1,636 research outputs found
Band gaps in the relaxed linear micromorphic continuum
In this note we show that the relaxed linear micromorphic model recently
proposed by the authors can be suitably used to describe the presence of
band-gaps in metamaterials with microstructures in which strong contrasts of
the mechanical properties are present (e.g. phononic crystals and lattice
structures). This relaxed micromorphic model only has 6 constitutive parameters
instead of 18 parameters needed in Mindlin- and Eringen-type classical
micromorphic models. We show that the onset of band-gaps is related to a unique
constitutive parameter, the Cosserat couple modulus which starts to
account for band-gaps when reaching a suitable threshold value. The limited
number of parameters of our model, as well as the specific effect of some of
them on wave propagation can be seen as an important step towards indirect
measurement campaigns
Recent Results on Energy Calibration at LEP
The determination of the centre-of-mass energy at the four experiments installed on the CERN Large Electron Positron (LEP) collider is one of the major ingredients in the Standard Model investigations being carried on in the context of the experimental programme. Several depolarising effects at beam energies beyond 60 GeV limit the application of the Resonant Depolarisation (RD) method, which provi des an energy uncertainty of about ±1 MeV at the Z0 resonance. Extrapolation techniques from magnetic field measurements are used to obtain beam energies in the W-pair region, aiming at a total energy error £15 MeV. Consistency checks over a large range of precisely calibrated energies are mandatory to contain systematic errors from extrapolation. Progress obtained in extending the polarisable ener gy range in the 1997 LEP Run and the preliminary extrapolation errors are reported
Observation of radiative spin-polarization at 60.6 GeV
Radiative spin-polarization has been used extensively at LEP to accurately measure the beam energy around the Z resonance. As the LEP physics has moved on to the W boson the calibration based on polarization must be extended towards higher beam energies. This is difficult as the depolarizing effects of spin resonances grow rapidly with beam energy. At LEP it has been possible for the first time to measure transverse beam polarization at 60.6 GeV. To allow a build-up of polarization the tunes and the energy were chosen accurately. A low phase advance optics was used and careful orbit correction was carried out using dynamic beam based alignment data. Harmonic spin matching was applied both in a deterministic and a novel semi- empirical way. (11 refs)
Can We Really Prevent Suicide?
Every year, suicide is among the top 20 leading causes of death globally for all ages. Unfortunately, suicide is difficult to prevent, in large part because the prevalence of risk factors is high among the general population. In this review, clinical and psychological risk factors are examined and methods for suicide prevention are discussed. Prevention strategies found to be effective in suicide prevention
include means restriction, responsible media coverage, and general public education, as well identification methods such as screening, gatekeeper training, and primary care physician education. Although the treatment for preventing suicide is difficult, follow-up that includes pharmacotherapy, psychotherapy, or both may be useful. However, prevention methods cannot be restricted to the individual. Community, social, and policy interventions will also be essentia
Status of the LEP2 Spectrometer Project
The LEP spectrometer has been conceived to provide a determination of the beam energy with a relative accuracy of 10-4 in the LEP2 physics region where insufficient polarisation levels prevent the application of the resonant depolarisation method. The setup consists of a steel bending magnet flanked by a triplet of Beam Position Monitors (BPM) at each side providing a measurement of changes in the bending angle when the beams are accelerated to physics energies. The goal for a 100 ppm relative precision on the beam energy involves a ± 1 micron BPM resolution and the calibration of the dipole bending strength to a 30 ppm accuracy. This paper reports on the results of the commissioning of the Spectrometer during the 1999 LEP Run and on the experience acquired on the behaviour of the several sub-systems with circulating beams
The energy calibration of LEP in the 1993 scan
This report summarizes the procedure for providing the absolute energy calibration of the LEP beams during the energy scan in 1993. The average beam energy around the LEP ring was measured in 25 calibrations with the resonant depolarization technique. The time variation of this average beam energy is well described by a model of the accelerator based on monitored quantities. The absolute calibration of the centre of mass energies of the off-peak points is determined with a precision of 2 parts in 10(5) resulting in a systematic error on the Z-mass of about 1.4 MeV and on the Z-width of about 1.5 MeV
- …
