20 research outputs found

    Improving Remote Sensing of Aerosol Optical Depth over Land by Polarimetric Measurements at 1640 nm: Airborne Test in North China

    No full text
    An improved aerosol retrieval algorithm based on the Advanced Multi-angular Polarized Radiometer (AMPR) is presented to illustrate the utility of additional 1640-nm observations for measuring aerosol optical depth (AOD) over land using look-up table approaches. Spectral neutrality of the polarized surface reflectance over visible to short-wavelength infrared bands is verified, and the 1640-nm measurements corrected for atmospheric effects are used to estimate the polarized surface reflectance at shorter wavelengths. The AMPR measurements over the Beijing-Tianjin-Hebei region in north China reveal that the polarized surface reflectance of 670, 865 and 1640 nm are highly correlated with correlation slopes close to one (0.985 and 1.03) when the scattering angle is less than 145°. The 1640-nm measurements are then employed to estimate polarized surface reflectance at shorter wavelengths for each single viewing direction, which are then used to improve the retrieval of AOD over land. The comparison between AMPR retrievals and ground-based Sun-sky radiometer measurements during three experimental flights illustrates that this approach retrieves AOD at 865 nm with uncertainties ranging from 0.01 to 0.06, while AOD varies from 0.05 to 0.17

    Improving Remote Sensing of Aerosol Microphysical Properties by Near-Infrared Polarimetric Measurements Over Vegetated Land: Information Content Analysis

    No full text
    International audienceWhile polarimetric measurements contain valuable information regarding aerosol microphysical properties, polarization data in the near-infrared (NIR) bands have not been widely utilized. This paper evaluates whether the aerosol property information contents from single-viewing satellite polarimetric measurements at 1,610 and 2,250 nm can be used to improve the retrieval of aerosol parameters over vegetated land, in combination with shorter-wavelength bands (490, 670, and 870 nm). The a priori information and errors for the analysis are derived by assuming that the surface reflectance at visible wavelengths can be derived from the top of atmosphere at 2,250 nm. The information content in the synthetic data set is investigated for 10 aerosol parameters characterizing the columnar aerosol volumes (V0f and V0c), particle size distributions (refff, vefff, reffc, and veffc), and refractive indices (mrf, mif, mrc, and mic) for the fine- and coarse-mode aerosol models, respectively, and one parameter C characterizing the surface polarization. The results indicate that the degrees of freedom for signal can be increased by at least 2 with the addition of NIR measurements and that one to three additional parameters could be further retrieved with significantly decreased uncertainties. In addition, the 1,610 nm band is necessary for the simultaneous retrieval of V0f, mrf, and refff for the fine mode dominated aerosols, while the 1,610 and 2,250 nm bands are both indispensable for retrieving V0f, V0c, mrc, refff, and reffc in tandem for the coarse mode dominated aerosols. The analysis also reveals that C could be further retrieved by including scalar radiance and that measurement errors have significantly larger influences on the retrieval uncertainties than model errors

    A Current Sensing Biosensor for BOD Rapid Measurement

    No full text
    In order to improve the practicality of the rapid biochemical oxygen demand (BOD) method, a highly sensitive rapid detection method for BOD that is based on establishing the correlation between current and dissolved oxygen (DO) was developed. In this experiment, Bacillus subtilis was used as the test microorganism, and the embedding method was used to achieve quantitative fixation of microorganisms, which could increase the content of microorganisms and prolong the service life of the biological element. The conductivity (COND) probe is used as a sensing element, so that the testing value can be read every second. In the program, the moving average method is used to process the collected data so that the value can be read every minute. National standard samples were detected to test the accuracy and stability of the method. The results showed that relative error and analytical standard deviations were less than 5%. Different polluted water was tested to evaluate its application range. The results showed that relative error was less than 5%. The results of the method are consistent with the results of the wastewater sample obtained by the BOD5 standard method. The proposed rapid BOD current sensing biosensor method should be promising in practical application of wastewater monitoring

    Retrieval of the Fine-Mode Aerosol Optical Depth over East China Using a Grouped Residual Error Sorting (GRES) Method from Multi-Angle and Polarized Satellite Data

    No full text
    The fine-mode aerosol optical depth (AODf) is an important parameter for the environment and climate change study, which mainly represents the anthropogenic aerosols component. The Polarization and Anisotropy of Reflectances for Atmospheric Science coupled with Observations from a Lidar (PARASOL) instrument can detect polarized signal from multi-angle observation and the polarized signal mainly comes from the radiation contribution of the fine-mode aerosols, which provides an opportunity to obtain AODf directly. However, the currently operational algorithm of Laboratoire d’Optique Atmosphérique (LOA) has a poor AODf retrieval accuracy over East China on high aerosol loading days. This study focused on solving this issue and proposed a grouped residual error sorting (GRES) method to determine the optimal aerosol model in AODf retrieval using the traditional look-up table (LUT) approach and then the AODf retrieval accuracy over East China was improved. The comparisons between the GRES retrieved and the Aerosol Robotic Network (AERONET) ground-based AODf at Beijing, Xianghe, Taihu and Hong_Kong_PolyU sites produced high correlation coefficients (r) of 0.900, 0.933, 0.957 and 0.968, respectively. The comparisons of the GRES retrieved AODf and PARASOL AODf product with those of the AERONET observations produced a mean absolute error (MAE) of 0.054 versus 0.104 on high aerosol loading days (AERONET mean AODf at 865 nm = 0.283). An application using the GRES method for total AOD (AODt) retrieval also showed a good expandability for multi-angle aerosol retrieval of this method

    Retrieval of Aerosol Optical Depth Using the Empirical Orthogonal Functions (EOFs) Based on PARASOL Multi-Angle Intensity Data

    No full text
    Aerosol optical depth (AOD) is a widely used aerosol optical parameter in atmospheric physics. To obtain this parameter precisely, many institutions plan to launch satellites with multi-angle measurement sensors, but one important step in aerosol retrieval, the estimation of surface reflectance, is still a pressing issue. This paper presents an AOD retrieval method based on the multi-angle intensity data from the Polarization and Anisotropy of Reflectances for Atmospheric Science coupled with Observations from a Lidar (PARASOL) platform using empirical orthogonal functions (EOFs), which can be universally applied to multi-angle observations. The function of EOFs in this study is to estimate surface intensity contributions, associated with aerosol lookup tables (LUTs), so that the retrieval of AOD can be implemented. A comparison of the retrieved AODs for the Beijing, Xianghe, Taihu, and Hongkong_PolyU sites with those from the Aerosol Robotic Network (AERONET) ground-based observations produced high correlation coefficients (r) of 0.892, 0.915, 0.831, and 0.897, respectively, while the corresponding root mean square errors (RMSEs) are 0.095, 0.093, 0.099, and 0.076, respectively

    Improving Remote Sensing of Aerosol Optical Depth over Land by Polarimetric Measurements at 1640 nm: Airborne Test in North China

    No full text
    An improved aerosol retrieval algorithm based on the Advanced Multi-angular Polarized Radiometer (AMPR) is presented to illustrate the utility of additional 1640-nm observations for measuring aerosol optical depth (AOD) over land using look-up table approaches. Spectral neutrality of the polarized surface reflectance over visible to short-wavelength infrared bands is verified, and the 1640-nm measurements corrected for atmospheric effects are used to estimate the polarized surface reflectance at shorter wavelengths. The AMPR measurements over the Beijing-Tianjin-Hebei region in north China reveal that the polarized surface reflectance of 670, 865 and 1640 nm are highly correlated with correlation slopes close to one (0.985 and 1.03) when the scattering angle is less than 145°. The 1640-nm measurements are then employed to estimate polarized surface reflectance at shorter wavelengths for each single viewing direction, which are then used to improve the retrieval of AOD over land. The comparison between AMPR retrievals and ground-based Sun-sky radiometer measurements during three experimental flights illustrates that this approach retrieves AOD at 865 nm with uncertainties ranging from 0.01 to 0.06, while AOD varies from 0.05 to 0.17

    In-Flight Relative Radiometric Calibration of a Wide Field of View Directional Polarimetric Camera Based on the Rayleigh Scattering over Ocean

    No full text
    The directional polarimetric camera (DPC) is a Chinese satellite sensor with a large field of view (FOV) (±50° both along-track and cross-track) and a high spatial resolution (about 3.3 km at nadir) that operates in a sun-synchronous orbit. It is a difficult task to calibrate the in-flight relative radiometric variation of the sensors with such a wide FOV. In this study, a new method based on Rayleigh scattering over the ocean is developed to estimate the radiometric sensitivity variation over the whole FOV of DPC. Firstly, the theoretical uncertainty of the method is analyzed to calibrate the relative radiometric response. The calibration uncertainties are about 2–6.9% (depending on the wavelength) when the view zenith angle (VZA) is 0° and decrease to about 1–3.8% when VZA increases to 70°. Then, the method is applied to evaluate the long-term radiometric drift of the DPC. It is found that the radiometric response of DPC/GaoFen-5 over the whole FOV is progressively drifting over time. The sensitivity at shorter bands decreases more strongly than longer bands, and at the central part of the optics decreases more strongly than the marginal part. During the 14 months (from March 2019 to April 2020) of operational running in-orbit, the DPC radiometric responses of 443 nm, 490 nm, 565 nm, and 670 nm bands drifted by about 4.44–23.08%, 4.75–16.22%, 3.86–9.81%, and 4.7–16.86%, respectively, from the marginal to the central part of the FOV. The radiometric sensitivity has become more stable since January 2020. The monthly radiometric drift is separated into the relative radiometric part and the absolute radiometric part. The relative radiometric drift of DPC is found to be smoothly varying with VZA, which can be parameterized as a polynomial function via VZA. At last, the temporal radiometric drift of DPC/GaoFen-5 is corrected by combining the relative and absolute radiometric coefficients. The correction is convincing by cross calibration with MODIS/Aqua observation over the desert sites and improving the aerosol retrievals. The Rayleigh method in this study is efficient for the radiometric sensitivity calibration of wide FOV satellite sensors

    An Improved Aerosol Optical Depth Retrieval Algorithm for Multiangle Directional Polarimetric Camera (DPC)

    No full text
    The DPC is a multiangle sensor that detects atmospheric parameters. However, the retrieval of high-precision and high-spatial-resolution aerosol products from the DPC remains a great challenge due to the ill-posed nature of the problem. Thus, a novel aerosol optical depth (AOD) retrieval algorithm was proposed using visible surface reflectance relationships (VISRRs). The VISRR algorithm accounts for the surface anisotropy and needs neither a shortwave infrared band nor a surface reflectance database that can retrieve AOD over dark and bright land cover. Firstly, moderate-resolution imaging spectroradiometer (MODIS) surface reflectance (MYD09) products were used to derive the preceding surface reflectance relationships (SRRs), which are related to surface types, scattering angle, and normalized difference vegetation index (NDVI). Furthermore, to solve the problem of the NDVI being susceptible to the atmosphere, an innovative method based on an iterative atmospheric correction was proposed to provide a realistic NDVI. The VISRR algorithm was then applied to the thirteen months of DPC multiangle data over the China region. AOD product comparison between the DPC and MODIS showed that they had similar spatial distribution, but the DPC had both high spatial resolution and coverage. The validation between the ground-based sites and the retrieval results showed that the DPC AOD performed best, with a Pearson correlation coefficient (R) of 0.88, a root mean square error (RMSE) of 0.17, and a good fraction (Gfrac) of 62.7%. Then, the uncertainties regarding the AOD products were discussed for future improvements. Our results revealed that the VISRR algorithm is an effective method for retrieving reliable, simultaneously high-spatial-resolution and full-surface-coverage AOD data with good accuracy
    corecore