186 research outputs found
Control of Clinical Pathogens by the Haemolymph of Paratelphusa hydrodromous, a Freshwater Crab
In the present study, effort has been made to find the antimicrobial activity of haemolymph collected from freshwater crab, Paratelphusa hydrodromous. The haemolymph collected was tested for antimicrobial assay by disc diffusion method against clinical pathogens. Five bacterial species, namely, Escherichia coli, Klebsiella pneumonia, Proteus mirabilis, Pseudomonas aeruginosa, Staphylococcus aureus, and five fungal strains, namely and Aspergillus flavus, Aspergillus fumigatus, Aspergillus niger, Rhizopus sp., and Mucor sp., were selected for the study. The result shows a strong response of haemolymph against the clinical pathogens which confirms the immune mechanism of the freshwater crab
Holography of Charged Dilaton Black Holes
We study charged dilaton black branes in . Our system involves a
dilaton coupled to a Maxwell field with dilaton-dependent
gauge coupling, . First, we find the solutions for
extremal and near extremal branes through a combination of analytical and
numerical techniques. The near horizon geometries in the simplest cases, where
, are Lifshitz-like, with a dynamical exponent
determined by . The black hole thermodynamics varies in an interesting
way with , but in all cases the entropy is vanishing and the specific
heat is positive for the near extremal solutions. We then compute conductivity
in these backgrounds. We find that somewhat surprisingly, the AC conductivity
vanishes like at T=0 independent of . We also explore the
charged black brane physics of several other classes of gauge-coupling
functions . In addition to possible applications in AdS/CMT, the
extremal black branes are of interest from the point of view of the attractor
mechanism. The near horizon geometries for these branes are universal,
independent of the asymptotic values of the moduli, and describe generic
classes of endpoints for attractor flows which are different from .Comment: 33 pages, 3 figures, LaTex; v2, references added; v3, more refs
added; v4, refs added, minor correction
Risk profile of the RET A883F germline mutation: an international collaborative study
Context: The A883F germline mutation of the REarranged during Transfection proto-oncogene causes multiple endocrine neoplasia 2B. In the revised American Thyroid Association (ATA) guidelines for the management of medullary thyroid carcinoma (MTC) the A883F mutation has been reclassified from the highest to high risk level, although no well-defined risk profile for this mutation exists. Objective: To create a risk profile for the A883F mutation for appropriate classification in the ATA risk levels. Design: Retrospective analysis. Setting: International collaboration. Patients: Included were 13 A883F carriers. Intervention: The intervention was thyroidectomy. Main Outcome Measures: Earliest age of MTC, regional lymph node metastases, distant metastases, age-related penetrance of MTC and pheochromocytoma (PHEO), overall and disease-specific survival and biochemical cure rate. Results: One and three carriers were diagnosed at age 7-9 years (median 7.5) with a normal thyroid and C-cell hyperplasia, respectively. Nine carriers had MTC diagnosed at age 10-39 years (median 19). The earliest age of MTC, regional lymph node and distant metastasis were 10, 20, 20 years, respectively. Fifty percent penetrance of MTC and PHEO was achieved by age 19 and 34 years, respectively. Five- and 10-year survival (both overall and disease-specific) were 88% and 88%, respectively. Biochemical cure for MTC at latest follow-up was achieved in 63% (5/8 carriers) with pertinent data. Conclusions: MTC of A883F carriers seems to have a more indolent natural course compared to that of M918T carriers. Our results support the classification of the A883F mutation in the ATA high risk level
The Evolution of Extracellular Matrix
We present a perspective on the molecular evolution of the extracellular matrix (ECM) in metazoa that draws on research publications and data from sequenced genomes and expressed sequence tag libraries. ECM components do not function in isolation, and the biological ECM system or âadhesomeâ also depends on posttranslational processing enzymes, cell surface receptors, and extracellular proteases. We focus principally on the adhesome of internal tissues and discuss its origins at the dawn of the metazoa and the expansion of complexity that occurred in the chordate lineage. The analyses demonstrate very high conservation of a core adhesome that apparently evolved in a major wave of innovation in conjunction with the origin of metazoa. Integrin, CD36, and certain domains predate the metazoa, and some ECM-related proteins are identified in choanoflagellates as predicted sequences. Modern deuterostomes and vertebrates have many novelties and elaborations of ECM as a result of domain shuffling, domain innovations and gene family expansions. Knowledge of the evolution of metazoan ECM is important for understanding how it is built as a system, its roles in normal tissues and disease processes, and has relevance for tissue engineering, the development of artificial organs, and the goals of synthetic biology
Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading
neutrino oscillation measurements over the lifetime of the experiment. In this
work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in
the neutrino sector, and to resolve the mass ordering, for exposures of up to
100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed
uncertainties on the flux prediction, the neutrino interaction model, and
detector effects. We demonstrate that DUNE will be able to unambiguously
resolve the neutrino mass ordering at a 3 (5) level, with a 66
(100) kt-MW-yr far detector exposure, and has the ability to make strong
statements at significantly shorter exposures depending on the true value of
other oscillation parameters. We also show that DUNE has the potential to make
a robust measurement of CPV at a 3 level with a 100 kt-MW-yr exposure
for the maximally CP-violating values \delta_{\rm CP}} = \pm\pi/2.
Additionally, the dependence of DUNE's sensitivity on the exposure taken in
neutrino-enhanced and antineutrino-enhanced running is discussed. An equal
fraction of exposure taken in each beam mode is found to be close to optimal
when considered over the entire space of interest
First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2Ă 6.1Ă 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP\u27s performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP\u27s successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design
Snowmass Neutrino Frontier: DUNE Physics Summary
The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, international collaboration of scientists and engineers to have unique capability to measure neutrino oscillation as a function of energy in a broadband beam, to resolve degeneracy among oscillation parameters, and to control systematic uncertainty using the exquisite imaging capability of massive LArTPC far detector modules and an argon-based near detector. DUNE's neutrino oscillation measurements will unambiguously resolve the neutrino mass ordering and provide the sensitivity to discover CP violation in neutrinos for a wide range of possible values of ÎŽCP. DUNE is also uniquely sensitive to electron neutrinos from a galactic supernova burst, and to a broad range of physics beyond the Standard Model (BSM), including nucleon decays. DUNE is anticipated to begin collecting physics data with Phase I, an initial experiment configuration consisting of two far detector modules and a minimal suite of near detector components, with a 1.2 MW proton beam. To realize its extensive, world-leading physics potential requires the full scope of DUNE be completed in Phase II. The three Phase II upgrades are all necessary to achieve DUNE's physics goals: (1) addition of far detector modules three and four for a total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary muon spectrometer with a magnetized, high-pressure gaseous argon TPC and calorimeter
A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE
This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical role in the long-baseline oscillation program, ND-GAr will extend the overall physics program of DUNE. The LBNF high-intensity proton beam will provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to discover new particles and search for new interactions and symmetries beyond those predicted in the Standard Model
Snowmass Neutrino Frontier: DUNE Physics Summary
The Deep Underground Neutrino Experiment (DUNE) is a next-generation
long-baseline neutrino oscillation experiment with a primary physics goal of
observing neutrino and antineutrino oscillation patterns to precisely measure
the parameters governing long-baseline neutrino oscillation in a single
experiment, and to test the three-flavor paradigm. DUNE's design has been
developed by a large, international collaboration of scientists and engineers
to have unique capability to measure neutrino oscillation as a function of
energy in a broadband beam, to resolve degeneracy among oscillation parameters,
and to control systematic uncertainty using the exquisite imaging capability of
massive LArTPC far detector modules and an argon-based near detector. DUNE's
neutrino oscillation measurements will unambiguously resolve the neutrino mass
ordering and provide the sensitivity to discover CP violation in neutrinos for
a wide range of possible values of . DUNE is also uniquely
sensitive to electron neutrinos from a galactic supernova burst, and to a broad
range of physics beyond the Standard Model (BSM), including nucleon decays.
DUNE is anticipated to begin collecting physics data with Phase I, an initial
experiment configuration consisting of two far detector modules and a minimal
suite of near detector components, with a 1.2 MW proton beam. To realize its
extensive, world-leading physics potential requires the full scope of DUNE be
completed in Phase II. The three Phase II upgrades are all necessary to achieve
DUNE's physics goals: (1) addition of far detector modules three and four for a
total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power
from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary
muon spectrometer with a magnetized, high-pressure gaseous argon TPC and
calorimeter.Comment: Contribution to Snowmass 202
- âŠ