593 research outputs found

    Optimal Dark Hole Generation via Two Deformable Mirrors with Stroke Minimization

    Full text link
    The past decade has seen a significant growth in research targeted at space based observatories for imaging exo-solar planets. The challenge is in designing an imaging system for high-contrast. Even with a perfect coronagraph that modifies the point spread function to achieve high-contrast, wavefront sensing and control is needed to correct the errors in the optics and generate a "dark hole". The high-contrast imaging laboratory at Princeton University is equipped with two Boston Micromachines Kilo-DMs. We review here an algorithm designed to achieve high-contrast on both sides of the image plane while minimizing the stroke necessary from each deformable mirror (DM). This algorithm uses the first DM to correct for amplitude aberrations and the second DM to create a flat wavefront in the pupil plane. We then show the first results obtained at Princeton with this correction algorithm, and we demonstrate a symmetric dark hole in monochromatic light

    Limitations of the removal of cyanide from coking wastewater by ozonation and by the hydrogen peroxideozone process

    Get PDF
    The purpose of this study is to compare the efficiency of ozonation and the hydrogen peroxide–ozone process for the removal of cyanide from coking wastewater. The most efficient oxidation process is combined with coagulation–flocculation–decantation and lime–soda ash softening pretreatments. The oxidation in aqueous solution and industrial wastewater (at pH 9.5–12.3) by O3 was carried out using a range of concentration of consumed O3 from 10 to 290 mg/L. A molar ratio of H2O2/O3 from 0.1 to 5.2 with different concentrations of O3 constants was used for the H2O2-O3 process. The maximum cyanide removal obtained in coking wastewater was 90% using a mass ratio of O3/CN– of 9.5. Using lower concentrations of O3, cyanide is not removed and can even be generated due to the presence of other cyanide precursor organic micropollutants in the industrial matrix. The concentration of O3 is reduced to half for the same cyanide removal efficiency if the pretreatments are applied to reduce the carbonate and bicarbonate ions. The cyanide removal efficiency in coking wastewater is not improved if the O3 is combined with the H2O2. However, the preliminary cyanide removal treatment in aqueous solution showed an increase in the cyanide removal efficiency for the H2O2-O3 process

    Design of PIAA coronagraphs over square apertures

    Full text link
    The purpose of this paper is to present the results of a theoretical study pertaining to the feasibility of PIAA units using Deformable Mirrors. We begin by reviewing the general derivation of the design equations driving PIAA. We then show how to solve these equations for square apertures and show the performance of pure PIAA systems in the ray optics regime. We tie these design equations into the study of edge diffraction effects, and provide a general expression for the field after a full propagation through a PIAA coronagraph. Third, we illustrate how a combination of pre and post apodisers yields to a contrast of 10^10 even in the presence of diffractive effects, for configuration with neither wavefront errors or wavefront control. Finally we present novel PIAA configurations over square apertures which circumvent the constraints on the manufacturing of PIAA optics by inducing the apodisation with two square Deformable Mirrors (DM). Such solutions rely on pupil size smaller than currently envisioned static PIAA solutions and thus require aggressive pre and post-apodizing screens in order to mitigate for diffractive effect between the two mirrors. As a result they are associated to significant loss in performance, throughput in particular

    Physical activity in centenarians beyond cut-point-based accelerometer metrics

    Get PDF
    This study described and compared physical activity (PA) characteristics at the end of the human lifespan using conventional cut-point-based versus cut-point-free accelerometer metrics. Eighteen institutionalized centenarians (101.5 ± 2.1 years, 72.2% female, 89% frail) wore the wrist GENEActiv accelerometer for 7 days. Conventional metrics, such as time spent in light-intensity PA (LiPA) and moderate-to-vigorous intensity PA (MVPA) were calculated according to published cut-points for adults and older adults. The following cut-point-free metrics were evaluated: average acceleration, intensity gradient and Mx metrics. Depending on the cut-point, centenarians accumulated a median of 15–132 min/day of LiPA and 3–15 min/day of MVPA. The average acceleration was 9.2 mg [Q1: 6.7 mg–Q3: 12.6 mg] and the intensity gradient was −3.19 [−3.34–−3.12]. The distribution of Z-values revealed positive skew for MVPA, indicating a potential floor effect, whereas the skew magnitude was attenuated for cut-point-free metrics such as intensity gradient or M5. However, both cut-point-based and cut-point-free metrics were similarly positively associated with functional independence, cognitive and physical capacities. This is the first time that PA has been described in centenarians using cut-point-free metrics. Our results suggest that new analytical approaches could overcome cut-point limitations when studying the oldest-old. Future studies using these new cut-point-free PA metrics are warranted to provide more complete and comparable information across groups and populations

    High-contrast imager for Complex Aperture Telescopes (HiCAT): 1. Testbed design

    Get PDF
    Searching for nearby habitable worlds with direct imaging and spectroscopy will require a telescope large enough to provide angular resolution and sensitivity to planets around a significant sample of stars. Segmented telescopes are a compelling option to obtain such large apertures. However, these telescope designs have a complex geometry (central obstruction, support structures, segmentation) that makes high-contrast imaging more challenging. We are developing a new high-contrast imaging testbed at STScI to provide an integrated solution for wavefront control and starlight suppression on complex aperture geometries. We present our approach for the testbed optical design, which defines the surface requirements for each mirror to minimize the amplitude-induced errors from the propagation of out-of-pupil surfaces. Our approach guarantees that the testbed will not be limited by these Fresnel propagation effects, but only by the aperture geometry. This approach involves iterations between classical ray-tracing optical design optimization, and end-to-end Fresnel propagation with wavefront control (e.g. Electric Field Conjugation / Stroke Minimization). The construction of the testbed is planned to start in late Fall 2013.Comment: Proc. of the SPIE 8864, 10 pages, 3 figures, Techniques and Instrumentation for Detection of Exoplanets V

    Sex differences in drug-induced changes in ventricular repolarization

    Get PDF
    Introduction: Heart rate corrected QT (QTc) interval prolongation is a predictor of drug-induced torsade de pointes, a potentially fatal ventricular arrhythmia that disproportionately affects women. This study assesses whether there are sex differences in the ECG changes induced by four different hERG potassium channel blocking drugs. Methods and results: Twenty-two healthy subjects (11 women) received a single oral dose of dofetilide, quinidine, ranolazine, verapamil and placebo in a double-blind 5-period crossover study. ECGs and plasma drug concentrations were obtained at pre-dose and at 15 time-points post-dose. Dofetilide, quinidine and ranolazine prolonged QTc. There were no sex differences in QTc prolongation for any drug, after accounting for differences in exposure. Sex differences in any ECG biomarker were observed only with dofetilide, which caused greater J-Tpeakc prolongation (p=0.045) but lesser Tpeak-Tend prolongation (p=0.006) and lesser decrease of T wave amplitude (p=0.003) in women compared to men. Conclusions: There were no sex differences in QTc prolongation for any of the studied drugs. Moreover, no systematic sex differences in other drug-induced ECG biomarker changes were observed in this study. This study suggests that the higher torsade risk in women compared to men is not due to a larger concentration-dependent QTc prolongation

    Comprehensive T wave Morphology Assessment in a Randomized Clinical Study of Dofetilide, Quinidine, Ranolazine, and Verapamil

    Get PDF
    Background Congenital long QT syndrome type 2 (abnormal hERG potassium channel) patients can develop flat, asymmetric, and notched T waves. Similar observations have been made with a limited number of hERG-blocking drugs. However, it is not known how additional calcium or late sodium block, that can decrease torsade risk, affects T wave morphology. Methods and Results Twenty-two healthy subjects received a single dose of a pure hERG blocker (dofetilide) and 3 drugs that also block calcium or sodium (quinidine, ranolazine, and verapamil) as part of a 5-period, placebo-controlled cross-over trial. At pre-dose and 15 time-points post-dose, ECGs and plasma drug concentration were assessed. Patch clamp experiments were performed to assess block of hERG, calcium (L-type) and late sodium currents for each drug. Pure hERG block (dofetilide) and strong hERG block with lesser calcium and late sodium block (quinidine) caused substantial T wave morphology changes (P<0.001). Strong late sodium current and hERG block (ranolazine) still caused T wave morphology changes (P<0.01). Strong calcium and hERG block (verapamil) did not cause T wave morphology changes. At equivalent QTc prolongation, multichannel blockers (quinidine and ranolazine) caused equal or greater T wave morphology changes compared with pure hERG block (dofetilide). Conclusions T wave morphology changes are directly related to amount of hERG block; however, with quinidine and ranolazine, multichannel block did not prevent T wave morphology changes. A combined approach of assessing multiple ion channels, along with ECG intervals and T wave morphology may provide the greatest insight into drug-ion channel interactions and torsade de pointes risk

    Estimation of the second ventilatory threshold through ventricular repolarization profile analysis

    Get PDF
    Under the hypothesis that sympathetic control of ventricular repolarization may change once the second ventilatory threshold (VT2) has been reached, a novel methodology for non-invasive VT2 estimation based on the analysis of the T wave from the electrocardiogram (ECG) is proposed, and potential underlying physiological mechanisms are suggested. 25 volunteers (33.4 ± 5.2 years) underwent an incremental power cycle ergometer test (25 W/minute). During the test, respiratory gas exchange and multi-lead ECG were acquired. The former was employed to determine VT2, used here as a reference, whereas the latter was used to compute the temporal profiles of an index of ventricular repolarization instability (dT) and its low-frequency (LF) oscillations (LFdT). The sudden increases observed in dT and LFdT profiles above an established heart rate threshold were employed to derive VT2 estimates, referred to as VT2dT and VT2LFdT, respectively. Estimation errors of -4.7 ± 25.2 W were obtained when considering VT2dT. Errors were lower than the one-minute power increment of 25 W in 68% of the subjects and lower than 50 W in 89.5% of them. When using VT2LFdT, estimation error was of 15.3 ± 32.4 W. Most of the subjects shared common characteristic dT and LFdT profiles, which could be reflecting changes in the autonomic control of ventricular repolarization before and after reaching VT2. The analysis of ventricular repolarization dynamics during exercise allows non-invasive ECG-based estimation of VT2, possibly in relation to changes in the autonomic control of ventricular electrical activity when VT2 is reached
    • …
    corecore