7 research outputs found

    Normothermic machine perfusion of ischaemically damaged porcine kidneys with autologous, allogeneic porcine and human red blood cells

    Get PDF
    In porcine kidney auto-transplant models, red blood cells (RBCs) are required for ex-vivo normothermic machine perfusion (NMP). As large quantities of RBCs are needed for NMP, utilising autologous RBCs would imply lethal exsanguination of the pig that is donor and recipient-to-be in the same experiment. The purpose of this study was to determine if an isolated porcine kidney can also be perfused with allogeneic porcine or human RBCs instead. Porcine kidneys, autologous and allogeneic blood were obtained from a local slaughterhouse. Human RBCs (O-pos), were provided by our transfusion laboratory. Warm ischaemia time was standardised at 20 minutes and subsequent hypothermic machine perfusion lasted 1.5–2.5 hours. Next, kidneys underwent NMP at 37°C during 7 hours with Williams’ Medium E and washed, leukocyte depleted RBCs of either autologous, allogeneic, or human origin (n = 5 per group). During perfusion all kidneys were functional and produced urine. No macroscopic adverse reactions were observed. Creatinine clearance during NMP was significantly higher in the human RBC group in comparison with the allogeneic group (P = 0.049) but not compared to the autologous group. The concentration of albumin in the urine was significantly higher in the human RBC group (P <0.001) compared to the autologous and allogeneic RBC group. Injury marker aspartate aminotransferase was significantly higher in the human RBC group in comparison with the allogeneic group (P = 0.040) but not in comparison with the autologous group. Renal histology revealed glomerular and tubular damage in all groups. Signs of pathological hyperfiltration and microvascular injury were only observed in the human RBC group. In conclusion, perfusion of porcine kidneys with RBCs of different origin proved technically feasible. However, laboratory analysis and histology revealed more damage in the human RBC group compared to the other two groups. These results indicate that the use of allogeneic RBCs is preferable to human RBCs in a situation where autologous RBCs cannot be used for NMP

    Prolonged ex-vivo normothermic kidney perfusion:The impact of perfusate composition

    Get PDF
    Normothermic machine perfusion (NMP) of donor kidneys provides the opportunity for improved graft preservation and objective pre-transplant ex-vivo organ assessment. Currently, a multitude of perfusion solutions exist for renal NMP. This study aimed to evaluate four different perfusion solutions side-by-side and determine the influence of different perfusate compositions on measured renal perfusion parameters. Porcine kidneys and blood were obtained from a slaughterhouse. Kidneys underwent NMP at 37°C for 7 hours, with 4 different perfusion solutions (n = 5 per group). Group 1 consisted of red blood cells (RBCs) and a perfusion solution based on Williams' Medium E. Group 2 consisted of RBCs, albumin and a balanced electrolyte composition. Group 3 contained RBCs and a medium based on a British clinical NMP solution. Group 4 contained RBCs and a medium used in 24-hour perfusion experiments. NMP flow patterns for solutions 1 and 2 were similar, solutions 3 and 4 showed lower but more stable flow rates. Thiobarbituric acid reactive substances were significantly higher in solution 1 and 4 compared to the other groups. Levels of injury marker N-acetyl-β-D glucosaminidase were significantly lower in solution 2 in comparison with solution 3 and 4. This study illustrates that the perfusate composition during NMP significantly impacts the measured perfusion and injury parameters and thus affects the interpretation of potential viability markers. Further research is required to investigate the individual influences of principal perfusate components to determine the most optimal conditions during NMP and eventually develop universal organ assessment criteria

    Renal Normothermic Machine Perfusion:The Road Toward Clinical Implementation of a Promising Pretransplant Organ Assessment Tool

    Get PDF
    The increased utilization of high-risk renal grafts for transplantation requires optimization of pretransplant organ assessment strategies. Current decision-making methods to accept an organ for transplantation lack overall predictive power and always contain an element of subjectivity. Normothermic machine perfusion (NMP) creates near-physiological conditions, which might facilitate a more objective assessment of organ quality prior to transplantation. NMP is rapidly gaining popularity, with various transplant centers developing their own NMP protocols and renal viability criteria. However, to date, no validated sets of on-pump viability markers exist nor are there unified NMP protocols. This review provides a critical overview of the fundamentals of current renal NMP protocols and proposes a framework to approach further development of ex vivo organ evaluation. We also comment on the potential logistical implications of routine clinical use of NMP, which is a more complex procedure compared to static cold storage or even hypothermic machine perfusion. Supplemental Visual Abstract; http://links.lww.com/TP/C232

    Improved Normothermic Machine Perfusion After Short Oxygenated Hypothermic Machine Perfusion of Ischemically Injured Porcine Kidneys

    Get PDF
    Background: In an era where global kidney shortage has pushed the field of transplantation towards using more marginal donors, modified kidney preservation techniques are currently being reviewed. Some techniques require further optimization before implementation in full scale transplantation studies. Using a porcine donation after circulatory death kidney model, we investigated whether initial kidney hemodynamics improved during normothermic machine perfusion if this was preceded by a short period of oxygenated hypothermic machine perfusion (oxHMP) rather than static cold storage (SCS). Methods: Kidneys subjected to 75 minutes of warm ischemia were randomly assigned to either SCS (n = 4) or SCS + oxHMP (n = 4), with a total cold storage time of 240 minutes. Cold preservation was followed by 120 minutes of normothermic machine perfusion with continuous measurement of hemodynamic parameters and renal function. Results: oxHMP preserved kidneys maintained significantly lower renal resistance throughout the normothermic machine perfusion period compared to SCS kidneys (P < 0.001), reaching lowest levels at 60 minutes with means of 0.71 ± 0.35 mm Hg/mL/min/100 g (SCS) and 0.45 ± 0.15 mm Hg/mL/min/100 g (oxHMP). Accordingly, the oxHMP group had a higher mean renal blood flow versus SCS kidneys (P < 0.001). oxHMP kidneys had higher oxygen consumption during normothermic machine perfusion compared to SCS preserved kidneys (P < 0.001). Creatinine clearance remained similar between groups (P = 0.665). Conclusions: Preceding oxHMP significantly improved initial normothermic machine perfusion hemodynamics and increased total oxygen consumption. With the long period of warm ischemia, immediate kidney function was not observed, reflected by the findings of low creatinine clearance in both groups

    Magnetic resonance imaging assessment of renal flow distribution patterns during ex vivo normothermic machine perfusion in porcine and human kidneys

    Get PDF
    Acceptance criteria of deceased donor organs have gradually been extended toward suboptimal quality, posing an urgent need for more objective pre-transplant organ assessment. Ex vivo normothermic machine perfusion (NMP) combined with magnetic resonance imaging (MRI) could assist clinicians in deciding whether a donor kidney is suitable for transplantation. Aim of this study was to characterize the regional distribution of perfusate flow during NMP, to better understand how ex vivo kidney assessment protocols should eventually be designed. Nine porcine and 4 human discarded kidneys underwent 3 h of NMP in an MRI-compatible perfusion setup. Arterial spin labeling scans were performed every 15 min, resulting in perfusion-weighted images that visualize intrarenal flow distribution. At the start of NMP, all kidneys were mainly centrally perfused and it took time for the outer cortex to reach its physiological dominant perfusion state. Calculated corticomedullary ratios based on the perfusion maps reached a physiological range comparable to in vivo observations, but only after 1 to 2 h after the start of NMP. Before that, the functionally important renal cortex appeared severely underperfused. Our findings suggest that early functional NMP quality assessment markers may not reflect actual physiology and should therefore be interpreted with caution

    Treating Ischemically Damaged Porcine Kidneys with Human Bone Marrow- and Adipose Tissue-Derived Mesenchymal Stromal Cells During Ex Vivo Normothermic Machine Perfusion

    No full text
    Pretransplant normothermic machine perfusion (NMP) of donor kidneys offers the unique opportunity to perform active interventions to an isolated renal graft before transplantation. There is increasing evidence that mesenchymal stromal cells (MSCs) could have a paracrine/endocrine regenerative effect on ischemia-reperfusion injury. The purpose of this study was to determine which cytokines are secreted by MSCs during NMP of a porcine kidney. Viable porcine kidneys and autologous whole blood were obtained from a slaughterhouse. Warm ischemia time was standardized at 20 min and subsequent hypothermic machine perfusion was performed during 2-3 h. Thereafter, kidneys were machine perfused at 37°C during 7 h. After 1 h of NMP, 0, 107 cultured human adipose tissue-derived MSCs, or 107 cultured bone marrow-derived MSCs were added (n = 5 per group). In a fourth experimental group, 7-h NMP was performed with 107 adipose tissue-derived MSCs, without a kidney in the circuit. Kidneys perfused with MSCs showed lower lactate dehydrogenase and neutrophil gelatinase-associated lipocalin levels in comparison with the control group. Also, elevated levels of human hepatocyte growth factor, interleukin (IL)-6, and IL-8 were found in the perfusate of the groups perfused with MSCs compared to the control groups. This study suggests that MSCs, in contact with an injured kidney during NMP, could lead to lower levels of injury markers and induce the release of immunomodulatory cytokines

    Magnetic resonance imaging during warm ex vivo kidney perfusion

    Get PDF
    BACKGROUND: The shortage of donor organs for transplantation remains a worldwide problem. The utilization of suboptimal deceased donors enlarges the pool of potential organs, yet consequently, clinicians face the difficult decision of whether these sub-optimal organs are of sufficient quality for transplantation. Novel technologies could play a pivotal role in making pre-transplant organ assessment more objective and reliable. METHODS: Ex vivo normothermic machine perfusion (NMP) at temperatures around 35-37°C allows organ quality assessment in a near-physiological environment. Advanced magnetic resonance imaging (MRI) techniques convey unique information about an organ's structural and functional integrity. The concept of applying magnetic resonance imaging during renal normothermic machine perfusion is novel in both renal and radiological research and we have developed the first MRI-compatible NMP setup for human-sized kidneys. RESULTS: We were able to obtain a detailed and real-time view of ongoing processes inside renal grafts during ex vivo perfusion. This new technique can visualize structural abnormalities, quantify regional flow distribution, renal metabolism, and local oxygen availability, and track the distribution of ex vivo administered cellular therapy. CONCLUSION: This platform allows for advanced pre-transplant organ assessment, provides a new realistic tool for studies into renal physiology and metabolism, and may facilitate therapeutic tracing of pharmacological and cellular interventions to an isolated kidney
    corecore