34 research outputs found

    Bacterial anterior chamber contamination after phacoemulsification and polymethylmethacrylate or silicone intraocular lens implantation

    Get PDF
    OBJETIVO: Avaliar a contaminação bacteriana da câmara anterior, após facoemulsificação não complicada, com tamanhos diferentes de incisões e lentes intra-oculares. MÉTODOS: Foi realizado estudo prospectivo randomizado, de 80 olhos de 80 pacientes, submetidos à facoemulsificação sob anestesia tópica, distribuídos aleatoriamente em dois grupos iguais. No grupo A foram alocados os pacientes submetidos à cirurgia com incisão de 3,0 mm, lente intra-ocular dobrável de silicone implantadas com injetor. No grupo B os pacientes foram submetidos à cirurgia com incisão de 5,8 mm e implante de lente intra-ocular de polimetilmetacrilato de peça única, com pinça. Ao final de cada cirurgia, uma amostra do líquido da câmara anterior foi colhida e semeada em meios de cultura para bactérias. RESULTADOS: A cultura do líquido da câmara anterior foi positiva em 2,5% dos casos do grupo A e em 5,0% do grupo B. Não houve diferença estatisticamente significante entre os dois grupos (chi2 = 0, 380, p> 0,05). CONCLUSÃO: O implante de lente intra-ocular através de incisão menor, não resultou em menor contaminação da câmara anterior na cirurgia de facoemulsificação.PURPOSE: To evaluate bacterial anterior chamber contamination following uncomplicated phacoemulsification with differents sizes of incisions. METHODS: Prospective randomized study, 80 eyes, 80 patients divided into two groups, were submitted to phacoemulsification with topical anaesthesia. In group A, with 40 patients, surgery was perfomed with 3.0 mm incision and silicone intraocular lens implant with injector. In group B the surgery was done with 5.8 mm incision and polymethylmethacrylate intraocular lens implant with forceps. Anterior chamber aspirate was taken for culture upon completion of surgery in each case. RESULTS: Anterior chamber cultures were positive in 2.5% of the cases in group A, and 5.0% in group B (chi-square test = 0.380, p>0.05), frequencies of contamination were not significantly different. CONCLUSION: Intraocular lens implant through a smaller incision did not decrease anterior chamber contamination in phacoemulsification

    Using of Cells Analyser® software in the study of image of corneal specular microscope endothelial samples

    Get PDF
    OBJETIVOS: Conhecer diferenças entre o número de células, área endotelial avaliada e erro amostral, comparando amostras endoteliais de uma única imagem endotelial, com amostras endoteliais constituídas pelo número de células e imagens, orientadas por software específico. MÉTODOS: Foi realizado estudo transversal, comparando as amostras endoteliais com e sem a intervenção do software. A amostra foi composta de 157 olhos. Foram criados 2 grupos: Grupo 1: composto pelos dados amostrais da primeira imagem dos exames; Grupo 2: composto pelos dados amostrais que consideram o número de imagens necessárias para que o exame seja considerado completo pelo software Cells Analyzer PAT. REC. (Grau de confiança 95% e erro relativo 0,05). Os dados amostrais comparados foram número de células contadas, área da amostra endotelial e erro amostral. Utilizou-se o teste t Student bicaudal, para amostras pareadas, com nível de 99% (p<0,01). RESULTADOS: 157 (52,69%) exames necessitaram de mais de uma imagem endotelial para que se superasse o número mínimo de células endoteliais necessárias. Evidenciou-se diferença estatisticamente significativa, do número de células das amostras endoteliais (p= 4x10-24), da área endotelial avaliada (p= 2x10-18) e do erro amostral (p= 1x10-21) entre o Grupo 1 e o Grupo 2. CONCLUSÃO: O estudo dos dados amostrais sem e com a intervenção do software Cells Analyser®, mostraram-se estatisticamente diferentes, com amostras maiores e erros amostra.PURPOSE: To describe differences between number of cells, evaluated endothelial area and relative error comparing endothelial samples from one endothelial image with endothelial samples obtained by guidance of a specific software, with number of cells and images as many as necessary. METHODS: A transversal study was performed, comparing the endothelial samples with and without intervention of the software. The sample consisted of 157 eyes. They were divided into 2 groups. Group 1 consisted of data of the first image and group 2 consisted of data from as many images as necessary for a complete examination guided by the Cells Analyser software (95% confidence interval and 0.05 relative error). The evaluated data were number of counted cells, equivalent evaluated field (mm²) and relative error. Student's t test with 99% confidence interval (p<0.01) was used. RESULTS: The compared data showed statistically significant differences between groups 1 and 2 in cell count (p=4x10-24), evaluated endothelial field (p=2x10-18) and relative error (p=1x10-21). CONCLUSION: The study of the sample data with or without the analysis of the software Cells Analyzer® showed statistically significant differences showing clearly the importance of using it in order to obtain representative, standardized and reproducible results of specular microscopy examination

    Acuidade visual em implantes bilaterais de lentes intra-oculares monofocais e multifocais

    Full text link
    OBJETIVO: Comparar a acuidade visual de longe e perto de pacientes submetidos à facoemulsificação binocular não simultânea com implante de lentes multifocais ou monofocais. MÉTODOS: Foram selecionados 20 pacientes com lentes multifocais bilaterais e outros 20 pacientes com lentes monofocais também bilaterais, com acuidade visual sem correção melhor ou igual a 0,63 (20/30), medidos separadamente, nos três primeiros meses de pós-operatório. Foi medida a acuidade visual para longe e perto com e sem correção e testes de sensibilidade ao contraste e ofuscamento. RESULTADOS: A acuidade visual sem correção para longe no grupo das monofocais teve média de 0,82 (DP&plusmn; 0,16) e no grupo das multifocais, 0,94 (DP&plusmn;0,12), valor de p 0,001. Os dois grupos de lentes tiveram visão com correção para longe igual a 1. No grupo das multifocais, 75% tiveram J1 e 100% tiveram J3 ou melhor sem correção. No grupo das lentes monofocais, 10% tiveram J1 e 70% tiveram J3 ou melhor sem correção. Não houve diferença significante na avaliação com o teste de sensibilidade ao contraste entre os grupos pesquisados. No teste de ofuscamento, os dois grupos tiveram redução da visão, que foi mais acentuada no grupo dos pacientes com lentes multifocais. CONCLUSÃO: A acuidade visual para longe com correção nos pacientes com implante multifocal foi semelhante a dos pacientes com implantes monofocais, embora a acuidade visual para perto no grupo em que foi implantado lente multifocal foi bastante superior ao grupo da lente monofocal. A sensibilidade ao contraste manteve-se semelhante nos dois grupos, já o ofuscamento ("glare test") no grupo multifocal foi maior que no grupo monofocal.<br>PURPOSE: To compare distant and near visual acuity between patients submitted to bilateral nonsimultaneous facoemulsification and implantation of multifocal or monofocal intraocular lenses (IOL). METHODS: Twenty patients with bilateral multifocal IOL and 20 patients with monofocal IOL with best corrected visual acuity (BCVA) of 20/30 or better, in separate measurements, within the first 3 months after surgery. Distant and near visual acuities with and without correction, contrast sensitivity and glare test were registered. RESULTS: The uncorrected distant visual acuity of the monofocal group had a mean of 0.82 (SD&plusmn;0.16) and 0.9 (SD &plusmn;0.12) in the multifocal group, p-value 0,001. Both groups had BCVA of 1. In the multifocal group, 75% had Jaegger (J) 1 and 100% had J3 or better for uncorrected near visual acuity (UNVA). In the monofocal group 10% had J1 and 70% had J3 or better for UNVA. There was no significant difference between both groups regarding the contrast sensitivity test. Both groups had vision reduction in the glare test, which was more pronounced in the multifocal group. CONCLUSIONS: The corrected distant visual acuity in the multifocal and monofocal groups showed to be similar, although UNVA in the multifocal group was better than in the monofocal group. The contrast sensitivity test showed similar results in both groups, but the glare test showed more intense discomfort in the multifocal group

    Conjunctival bacilloscopy in leprosy diagnosis and follow-up

    Get PDF
    OBJETIVO: Estudar a presença do Mycobacterium leprae na conjuntiva ocular e validar a baciloscopia de conjuntiva como teste diagnóstico e de acompanhamento da hanseníase. MÉTODOS: Foi realizado raspado de conjuntiva tarsal superior em 52 pacientes portadores de hanseníase recém-diagnosticados (26 multibacilares e 26 paucibacilares) no período de julho a setembro de 2004 na clínica Oculistas Associados de Brasília e foram analisados os resultados da baciloscopia de conjuntiva a fim de compará-la com a baciloscopia da linfa (padrão-ouro). RESULTADOS: A avaliação da correlação entre o índice baciloscópico da conjuntiva (IBC) e índice baciloscópico da linfa (IBL) medida pelo coeficiente de correlação linear de Pearson é 76,3% (p<0,01). O teste qui-quadrado de Pearson também evidenciou associação entre IBL e IBC (p<0,01). O índice k (medida de concordância kappa de Cohen) foi de 0,615 (p<0,01). Dos 26 casos com IBL positivos, 17 tinham IBC positivo, demonstrando uma sensibilidade do IBC de 65,4% (IC 95% - 0,519-0,690). Dos 26 casos de IBL negativo, 25 eram IBC negativo, revelando especificidade de 96,2% (IC 95% - 0,826-0,998). O valor preditivo positivo é de 94,4% e o valor preditivo negativo é de 73,5%. A acurácia do teste é de 80,8%. A razão de verossimilhança é 17. O tempo médio de negativação do bacilo no olho é de 5 meses (IC 95% - 3,57-6,43). CONCLUSÃO: Sugerimos a utilização da combinação de baciloscopia da linfa e baciloscopia de conjuntiva para confirmação do diagnóstico e classificação da hanseníase e da baciloscopia de conjuntiva para acompanhamento do tratamento poliquimioterápico na hanseníase.PURPOSE: To identify Mycobacterium leprae in ocular conjunctivae and evaluate conjunctival bacilloscopy as leprosy diagnosis and follow-up test. METHODS: We used the superior tarsal conjunctiva scraping technique in 52 newly diagnosed leprosy patients between July and September 2004 at the "Oculistas Associados de Brasília", in Brasília, DF, Brazil, and compared the conjunctival bacilloscopy with skin bacilloscopy. RESULTS: Both the conjunctival bacilloscopy index (CBI) and skin bacilloscopy index (SBI) showed correlation since Pearson's r and Cohen kappa measure of agreement were respectively 76.3% (p<0.01) and 0.615 (p<0.01). Pearson chi-square also evidenced the correlation (p<0.01). Comparison of CBI and SBI (17 cases of positive CBI out of 26 SBI) gives a sensitivity of 65.4% (CI95% - 0.519-0.690); 25 cases of positive CBI out of 26 cases of negative SBI give a specificity of 96.2% (CI95% - 0.826-0.998); positive predictive value of 94.4%; negative predictive value of 73.5%, and accuracy of 80.8%. Likelihood ratio was 17. Mean time to eliminate the bacilli from conjunctiva was 5 months (CI95% - 3.57-6.43). CONCLUSION: We suggest the use of conjunctival bacilloscopy in addition with skin bacilloscopy to confirm leprosy diagnosis. Conjunctival bacilloscopy may also be useful for treatment follow-up in leprosy

    Effects of reading, exercise and exercise combined with reading on intraocular pressure for patients sustaining primary glaucoma (open angle) or ocular hypertension, both clinically controlled with topic medication

    Get PDF
    OBJETIVO: Verificar a pressão intra-ocular (Po) em indivíduos usuários de análogos de prostaglandina, prostamida ou beta-bloqueador em portadores de glaucoma primário de ângulo aberto ou hipertensão ocular após leitura, exercício e exercício sob leitura. MÉTODOS: Quarenta indivíduos (79 olhos), subdivididos em 5 grupos: G1 (portadores de hipertensão arterial e glaucoma ou hipertensão ocular usando análogos de prostaglandinas ou prostamidas); G2 (portadores de hipertensão arterial e glaucoma ou hipertensão ocular usando beta-bloqueador); G3 (indivíduos sem hipertensão arterial e portadores de glaucoma ou hipertensão ocular em uso de análogos de prostaglandinas ou prostamidas); G4 (indivíduos sem hipertensão arterial e portadores de glaucoma ou hipertensão ocular em uso de beta-bloqueador) e G5 (indivíduos sem hipertensão arterial e sem glaucoma ou hipertensão ocular), tiveram a pressão intra-ocular verificada antes e após realizarem leitura, exercício e exercício sob leitura. Cada teste foi realizado em dia distinto e sempre no período vespertino. RESULTADOS: Não houve diferença estatisticamente significante na média da pressão intra-ocular inicial e final nos diferentes grupos do estudo quando submetidos à leitura, exercício e exercício sob leitura. CONCLUSÃO: Ler e fazer exercícios individualmente ou concomitantemente, não representa fator de agravo da pressão intra-ocular em portadores de glaucoma primário de ângulo aberto ou hipertensão ocular em usuários de análogos de prostaglandinas ou prostamidas ou beta-bloqueador.PURPOSE: To check intraocular pressure (IOP) in individuals using prostaglandin, prostamide or beta-blocker analogues, who sustain either primary open angle glaucoma or ocular hypertension after reading, exercise or exercise combined with reading. METHODS: 40 individuals (79 eyes), subdivided in to five groups: G1 (with arterial hypertension and either glaucoma or ocular hypertension, all users of prostaglandin or prostamide analogues); G2 (with arterial hypertension and either glaucoma or ocular hypertension, all users of beta-blockers); G3 (not sustaining arterial hypertension but suffering from either glaucoma or ocular hypertension, all users of prostaglandin or prostamide analogues); G4 (not sustaining arterial hypertension but suffering from either glaucoma or ocular hypertension, all users of beta-blockers) and G5 (not sustaining arterial hypertension and also not suffering from either glaucoma or ocular hypertension) had their intraocular pressure checked before and after undergoing reading, exercise, and exercise combined with reading. Each type of test was conducted in a different day, always in the afternoon. RESULTS: No significant statistical difference has been noticed between the initial and final intraocular pressure mean in the different groups, when reading, performing exercises or exercises combined with reading. CONCLUSION: To read and to work out - either separately or jointly - does not pose an aggravating factor to the intraocular pressure of patients with primary open glaucoma or ocular hypertension, using prostaglandin, prostamide or beta-blocker analogues
    corecore