    Absorption Wavebands for Discriminating Oxidation Time of Engine Oil as Detected by FT-IR Spectroscopy

    Get PDF
    Fourier Transform-Infrared (FT-IR) spectroscopy was used to analyze gasoline engine oil (SAE 5W20) samples that were exposed to seven different oxidation times (0 h, 24 h, 48 h, 72 h, 96 h, 120 h, and 144 h) to determine the best wavenumbers and wavenumber ranges for the discrimination of the oxidation times. The thermal oxidation process generated oil samples with varying total base number (TBN) levels. Each wavenumber (400–3900 cm1) and wavenumber ranges identified from the literature and this study were statistically analyzed to determine which wavenumbers and wavenumber ranges could discriminate among all oxidation times. Linear regression was used with the best wavenumbers and wavenumber ranges to predict oxidation time

    Brown adipose tissue and regulation of human body weight

    Get PDF
    Background: Approximately 30% of the global population is affected by obesity. Traditional non-surgical measures for weight loss have limited efficacy and tolerability. Therefore, there is a need for novel, effective therapies. Brown adipose tissue (BAT) has been implicated in physiological energy expenditure, indicating that it could be targeted to achieve weight loss in humans. The use of 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography—computed tomography—(PET-CT) imaging has enabled the discovery of functionally active BAT in the supraclavicular, subclavian, and thoracic spine regions of human adults. This review aims to discuss the reasons behind the renewed interest in BAT, assess whether it is metabolically important in humans, and evaluate its feasibility as a therapeutic target for treating obesity. Sources of material: PubMed Central, Europe PMC, Medline. Findings: In vivo studies have shown that BAT activity is regulated by thyroid hormones and the sympathetic nervous system. Furthermore, BAT uniquely contains uncoupling protein 1 (UCP1) that is largely responsible for non-shivering thermogenesis. Cold exposure can increase BAT recruitment through the browning of white adipose tissue (WAT); however, this technique has practical limitations that may preclude its use. Currently available medicines for humans, such as the β3-adrenergic receptor agonist mirabegron or the farnesoid X receptor agonist obeticholic acid, have generated excitement, although adverse effects are a concern. Capsinoids represent a tolerable alternative, which require further investigation. Conclusions: The use of currently available BAT-activating agents alone is unlikely to achieve significant weight loss in humans. A combination of BAT activation with physical exercise and modern, successful dietary strategies represents a more realistic option

    Importance of Emulsification in Calibrating Infrared Spectroscopes for Analyzing Water Contamination in Used or In-Service Engine Oil

    Get PDF
    Using Fourier transform infrared (FT-IR) spectroscopy we investigated the water content of SAE 15W–40 diesel engine lubricating oil at various levels of contamination to establish instrument calibration standards for measuring water contamination in used or in-service engine oil by the standards of ASTM International. Since some known additives in consumer grade engine oil possess slightly hydrophilic properties, this experiment avoided changing the sample matrix with supplemental additives, such as adding surfactants, to achieve homogeneity of the original sample. The impact of sampling time after contamination on the spectral absorption signature was examined in an attempt to improve the accuracy of water contamination quantification and determine if water-soluble potassium bromide (KBr) windows were suitable for analyzing water in oil emulsions. Analysis of variance (ANOVA) modeling and limit of detection calculations were used to predict the ability to discriminate contamination levels over time. Our results revealed that the amount of water concentration in engine oil could be misinterpreted depending on the timing of the FT-IR measurement of the calibration standard after initial water contamination. Also, KBr windows are not sufficiently etched due to the limited window interaction with water molecules within micelles of emulsions to alter FT-IR spectral signatures

    Observation of a Signal Suppressing Effect in a Binary Mixture of Glycol-Water Contamination in Engine Oil with Fourier-Transform Infrared Spectroscopy

    No full text
    An in-depth experimental study of the matrix effect of antifreeze (ethylene glycol) and water contamination of engine oil through FT-IR spectroscopy. With a comparison of the percent by volume concentration of contaminated fresh 15W-40 engine oil, there appeared to be a noticeable reduction in the O–H stretching signal in the infrared spectrum when ethylene glycol based antifreeze was included as a contaminant. The contaminants of distilled water, a 50/50 mixture of water and commercial ethylene glycol antifreeze, and straight ethylene glycol antifreeze were compared and a signal reduction in the O–H stretch was clearly evident when glycol was present. Doubling the volume of the 50/50 mixture as compared to water alone still resulted in a weaker O–H stretching signal. The possibility that this signal reduction was due to the larger ethylene glycol molecule having fewer O–H bonds in a given sample size was eliminated by comparing samples with the same number of O–H bonds per unit volume. The strong hydrogen bonding between that of water and glycol appeared to reduce the O–H stretching signal, even after comparing the different sample types at concentrations with the same number of O–H bonds per unit volume. Tukey’s highly significant difference was used to show that samples of the 50/50 mixture and straight glycol were not reliably distinguishable from one another when comparing the same number of O–H bonds per unit volume but readily distinguishable from that of water as the lone contaminant

    Observation of a Signal Suppressing Effect in a Binary Mixture of Glycol-Water Contamination in Engine Oil with Fourier-Transform Infrared Spectroscopy

    No full text
    An in-depth experimental study of the matrix effect of antifreeze (ethylene glycol) and water contamination of engine oil through FT-IR spectroscopy. With a comparison of the percent by volume concentration of contaminated fresh 15W-40 engine oil, there appeared to be a noticeable reduction in the O–H stretching signal in the infrared spectrum when ethylene glycol based antifreeze was included as a contaminant. The contaminants of distilled water, a 50/50 mixture of water and commercial ethylene glycol antifreeze, and straight ethylene glycol antifreeze were compared and a signal reduction in the O–H stretch was clearly evident when glycol was present. Doubling the volume of the 50/50 mixture as compared to water alone still resulted in a weaker O–H stretching signal. The possibility that this signal reduction was due to the larger ethylene glycol molecule having fewer O–H bonds in a given sample size was eliminated by comparing samples with the same number of O–H bonds per unit volume. The strong hydrogen bonding between that of water and glycol appeared to reduce the O–H stretching signal, even after comparing the different sample types at concentrations with the same number of O–H bonds per unit volume. Tukey’s highly significant difference was used to show that samples of the 50/50 mixture and straight glycol were not reliably distinguishable from one another when comparing the same number of O–H bonds per unit volume but readily distinguishable from that of water as the lone contaminant

    UV-Visible Spectrophotometer for Distinguishing Oxidation Time of Engine Oil

    No full text
    Samples of gasoline engine oil (SAE 5W20) that had been exposed to various oxidation times were inspected with a UV-Visible (UV-Vis) spectrophotometer to select the best wavelengths and wavelength ranges for distinguishing oxidation times. Engine oil samples were subjected to different thermal oxidation periods of 0, 24, 48, 72, 96, 120, and 144 hours, resulting in a range of total base number (TBN) levels. Each wavelength (190.5 – 849.5 nm) and selected wavelength ranges were evaluated to determine the wavelength or wavelength ranges that could best distinguish among all oxidation times. The best wavelengths and wavelength ranges were analyzed with linear regression to determine the best wavelength or range to predict oxidation time