26 research outputs found

    Primary hyperparathyroidism diagnosed after surgical ablation of a costal mass mistaken for giant-cell bone tumor: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Primary hyperparathyroidism is a common endocrine disorder characterized by elevated parathyroid hormone levels, which cause continuous osteoclastic bone resorption. Giant cell tumor of bone is an expansile osteolytic tumor that contains numerous osteoclast-like giant cells. There are many similarities in the radiological and histological features of giant cell tumor of bone and brown tumor. This is a rare benign focal osteolytic process most commonly caused by hyperparathyroidism.</p> <p>Case presentation</p> <p>We report the unusual case of a 40-year-old Caucasian woman in which primary hyperparathyroidism was diagnosed after surgical ablation of a costal mass. The mass was suspected of being neoplastic and histopathology was compatible with a giant cell tumor of bone. On the basis of the biochemical results (including serum calcium, phosphorous and intact parathyroid hormone levels) primary hyperparathyroidism was suspected and a brown tumor secondary to refractory hyperparathyroidism was diagnosed.</p> <p>Conclusions</p> <p>Since giant cell tumor is a bone neoplasm that has major implications for the patient, the standard laboratory tests in patients with bone lesions are important for a correct diagnosis.</p

    Non-invasive estimation of cardiac index in healthy volunteers.

    No full text
    The primary objective was to non-invasively measure the cardiac index (CI) and associated haemodynamic parameters of healthy volunteers and their changes with age. This was a single centre, prospective, observational study of healthy volunteers aged between 20 and 59 years, using the ClearSight™ (Edwards Life Sciences, Irvine, CA, USA) device. We recorded 514 observations in 97 participants. The mean CI was 3.5 l/min/m2 (95% confidence interval [95% CI] 3.4 to 3.7 l/min/m2). The mean stroke volume index (SVI) was 47 ml/m2 (95% CI 45 to 49 ml/m2) and the mean systemic vascular resistance index was 2,242 dyne.s/cm5/m2 (95% CI 2,124 to 2,365 dyne.s/cm5/m2). There was an inverse linear relationship between increasing age and CI (P 2 (95% CI  -0.032 to -0.056 l/min/m2) per year. This change was mostly due to a decrease in SVI of 0.45 ml/m2 (95% CI 0.32 to 0.57 ml/m2) per year (P 2 and declines by approximately 40 ml/min/m2 per year, mostly due to a decline in stroke volume (SV). These findings have significant implications regarding the clinical interpretation of haemodynamic parameters and the application of these results to individual patients

    Comparison of conformal radiation therapy techniques within the dynamic radiotherapy project 'Dynarad'

    No full text
    The objective of the dynamic radiotherapy project 'Dynarad' within the European Community has been to compare and grade treatment techniques that are currently applied or being developed at the participating institutions. Cervical cancer was selected as the tumour site on the grounds that the involved organs at risk, mainly the rectum and the bladder, are very close to the tumour and partly located inside the internal target volume. In this work, a solid phantom simulating the pelvic anatomy was used by institutions in Belgium, France, Greece, Holland, Italy, Sweden and the United Kingdom. The results were evaluated using both biological and physical criteria. The main purpose of this parallel evaluation is to test the value of biological and physical evaluations in comparing treatment techniques. It is demonstrated that the biological objective functions allow a much higher conformality and a more clinically relevant scoring of the outcome. Often external beam treatment techniques have to be combined with intracavitary therapy to give clinically acceptable results. However, recent developments can reduce or even eliminate this need by delivering more conformal dose distributions using intensity modulated external dose delivery. In these cases the reliability of the patient set-up procedure becomes critical for the effectiveness of the treatmen
    corecore