20 research outputs found

    TAM Model for E-Health Implementation in Rural Areas of Uttarakhand, Post Covid-19 Pandemic: TAM Model for E-Health Implementation: A Study of Rural Areas of Uttarakhand During Post Covid

    No full text
    Objective: The present study aim to find out the factors that has an influence and impacts the actual use of e-Health during post COVID-19 pandemic on the lines of TAM (technology acceptance model) and further suggest ways for effective implementation and adoption of e-Health by the rural patients. Design & Setting: The study was conducted on a total of 243 rural patients who had experienced e-Health services. Structural Equation Modeling has been used for analysis of data. Results: The analysis revealed that ‘perceived usefulness’, ‘perceived ease of use’, ‘privacy’ and ‘trust’, all had considerable impact on the ‘intention to use’ which further significantly  impacts the ‘actual use’. Conclusion: Using in-depth interviews, both patients and physicians, practice of evidence-based e-Health interventions was identified for effective implementation and adoption of e-Health, which further helps to provides an equitable healthcare services to both urban and rural population

    The role of graft T-cell size in patients receiving alemtuzumab serotherapy for non-malignant disorders: results of an institutional protocol

    No full text
    Abstract Although graft T cells assist in engraftment, mediate antiviral immune-reconstitution, and cause graft-versus-host disease, graft size is not determined by T-cell content of the graft. The conventional method of graft size determination based on CD34+ cells with alemtuzumab serotherapy is associated with delayed immune reconstitution, contributing to an increased risk of viral infections and graft failure. Alemtuzumab, a long half-life anti-CD52 monoclonal antibody is a robust T-cell depleting serotherapy, and relatively spares memory-effector T cells compared to naïve T cells. We therefore hypothesized that graft size based on T-cell content in patients receiving peripheral blood stem cell graft with alemtuzumab serotherapy would facilitate immune-reconstitution without increasing the risk of graft-versus-host disease. We retrospectively analysed twenty-six consecutive patients with non-malignant disorders grafted using alemtuzumab serotherapy and capping of graft T cells to a maximum of 600 million/kg. The graft T-cell capping protocol resulted in early immune-reconstitution without increasing the risk of severe graft-versus-host disease. Graft T-cell content correlated with CD4+ T-cell reconstitution and acute graft-versus-host disease. The course of CMV viraemia was predictable without recurrence and associated with early T-cell recovery. No patient developed chronic graft-versus-host disease. Overall survival at one year was 100% and disease-free survival was 96% at a median of 899 days (range: 243–1562). Graft size determined by peripheral blood stem cell graft T-cell content in patients receiving alemtuzumab serotherapy for non-malignant disorders is safe and leads to early T-cell immune-reconstitution with excellent survival outcomes

    Taste masking of ondansetron hydrochloride by polymer carrier system and formulation of rapid-disintegrating tablets

    No full text
    The purpose of this research was to mask the intensely bitter taste of ondansetron HCl and to formulate a rapiddisintegrating tablet (RDT) of the taste-maske drug. Taste masking was done by complexing ondansetron HCl with aminoalkyl methacrylate copolymer (Eudragit EPO) in different ratios by the precipitation method. Drug-polymer complexes (DPCs) were tested for drug content, in vitro taste in simulated salivary fluid (SSF) of pH 6.2, and molecular property. Complex that did not release drug in SSF was considered taste-masked and selected for formulation RDTs. The complex with drug-polymer ratio of 8∶2 did not show drug release in SSF; therefore, it was selected. The properties of tablets such as tensile strength, wetting time, water absorption ratio, in vitro disintegration time, and disintegration in the oral cavity were investigated to elucidate the wetting and disintegration characteristics of tablets. Polyplasdone XL-10 7% wt/wt gave the minimum disintegration time. Tablets of batch F4 containing spray-dried mannitol and microcrystalline cellulose in the ratio 1∶1 and 7% wt/wt Polyplasdone XL-10 showed faster disintegration, within 12.5 seconds, than the marketed tablet (112 seconds). Good correlation between in vitro disintegration behavior and in the oral cavity was recognized. Taste evaluation of RDT in human volunteers revealed considerable taste masking with the degree of bitterness below threshold value (0.5) ultimately reaching to 0 within 15 minutes, whereas ondansetron HCl was rated intensely bitter with a score of 3 for 10 minutes. Tablets of batch F4 also revealed rapid drug release (t90, 60 seconds) in SGF compared with marketed formulation (t90, 240 seconds;P<.01). Thus, results conclusively demonstrated successful masking of taste and rapid disintegration of the formulated tablets in the oral cavity

    The CMS Barrel Calorimeter Response to Particle Beams from 2 to 350 GeV/c

    No full text
    The response of the CMS barrel calorimeter (electromagnetic plus hadronic) to hadrons, electrons and muons over a wide momentum range from 2 to 350 GeV/c has been measured. To our knowledge, this is the widest range of momenta in which any calorimeter system has been studied. These tests, carried out at the H2 beam-line at CERN, provide a wealth of information, especially at low energies. The analysis of the differences in calorimeter response to charged pions, kaons, protons and antiprotons and a detailed discussion of the underlying phenomena are presented. We also show techniques that apply corrections to the signals from the considerably different electromagnetic (EB) and hadronic (HB) barrel calorimeters in reconstructing the energies of hadrons. Above 5 GeV/c, these corrections improve the energy resolution of the combined system where the stochastic term equals 84.7±\pm1.6%\% and the constant term is 7.4±\pm0.8%\%. The corrected mean response remains constant within 1.3%\% rms

    Transverse momentum and pseudorapidity distributions of charged hadrons in pp collisions at (s)\sqrt(s) = 0.9 and 2.36 TeV

    Get PDF
    Measurements of inclusive charged-hadron transverse-momentum and pseudorapidity distributions are presented for proton-proton collisions at sqrt(s) = 0.9 and 2.36 TeV. The data were collected with the CMS detector during the LHC commissioning in December 2009. For non-single-diffractive interactions, the average charged-hadron transverse momentum is measured to be 0.46 +/- 0.01 (stat.) +/- 0.01 (syst.) GeV/c at 0.9 TeV and 0.50 +/- 0.01 (stat.) +/- 0.01 (syst.) GeV/c at 2.36 TeV, for pseudorapidities between -2.4 and +2.4. At these energies, the measured pseudorapidity densities in the central region, dN(charged)/d(eta) for |eta| < 0.5, are 3.48 +/- 0.02 (stat.) +/- 0.13 (syst.) and 4.47 +/- 0.04 (stat.) +/- 0.16 (syst.), respectively. The results at 0.9 TeV are in agreement with previous measurements and confirm the expectation of near equal hadron production in p-pbar and pp collisions. The results at 2.36 TeV represent the highest-energy measurements at a particle collider to date

    Measurement of the charge ratio of atmospheric muons with the CMS detector

    No full text
    We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/ c to 1 TeV/ c . The surface flux ratio is measured to be 1.2766±0.0032(stat.)±0.0032(syst.) , independent of the muon momentum, below 100 GeV/ c . This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments.We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/c to 1 TeV/c. The surface flux ratio is measured to be 1.2766 \pm 0.0032(stat.) \pm 0.0032 (syst.), independent of the muon momentum, below 100 GeV/c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments

    Transverse-momentum and pseudorapidity distributions of charged hadrons in pppp collisions at s\sqrt{s} = 7 TeV

    No full text
    Charged-hadron transverse-momentum and pseudorapidity distributions in proton-proton collisions at s=7\sqrt{s} = 7~TeV are measured with the inner tracking system of the CMS detector at the LHC. The charged-hadron yield is obtained by counting the number of reconstructed hits, hit-pairs, and fully reconstructed charged-particle tracks. The combination of the three methods gives a charged-particle multiplicity per unit of pseudorapidity \dnchdeta|_{|\eta| < 0.5} = 5.78\pm 0.01\stat\pm 0.23\syst for non-single-diffractive events, higher than predicted by commonly used models. The relative increase in charged-particle multiplicity from s=0.9\sqrt{s} = 0.9 to 7~TeV is 66.1\%\pm 1.0\%\stat\pm 4.2\%\syst. The mean transverse momentum is measured to be 0.545\pm 0.005\stat\pm 0.015\syst\GeVc. The results are compared with similar measurements at lower energies.Charged-hadron transverse-momentum and pseudorapidity distributions in proton-proton collisions at sqrt(s) = 7 TeV are measured with the inner tracking system of the CMS detector at the LHC. The charged-hadron yield is obtained by counting the number of reconstructed hits, hit-pairs, and fully reconstructed charged-particle tracks. The combination of the three methods gives a charged-particle multiplicity per unit of pseudorapidity, dN(charged)/d(eta), for |eta| < 0.5, of 5.78 +/- 0.01 (stat) +/- 0.23 (syst) for non-single-diffractive events, higher than predicted by commonly used models. The relative increase in charged-particle multiplicity from sqrt(s) = 0.9 to 7 TeV is 66.1% +/- 1.0% (stat) +/- 4.2% (syst). The mean transverse momentum is measured to be 0.545 +/- 0.005 (stat) +/- 0.015 (syst) GeV/c. The results are compared with similar measurements at lower energies

    Measurement of the B+B^+ Production Cross Section in pp Collisions at s\sqrt{s} = 7 TeV

    No full text
    Measurements of the total and differential cross sections with respect to transverse momentum and rapidity for B+ mesons produced in pp collisions at s\sqrt{s} = 7 TeV are presented. The data correspond to an integrated luminosity of 5.8 inverse picobarns collected by the CMS experiment operating at the LHC. The exclusive decay B+J/ψK+B^+ \to J/\psi K^+, with the J/ψJ/\psi decaying to an oppositely charged muon pair, is used to detect B+ mesons and to measure the production cross section as a function of the transverse momentum and rapidity of the B. The total cross section for p_t(B) > 5 GeV and |y(B)| 5 GeV and |y(B)| < 2.4 is measured to be 28.1 +/- 2.4 +/- 2.0 +/- 3.1 microbarns, where the first uncertainty is statistical, the second is systematic, and the last is from the luminosity measurement
    corecore