22.2% reported having acute schizophrenic symptoms. Almost one third (30.8%) described symptoms of depression and 37.0% reported having tried to commit suicide or seriously thought about it. 77.8% of the former patients were still in outpatient treatment. Compared to the general population, the number of patients without a school graduation was relatively high (18.5%). Almost half of participants still live with their parents (48.1%) or in assisted or semi-assisted living conditions (33.3%). Only 18.5% were working in the open market.</p> <p>Conclusion</p> <p>Schizophrenia with an early onset has an unfavourable prognosis. Our retrospective study of the psychopathological and psychosocial outcome concludes with a generally poor rating.</p

    The abilities of improved schizophrenia patients to work and live independently in the community: a 10-year long-term outcome study from Mumbai, India

    Get PDF
    Background: The outcome of schizophrenia has several determinants. Socioecological factors, particularly living conditions, migration, community and culture, not only affect the level of risk but also the outcome. Mega cities around the world show a unique socioecological condition that has several challenges for mental health. The present study reports on the long-term status of patients with schizophrenia in such a mega city: Mumbai, India. Aim This study aims to reveal the long-term outcome of patients suffering from schizophrenia with special reference to clinical symptoms and social functioning. Methods: The cohort for this study was drawn from a 10-year follow-up of first episode schizophrenia. Patients having completed 10 years of consistent treatment after first hospitalisation were assessed on psychopathological and recovery criteria. Clinical as well as social parameters of recovery were evaluated. Descriptive statistics with 95% confidence intervals are provided. Results: Of 200 patients recruited at the beginning of this study, 122 patients (61%) were present in the city of Mumbai at the end of 10-year follow-up study period. Among 122 available patients, 101 patients (50.5%) were included in the assessment at the end of 10-year follow-up study period, 6 patients (3.0%) were excluded from the study due to changed diagnosis, and 15 patients (7.5%) were excluded due to admission into long-term care facilities. This indicates that 107 out of 122 available patients (87.7%) were living in the community with their families. Out of 101 (50.5%) patients assessed at the end of 10 years, 61 patients (30.5%) showed improved recovery on the Clinical Global Impression Scale, 40 patients (20%) revealed no improvement in the recovery, 43 patients (72.9%) were able to live independently, and 24 patients (40%) were able to find employment. Conclusions: With 10 years of treatment, the recovery rate among schizophrenia patients in Mumbai was 30.5%. Among the patients, 87.7% of patients lived in the community, 72.9% of patients lived independently, and 40% of patients obtained employment. However, 60% of patients were unable to return to work, which highlights the need for continued monitoring and support to prevent the deterioration of health in these patients. It is likely that socioecological factors have played a role in this outcome

    Using quantum cascade lasers with resonant optical cavities as a diagnostic tool

    No full text
    Absorption spectroscopy based on optical resonators is known to be a very sensitive diagnostic technique. For many years the infrared spectral range could not be employed, because of the lack of suitable radiation sources with the required power and tunability. Recent advances in semiconductor laser technology, in particular the advent of quantum cascade lasers (QCL) provides new possibilities for highly sensitive and selective detection of molecular species. Cavity Enhanced Absorption Spectroscopy (CEAS) with a thermoelectrically (TE) cooled cw QCL emitting at 7.66 µm and employing a ~0.5 m long cavity yielded effective path lengths of 1080 m and a sensitivity of 2 x 10-7 cm-1 Hz-1/2, mainly limited by incomplete averaging over cavity resonances. The molecular concentration detection limit with a 20 s integration time was found to be 6 x 108 molecules/cm3 for N2O and 2 x 10 9 molecules/cm3 for CH4 which is good enough for the selective measurement of trace atmospheric constituents at 2.2 mbar. © 2009 IOP Publishing Lt

    Using quantum cascade lasers with resonant optical cavities as a diagnostic tool

    No full text
    Absorption spectroscopy based on optical resonators is known to be a very sensitive diagnostic technique. For many years the infrared spectral range could not be employed, because of the lack of suitable radiation sources with the required power and tunability. Recent advances in semiconductor laser technology, in particular the advent of quantum cascade lasers (QCL) provides new possibilities for highly sensitive and selective detection of molecular species. Cavity Enhanced Absorption Spectroscopy (CEAS) with a thermoelectrically (TE) cooled cw QCL emitting at 7.66 µm and employing a ~0.5 m long cavity yielded effective path lengths of 1080 m and a sensitivity of 2 x 10-7 cm-1 Hz-1/2, mainly limited by incomplete averaging over cavity resonances. The molecular concentration detection limit with a 20 s integration time was found to be 6 x 108 molecules/cm3 for N2O and 2 x 10 9 molecules/cm3 for CH4 which is good enough for the selective measurement of trace atmospheric constituents at 2.2 mbar. © 2009 IOP Publishing Lt

    Involvement of mouse mammary tumor virus in spontaneous and hormone-induced mammary tumors in low-mammary-tumor mouse strains.

    No full text
    The involvement of the mouse mammary tumor virus (MTV) in spontaneous and hormone-induced mammary tumors in low-mammary-tumor mouse strains was studied by comparing the amounts of MTV RNA and MTV DNA sequences in mammary tumors and other tissues of mice with an without hormonal treatments. The following results were obtained. (i) Mammary tumors which appeared in C3H mice as a result of an infection with MTV contained more MTV DNA compared with noninfected organs; these mammary tumors also contained more MTV RNA than was present in lactating mammary gland cells. (ii) Hormonal stimulation by administration of excessive amounts of prolactin via hypophyseal isografts in C3Hf and O20 mice resulted in an increased expression of MTV RNA in the mammary glands. This elevated level of MTV RNA expression was, however, not maintained in the hormone-induced mammary tumors. (iii) Spontaneous mammary tumors in BALB/c mice contained similar levels of MTV DNA and MTV RNA sequences as were found in other cells of these animals
    corecore