26 research outputs found
Magnetic resonance thermometry for hyperthermia in the oropharynx region
Magnetic resonance thermometry (MRT) can measure in-vivo 3D-temperature changes in real-time and noninvasively. However, for the oropharynx region and the entire head and neck, motion potentially introduces large artifacts. Considering long treatment times of 60–90 min, this study aims to evaluate whether MRT around the oropharynx is clinically feasible for hyperthermia treatments and quantify the effects of breathing and swallowing on MRT performance. A 3D-ME-FGRE sequence was used in a phantom cooling down and around the oropharynx of five volunteers over ∼75 min. The imaging protocol consisted of imaging with acceleration (ARC = 2), number of image averages (NEX = 1,2 and 3). For volunteers, the acquisitions included a breath-hold scan and scans with deliberate swallowing. MRT performance was quantified in neck muscle, spinal cord and masseter muscle, using mean average error (MAE), mean error (ME) and spatial standard deviation (SD). In phantom, an increase in NEX leads to a significant decrease in SD, but MAE and ME were unchanged. No significant difference was found in volunteers between the different scans. There was a significant difference between the regions evaluated: neck muscle had the best MAE (=1.96 °C) and SD (=0.82 °C), followed by spinal cord (MAE = 3.17 °C, SD = 0.92 °C) and masseter muscle (MAE = 4.53 °C, SD = 1.16 °C). Concerning the ME, spinal cord did best, then neck muscle and masseter muscle, with values of −0.64 °C, 1.15 °C and −3.05 °C respectively. Breathing, swallowing, and different ways of imaging (acceleration and NEX) do not significantly influence the MRT performance in the oropharynx region. The ROI selected however, leads to significant differences.</p
Eye Size and Shape in Relation to Refractive Error in Children:A Magnetic Resonance Imaging Study
Purpose: The purpose of this study was to determine the association between eye shape and volume measured with magnetic resonance imaging (MRI) and optical biometry and with spherical equivalent (SE) in children. Methods: For this study, there were 3637 10-year-old children from a population-based birth-cohort study that underwent optical biometry (IOL-master 500) and T2-weighted MRI scanning (height, width, and volume). Cycloplegic refractive error was determined by automated refraction. The MRI images of the eyes were segmented using an automated algorithm combining atlas registration with voxel classification. Associations among optical biometry, anthropometry, MRI measurements, and RE were tested using Pearson correlation. Differences between refractive error groups were tested using ANOVA. Results: The mean volume of the posterior segment was 6350 (±680) mm3. Myopic eyes (SE ≤ -0.5 diopters [D]) had 470 mm3 (P < 0.001) and 970 mm3 (P < 0.001) larger posterior segment volume than emmetropic and hyperopic eyes (SE ≥ +2.0D), respectively. The majority of eyes (77.1%) had an oblate shape, but 47.4% of myopic eyes had a prolate shape versus 3.9% of hyperopic eyes. The correlation between SE and MRI-derived posterior segment length (r -0.51, P < 0.001) was stronger than the correlation with height (r -0.30, P < 0.001) or width of the eye (r -0.10, P < 0.001). Conclusions: In this study, eye shape at 10 years of age was predominantly oblate, even in eyes with myopia. Of all MRI measurements, posterior segment length was most prominently associated with SE. Whether eye shape predicts future myopia development or progression should be investigated in longitudinal studies.</p
Eye Size and Shape in Relation to Refractive Error in Children:A Magnetic Resonance Imaging Study
Purpose: The purpose of this study was to determine the association between eye shape and volume measured with magnetic resonance imaging (MRI) and optical biometry and with spherical equivalent (SE) in children. Methods: For this study, there were 3637 10-year-old children from a population-based birth-cohort study that underwent optical biometry (IOL-master 500) and T2-weighted MRI scanning (height, width, and volume). Cycloplegic refractive error was determined by automated refraction. The MRI images of the eyes were segmented using an automated algorithm combining atlas registration with voxel classification. Associations among optical biometry, anthropometry, MRI measurements, and RE were tested using Pearson correlation. Differences between refractive error groups were tested using ANOVA. Results: The mean volume of the posterior segment was 6350 (±680) mm3. Myopic eyes (SE ≤ -0.5 diopters [D]) had 470 mm3 (P < 0.001) and 970 mm3 (P < 0.001) larger posterior segment volume than emmetropic and hyperopic eyes (SE ≥ +2.0D), respectively. The majority of eyes (77.1%) had an oblate shape, but 47.4% of myopic eyes had a prolate shape versus 3.9% of hyperopic eyes. The correlation between SE and MRI-derived posterior segment length (r -0.51, P < 0.001) was stronger than the correlation with height (r -0.30, P < 0.001) or width of the eye (r -0.10, P < 0.001). Conclusions: In this study, eye shape at 10 years of age was predominantly oblate, even in eyes with myopia. Of all MRI measurements, posterior segment length was most prominently associated with SE. Whether eye shape predicts future myopia development or progression should be investigated in longitudinal studies.</p
Relating pre-treatment non-Gaussian intravoxel incoherent motion diffusion-weighted imaging to human papillomavirus status and response in oropharyngeal carcinoma
Background and purpose:Diffusion-weighted imaging (DWI) is a promising technique for response assessment in head-and-neck cancer. Recently, we optimized Non-Gaussian Intravoxel Incoherent Motion Imaging (NG-IVIM), an extension of the conventional apparent diffusion coefficient (ADC) model, for the head and neck. In the current study, we describe the first application in a group of patients with human papillomavirus (HPV)-positive and HPV-negative oropharyngeal squamous cell carcinoma. The aim of this study was to relate ADC and NG-IVIM DWI parameters to HPV status and clinical treatment response. Materials and methods: Thirty-six patients (18 HPV-positive, 18 HPV-negative) were prospectively included. Presence of progressive disease was scored within one year. The mean pre-treatment ADC and NG-IVIM parameters in the gross tumor volume were compared between HPV-positive and HPV-negative patients. In HPV-negative patients, ADC and NG-IVIM parameters were compared between patients with and without progressive disease.Results: ADC, the NG-IVIM diffusion coefficient D, and perfusion fraction f were significantly higher, while pseudo-diffusion coefficient D* and kurtosis K were significantly lower in the HPV-negative compared to HPV-positive patients. In the HPV-negative group, a significantly lower D was found for patients with progressive disease compared to complete responders. No relation with ADC was observed. Conclusion: The results of our single-center study suggest that ADC is related to HPV status, but not an independent response predictor. The NG-IVIM parameter D, however, was independently associated to response in the HPV-negative group. Noteworthy in the opposite direction as previously thought based on ADC.</p
White matter changes measured by multi-component MR Fingerprinting in multiple sclerosis
T2-hyperintense lesions are the key imaging marker of multiple sclerosis (MS). Previous studies have shown that the white matter surrounding such lesions is often also affected by MS. Our aim was to develop a new method to visualize and quantify the extent of white matter tissue changes in MS based on relaxometry properties. We applied a fast, multi-parametric quantitative MRI approach and used a multi-component MR Fingerprinting (MC-MRF) analysis. We assessed the differences in the MRF component representing prolongedrelaxation time between patients with MS and controls and studied the relation between this component's volume and structural white matter damage identified on FLAIR MRI scans in patients with MS. A total of 48 MS patients at two different sites and 12 healthy controls were scanned with FLAIR and MRF-EPI MRI scans. MRF scans were analyzed with a joint-sparsity multi-component analysis to obtain magnetization fraction maps of different components, representing tissues such as myelin water, white matter, gray matter and cerebrospinal fluid. In the MS patients, an additional component was identified with increased transverse relaxation times compared to the white matter, likely representing changes in free water content. Patients with MS had a higher volume of the long- component in the white matter of the brain compared to healthy controls (B (95%-CI) = 0.004 (0.0006–0.008), p = 0.02). Furthermore, this MRF component had a moderate correlation (correlation coefficient R 0.47) with visible structural white matter changes on the FLAIR scans. Also, the component was found to be more extensive compared to structural white matter changes in 73% of MS patients. In conclusion, our MRF acquisition and analysis captured white matter tissue changes in MS patients compared to controls. In patients these tissue changes were more extensive compared to visually detectable white matter changes on FLAIR scans. Our method provides a novel way to quantify the extent of white matter changes in MS patients, which is underestimated using only conventional clinical MRI scans.</p
Super-resolution reconstruction using cross-scale self-similarity in multi-slice MRI
In MRI, the relatively thick slices of multi-slice acquisitions often hamper visualization and analysis of the underlying anatomy. A group of post-processing techniques referred to as super-resolution reconstruction (SRR) have been developed to address this issue. In this study, we present a novel approach to SRR in MRI, which exploits the high-resolution content usually available in the 2D slices of MRI slice stacks to reconstruct isotropic high-resolution 3D images. Relying on the assumption of local self-similarity of anatomical structures, the method can be applied both to a single slice stack and to the combination of multiple slice stacks that differ in the orientation of their field of view. We evaluate the method quantitatively on synthetic brain MRI and qualitatively on MRI of the lungs. The results show that the method outperforms state-of-the-art MRI super-resolution methods
Time efficiency analysis for undersampled quantitative MRI acquisitions
To realize Quantitative MRI (QMRI) with clinically acceptable scan time, acceleration factors achieved by conventional parallel imaging techniques are often inadequate. Further acceleration is possible using model-based reconstruction. We propose a theoretical metric called TEUSQA: Time Efficiency for UnderSampled QMRI Acquisitions to inform sequence design and sample pattern optimisation. TEUSQA is designed for a particular class of reconstruction techniques that directly estimate tissue parameters, possibly using prior information to regularize the estimation. TEUSQA can be used to evaluate undersampling patterns for multi-contrast QMRI sequences targeting any tissue parameter. To verify the time efficiency predicted by TEUSQA, we performed Monte Carlo simulations and an accelerated parameter mapping with two sequences (Inversion prepared fast spin echo for T1 and T2 mapping and 3D GRASE for T2 and B0 inhomogeneity mapping). Using TEUSQA, we assessed several ways to generate undersampling patterns in silico, providing insight into the relation between sample distribution and time efficiency for different acceleration factors. The time efficiency predicted by TEUSQA was within 15% of that observed in the Monte Carlo simulations and the prospective acquisition experiment. The assessment of undersampling patterns showed that a class of good patterns could be obtained by low-discrepancy sampling. We believe that TEUSQA offers a valuable instrument for developers of novel QMRI sequences pushing the boundaries of acceleration to achieve clinically feasible protocols. Finally, we applied a time-efficient undersampling pattern selected using TEUSQA for a 32-fold accelerated scan to map T1 & T2 mapping of a healthy volunteer
Systematic review of reconstruction techniques for accelerated quantitative MRI
The complete list of the papers that were selected in the categorization phase of the review "Systematic review of reconstruction techniques for accelerated quantitative MRI", in combination with the properties that describe them.Other grants: SEP BOF; Grant Number FFB210120, Fonds Wetenschappelijk Onderzoek; Grant Number G084217
Rank-2 model-order selection in diffusion tensor MRI: Infromation complexity based on the total Kullback-Leibler divergence
Diffusion-weighted MRI (DW-MRI) can assess the integrity of white matter (WM) structures in the human brain. Multi-compartment analysis of DW-MRI requires an estimate of the number of compartments to permit unbiased estimation of the diffusion shape in a single fibers as well as crossing fascicles. We propose a new, rotation-invariant measure to assess the suitability of a model by a measure for information complexity (ICOMP) based on the total Kullback-Leibler divergence (TKLD). ICOMP-TKLD is evaluated on simulated data and on data from the Human Connectome Project. Compared to the state-of-the-art, ICOMP-TKLD is the only method that yields reliable model-order selection in both homogeneous and heterogeneous WM regions. Therefore, ICOM-TKLD may open the way for structure-adaptive estimation of diffusion properties of the entire brain