184 research outputs found

    Povidone-iodine Irrigation - A Possible Alternative To Lead Extraction

    Get PDF
    Pocket infection and erosion remain the commonest (class 1) indication for pacemaker (PM) or implantable cardiac defibrillator (ICD) lead extraction. However, tranvenous lead extraction is not without significant risk of serious complications, particularly in patients with chronically implanted leads or ICD leads specifically. The paucity of cardiologists adequately experienced to undertake this high-risk procedure also means that its availability is limited to relatively few specialist institutions, yet more conservative 'lead-preserving' treatment options have not been well-reported. We describe the first reported case of a chronically eroded and infected ICD generator, managed conservatively with 5-days of povidone-iodine closed irrigation, followed by re-implantation of a new ICD on the contralateral side. With satisfactory long-term follow-up, this successfully averted the need for lead extraction in our elderly patient. We advocate the need for formal prospective evaluation of conservative therapeutic strategies of PM and ICD pocket infections. Although not gold standard, it provides an important therapeutic alternative in resource-limited areas

    Staphylococcus aureus from patients with chronic rhinosinusitis show minimal genetic association between polyp and non-polyp phenotypes

    Get PDF
    Background: Staphylococcus aureus has a high prevalence in chronic rhinosinusitis (CRS) patients and is suggested to play a more etiopathogenic role in CRS patients with nasal polyps (CRSwNP), a severe form of the CRS spectrum with poorer surgical outcomes. We performed a microbial genome-wide association study (mGWAS) to investigate whether S. aureus isolates from CRS patients have particular genetic markers associated with CRS with nasal polyps (CRSwNP) or CRS without nasal polyps (CRSsNP). Methods: Whole genome sequencing was performed on S. aureus isolates collected from 28 CRSsNP and 30 CRSwNP patients. A mGWAS approach was employed using large-scale comparative genomics to identify genetic variation within our dataset. Results: Considerable genetic variation was observed, with >90,000 single nucleotide polymorphisms (SNPs) sites identified. There was little correlation with CRS subtype based on SNPs and Insertion/Delection (Indels). One indel was found to significantly correlate with CRSwNP and occurred in the promoter region of a bacitracin transport system ATP-binding protein. Additionally, two variants of the highly variable superantigen-like (SSL) proteins were found to significantly correlate with each CRS phenotype. No significant association with other virulence or antibiotic resistance genes were observed, consistent with previous studies. Conclusion: To our knowledge this study is the first to use mGWAS to investigate the contribution of microbial genetic variation to CRS presentations. Utilising the most comprehensive genome-wide analysis methods available, our results suggest that CRS phenotype may be influenced by genetic factors other than specific virulence mechanisms within the S. aureus genome

    The effects of computerised cognitive training on post-CABG delirium and cognitive change: A prospective randomised controlled trial

    Get PDF
    Background: Cognitive impairments, including delirium, are common after coronary artery bypass grafting (CABG). Improving cognition pre- and post-operatively using computerised cognitive training (CCT) may be an effective approach to improve cognitive outcomes in CABG patients. Objectives: Investigate the effect of remotely supervised CCT on cognitive outcomes, including delirium, in older adults undergoing CABG surgery. Methods: Thirty-six participants, were analysed in a single-blinded randomised controlled trial (CCT Intervention: n = 18, Control: n = 18). CCT was completed by the intervention group pre-operatively (every other day, 45–60-minute sessions until surgery) and post-operatively, beginning 1-month post-CABG (3 x 45–60-minute sessions/week for 12-weeks), while the control group maintained usual care plus weekly phone calls. Cognitive assessments were conducted pre- and post-operatively at multiple follow-ups (discharge, 4-months and 6-months). Post-operative delirium incidence was assessed daily until discharge. Cognitive change data were calculated at each follow-up for each cognitive test (Addenbrooke’s Cognitive Examination III and CANTAB; z-scored). Results: Adherence to the CCT intervention (completion of three pre-operative or 66% of post-operative sessions) was achieved in 68% of pre-CABG and 59% of post-CABG participants. There were no statistically significant effects of CCT on any cognitive outcome, including delirium incidence. Conclusion: Adherence to the CCT program was comparatively higher than previous feasibility studies, possibly due to the level of supervision and support provided (blend of face-to-face and home-based training, with support phone calls). Implementing CCT interventions both pre- and post-operatively is feasible in those undergoing CABG. No statistically significant benefits from the CCT interventions were identified for delirium or cognitive function post-CABG, likely due to the sample size available (study recruitment greatly impacted by COVID-19). It also may be the case that multimodal intervention would be more effective

    Validation of cardiovascular magnetic resonance assessment of pericardial adipose tissue volume

    Get PDF
    © 2009 Nelson et al; licensee BioMed Central Ltd.Background Pericardial adipose tissue (PAT) has been shown to be an independent predictor of coronary artery disease. To date its assessment has been restricted to the use of surrogate echocardiographic indices such as measurement of epicardial fat thickness over the right ventricular free wall, which have limitations. Cardiovascular magnetic resonance (CMR) offers the potential to non-invasively assess total PAT, however like other imaging modalities, CMR has not yet been validated for this purpose. Thus, we sought to describe a novel technique for assessing total PAT with validation in an ovine model. Methods 11 merino sheep were studied. A standard clinical series of ventricular short axis CMR images (1.5T Siemens Sonata) were obtained during mechanical ventilation breath-holds. Beginning at the mitral annulus, consecutive end-diastolic ventricular images were used to determine the area and volume of epicardial, paracardial and pericardial adipose tissue. In addition adipose thickness was measured at the right ventricular free wall. Following euthanasia, the paracardial adipose tissue was removed from the ventricle and weighed to allow comparison with corresponding CMR measurements. Results There was a strong correlation between CMR-derived paracardial adipose tissue volume and ex vivo paracardial mass (R2 = 0.89, p < 0.001). In contrast, CMR measurements of corresponding RV free wall paracardial adipose thickness did not correlate with ex vivo paracardial mass (R2 = 0.003, p = 0.878). Conclusion In this ovine model, CMR-derived paracardial adipose tissue volume, but not the corresponding and conventional measure of paracardial adipose thickness over the RV free wall, accurately reflected paracardial adipose tissue mass. This study validates for the first time, the use of clinically utilised CMR sequences for the accurate and reproducible assessment of pericardial adiposity. Furthermore this non-invasive modality does not use ionising radiation and therefore is ideally suited for future studies of PAT and its role in cardiovascular risk prediction and disease in clinical practiceAdam J Nelson, Matthew I Worthley, Peter J Psaltis, Angelo Carbone, Benjamin K Dundon, Rae F Duncan, Cynthia Piantadosi, Dennis H Lau, Prashanthan Sanders, Gary A Wittert and Stephen G Worthle

    Factors associated with cognitive decline and delirium after transcatheter aortic valve implantation: Preliminary evidence

    Get PDF
    Background: Transcatheter aortic valve implantation (TAVI) has become the standard for treating severe symptomatic aortic stenosis in those with prohibitive surgical risk. Cognitive complications, including delirium and cognitive decline are common following TAVI, yet an understanding of pre-procedural factors associated with these outcomes is lacking. This prospective observational study set out to identify geriatric pre-procedural factors associated with post-procedural delirium and cognitive decline in patients undergoing TAVI. / Methods: Cognitive outcomes of TAVI patients aged ≥60 years (N=32) were measured over one-year post-TAVI. Pre-procedural measures included frailty, gait, visual symptoms, voice pitch, dysphagia, blink rate, mood, and sleep. Primary outcomes were post-procedural delirium and cognitive decline. / Results: Delirium was present in 25% of patients over two days following TAVI and 26% experienced cognitive decline in the year post-TAVI. Daily physical activity was a protective factor against cognitive decline, and worse baseline visual memory was associated with delirium. While non-significant and with very large confidence intervals, moderate to large effect sizes were found for associations between slowed gait speed, pre-existing atrial fibrillation, and dysphagia for delirium, and slower gait speed, higher blink rate, pre-existing atrial fibrillation for cognitive decline. / Conclusion: Though underpowered, measures of considerable effect size were identified (although non-significant and with large variability). In larger studies, these novel geriatric factors could further be explored for predicting cognitive complications following TAVI. Improvement of risk prediction for cognitive decline and delirium following TAVI could assist with early identification of those at risk, informing clinical decision-making and allowing for targeted intervention to reduce post-procedural incidence of these complications

    Discovery of kilohertz quasi-periodic oscillations in the Z source GX 340+0

    Get PDF
    We have discovered two simultaneous kHz quasi-periodic oscillations (QPOs) in the Z source GX 340+0 with the Rossi X-ray Timing Explorer. The X-ray hardness-intensity and color-color diagram each show a full Z-track, with an extra limb branching off the flaring branch of the Z. Both peaks moved to higher frequencies when the mass accretion rate increased. The two peaks moved from 247 +/- 6 and 567 +/- 39 Hz at the left end of the horizontal branch to 625 +/- 18 and 820 +/- 19 Hz at its right end. The higher frequency peak's rms amplitude (5-60 keV) and FWHM decreased from ~5% and 383 +/- 135 Hz to ~2%, and 145 +/- 62 Hz, respectively. The rms amplitude and FWHM of the lower peak were consistent with being constant near 2.5 % and 100 Hz. The kHz QPO separation was consistent with being constant at 325 +/- 10 Hz. Simultaneous with the kHz QPOs we detected the horizontal branch oscillations (HBO) and its second harmonic, at frequencies between 20 and 50 Hz, and 38 and 69 Hz, respectively. The normal branch oscillations were only detected on the upper and middle normal branch, and became undetectable on the lower normal branch. The HBO frequencies do not fall within the range predicted for Lense-Thirring (LT) precession, unless either the ratio of the neutron star moment of inertia to neutron star mass is at least 4, 10^45 gcm^2/M_sun, the frequencies of the HBO are in fact the sub-harmonic oscillations, or the observed kHz peak difference is half the spin frequency and not the spin frequency. During a 1.2 day gap between two observations, the Z-track in the hardness-intensity diagram moved to higher count rates by about 3.5%. Comparing data before and after this shift, we find that the HBO properties are determined by position on the Z-track and not directly by count rate or X-ray colors.Comment: 12 pages including 4 figures. Accepted for publication in ApJ Letter

    Detection of intrinsic source structure at ~3 Schwarzschild radii with Millimeter-VLBI observations of SAGITTARIUS A*

    Get PDF
    We report results from very long baseline interferometric (VLBI) observations of the supermassive black hole in the Galactic center, Sgr A*, at 1.3 mm (230 GHz). The observations were performed in 2013 March using six VLBI stations in Hawaii, California, Arizona, and Chile. Compared to earlier observations, the addition of the APEX telescope in Chile almost doubles the longest baseline length in the array, provides additional {\it uv} coverage in the N-S direction, and leads to a spatial resolution of \sim30 μ\muas (\sim3 Schwarzschild radii) for Sgr A*. The source is detected even at the longest baselines with visibility amplitudes of \sim4-13% of the total flux density. We argue that such flux densities cannot result from interstellar refractive scattering alone, but indicate the presence of compact intrinsic source structure on scales of \sim3 Schwarzschild radii. The measured nonzero closure phases rule out point-symmetric emission. We discuss our results in the context of simple geometric models that capture the basic characteristics and brightness distributions of disk- and jet-dominated models and show that both can reproduce the observed data. Common to these models are the brightness asymmetry, the orientation, and characteristic sizes, which are comparable to the expected size of the black hole shadow. Future 1.3 mm VLBI observations with an expanded array and better sensitivity will allow a more detailed imaging of the horizon-scale structure and bear the potential for a deep insight into the physical processes at the black hole boundary.Comment: 11 pages, 5 figures, accepted to Ap

    Pseudomonas aeruginosa Exoprotein-Induced Barrier Disruption Correlates With Elastase Activity and Marks Chronic Rhinosinusitis Severity

    Get PDF
    Background:Pseudomonas aeruginosa causes severe chronic respiratory diseases and is associated with recalcitrant chronic rhinosinusitis (CRS). P. aeruginosa exoproteins contain virulence factors and play important roles in the pathogenicity of P. aeruginosa, however their role in CRS pathophysiology remains unknown.Methods: We isolated P. aeruginosa clinical isolates (CIs) and obtained clinical information from 21 CRS patients. Elastase activity of the CIs was measured at different phases of growth. Primary human nasal epithelial cells (HNECs) were cultured at air-liquid interface (ALI) and challenged with P. aeruginosa exoproteins or purified elastase, followed by measuring Transepithelial Electrical Resistance (TEER), permeability of FITC-dextrans, western blot, and immunofluorescence.Results: 14/21 CIs had a significant increase in elastase activity in stationary phase of growth. There was a highly significant strong correlation between the in vitro elastase activity of P. aeruginosa CIs with mucosal barrier disruption evidenced by increased permeability of FITC-dextrans (r = 0.95, p = 0.0004) and decreased TEER (r = −0.9333, P &lt; 0.01) after 4 h of challenge. Western blot showed a significant degradation of ZO-1, Occludin and β-actin in relation to the elastase activity of the exoproteins. There was a highly significant correlation between the in vitro elastase activity of P. aeruginosa CIs and CRS disease severity (for log phase, r = 0.5631, p = 0.0097; for stationary phase, r = 0.66, p = 0.0013) assessed by CT imaging of the paranasal sinuses.Conclusion: Our results implicate P. aeruginosa exoproteins as playing a major role in the pathophysiology of P. aeruginosa associated CRS by severely compromising mucosal barrier structure and function

    3D-printed micro lens-in-lens for in vivo multimodal microendoscopy

    Get PDF
    Published online: March 1, 2022Multimodal microendoscopes enable co-located structural and molecular measurements in vivo, thus providing useful insights into the pathological changes associated with disease. However, different optical imaging modalities often have conflicting optical requirements for optimal lens design. For example, a high numerical aperture (NA) lens is needed to realize high-sensitivity fluorescence measurements. In contrast, optical coherence tomography (OCT) demands a low NA to achieve a large depth of focus. These competing requirements present a significant challenge in the design and fabrication of miniaturized imaging probes that are capable of supporting high-quality multiple modalities simultaneously. An optical design is demonstrated which uses two-photon 3D printing to create a miniaturized lens that is simultaneously optimized for these conflicting imaging modalities. The lens-in-lens design contains distinct but connected optical surfaces that separately address the needs of both fluorescence and OCT imaging within a lens of 330 µm diameter. This design shows an improvement in fluorescence sensitivity of >10x in contrast to more conventional fiber-optic design approaches. This lens-in-lens is then integrated into an intravascular catheter probe with a diameter of 520 µm. The first simultaneous intravascular OCT and fluorescence imaging of a mouse artery in vivo is reported.Jiawen Li, Simon Thiele, Rodney W. Kirk, Bryden C. Quirk, Ayla Hoogendoorn, Yung Chih Chen, Karlheinz Peter, Stephen J. Nicholls, Johan W. Verjans, Peter J. Psaltis, Christina Bursill, Alois M. Herkommer, Harald Giessen, and Robert A. McLaughli
    corecore