163 research outputs found
Status of research into lightning effects on aircraft
Developments in aircraft lightning protection since 1938 are reviewed. Potential lightning problems resulting from present trends toward the use of electronic controls and composite structures are discussed, along with presently available lightning test procedures for problem assessment. The validity of some procedures is being questioned because of pessimistic results and design implications. An in-flight measurement program is needed to provide statistics on lightning severity at flight altitudes and to enable more realistic tests, and operators are urged to supply researchers with more details on electronic components damaged by lightning strikes. A need for review of certain aspects of fuel system vulnerability is indicated by several recent accidents, and specific areas for examination are identified. New educational materials and standardization activities are also noted
Investigation of severe lightning strike incidents to two USAF F-106A aircraft
The results of the inspection and analysis of two F-106A aircraft that were struck by separate lightning strikes within a few minutes of each other are presented. Each aircraft sustained severe lightning strikes to the pitot booms, resulting in extensive damage to the pitot heater power harness, number 8 ground wire, and lightning suppressors, but there was no damage to either aircraft's electrical or avionic systems. A simulated lightning current of 226 kA and 3.8 million A(2)*S was required to reproduce the damage to the ground wires in the radomes. Photographs and detailed assessments of the damage are included
Lightning protection guidelines and test data for adhesively bonded aircraft structures
The highly competitive marketplace and increasing cost of energy has motivated manufacturers of general aviation aircraft to utilize composite materials and metal-to-metal bonding in place of conventional fasteners and rivets to reduce weight, obtain smoother outside surfaces and reduce drag. The purpose of this program is protection of these new structures from hazardous lightning effects. The program began with a survey of advance-technology materials and fabrication methods under consideration for future designs. Sub-element specimens were subjected to simulated lightning voltages and currents. Measurements of bond line voltages, electrical sparking, and mechanical strength degradation were made to comprise a data base of electrical properties for new technology materials and basic structural configurations. The second hase of the program involved tests on full scale wing structures which contained integral fuel tanks and which were representative of examples of new technology structures and fuel systems. The purpose of these tests was to provide a comparison between full scale structural measurements and those obtained from the sub-element specimens
A test and measurement technique for determining possible lightning-induced voltages in aircraft electrical circuits
Transient analyzer consists of four 0.5 microfarads capacitors chargeable by self-contained solid state 50 KV dc power supply operating from standard 110 Vac line voltage. Unit can circulate unidirectional current impulses of up to 500 amperes through aircraft at waveshapes similar to those of natural lightning strokes
Effects of simulated lightning on composite and metallic joints
The effects of simulated lightning strikes and currents on aircraft bonded joints and access/inspection panels were investigated. Both metallic and composite specimens were tested. Tests on metal fuel feed through elbows in graphite/epoxy structures were evaluated. Sparking threshold and residual strength of single lap bonded joints and sparking threshold of access/inspection panels and metal fuel feed through elbows are reported
Preliminary tests of vulnerability of typical aircraft electronics to lightning-induced voltages
Tests made on two pieces of typical aircraft electronics equipment to ascertain their vulnerability to simulated lightning-induced transient voltages representative of those which might occur in flight when the aircraft is struck by lightning were conducted. The test results demonstrated that such equipment can be interfered with or damaged by transient voltages as low as 21 volts peak. Greater voltages can cause failure of semiconductor components within the equipment. The results emphasize a need for establishment of coordinated system susceptibility and component vulnerability criteria to achieve lightning protection of aerospace electrical and electronic systems
Magnetic Phase Diagram of the Ferromagnetically Stacked Triangular XY Antiferromagnet: A Finite-Size Scaling Study
Histogram Monte-Carlo simulation results are presented for the magnetic-field
-- temperature phase diagram of the XY model on a stacked triangular lattice
with antiferromagnetic intraplane and ferromagnetic interplane interactions.
Finite-size scaling results at the various transition boundaries are consistent
with expectations based on symmetry arguments. Although a molecular-field
treatment of the Hamiltonian fails to reproduce the correct structure for the
phase diagram, it is demonstrated that a phenomenological Landau-type
free-energy model contains all the esstential features. These results serve to
complement and extend our earlier work [Phys. Rev. B {\bf 48}, 3840 (1993)].Comment: 5 pages (RevTex 3.0), 6 figures available upon request, CRPS 93-
Improved test methods for determining lightning-induced voltages in aircraft
A lumped parameter transmission line with a surge impedance matching that of the aircraft and its return lines was evaluated as a replacement for earlier current generators. Various test circuit parameters were evaluated using a 1/10 scale relative geometric model. Induced voltage response was evaluated by taking measurements on the NASA-Dryden Digital Fly by Wire F-8 aircraft. Return conductor arrangements as well as other circuit changes were also evaluated, with all induced voltage measurements being made on the same circuit for comparison purposes. The lumped parameter transmission line generates a concave front current wave with the peak di/dt near the peak of the current wave which is more representative of lightning. However, the induced voltage measurements when scaled by appropriate scale factors (peak current or di/dt) resulting from both techniques yield comparable results
Measurement and analysis of lightning induced voltages in aircraft electrical systems
Lightning induced voltages in aircraft electrical circuit
Analysis and calculation of lightning-induced voltages in aircraft electrical circuits
Techniques to calculate the transfer functions relating lightning-induced voltages in aircraft electrical circuits to aircraft physical characteristics and lightning current parameters are discussed. The analytical work was carried out concurrently with an experimental program of measurements of lightning-induced voltages in the electrical circuits of an F89-J aircraft. A computer program, ETCAL, developed earlier to calculate resistive and inductive transfer functions is refined to account for skin effect, providing results more valid over a wider range of lightning waveshapes than formerly possible. A computer program, WING, is derived to calculate the resistive and inductive transfer functions between a basic aircraft wing and a circuit conductor inside it. Good agreement is obtained between transfer inductances calculated by WING and those reduced from measured data by ETCAL. This computer program shows promise of expansion to permit eventual calculation of potential lightning-induced voltages in electrical circuits of complete aircraft in the design stage
- …