3 research outputs found

    Prognostic value of implantable defibrillator-computed respiratory disturbance index: The DASAP-HF study

    No full text
    BACKGROUND: Sleep apnea, as measured by polysomnography, is associated with adverse outcomes in heart failure. The DASAP-HF (Diagnosis and Treatment of Sleep Apnea in Patient With Heart Failure) study previously demonstrated that the respiratory disturbance index (RDI) computed by the ApneaScan algorithm (Boston Scientific) accurately identifies severe sleep apnea in implantable cardioverter-defibrillator (ICD) patients.OBJECTIVE: The purpose of the long-term study phase was to assess the incidence of clinical events after 24 months and investigate the association with RDI values.METHODS: Patients with left ventricular ejection fraction 6435% implanted with an ICD were enrolled and followed-up for 24 months. The RDI calculated at 1 month after implantation was used to stratify patients (below or above 30 episodes/h). The endpoints were all-cause death and a combination of all-cause death or cardiovascular hospitalization.RESULTS: Of the 265 enrolled patients, 224 had usable RDI values. Severe sleep apnea (RDI 6530 episodes/h) was diagnosed in 115 patients (51%). These patients were more frequently male (84% vs 72%; P = .030) and had higher creatinine levels. During median follow-up of 25 months, 19 patients (8%) died. Cardiovascular hospitalizations were reported in 19 patients (8%). The risk of all-cause death was higher in patients with RDI 6530 episodes/h (hazard ratio [HR] 3.33; 95% confidence interval [CI] 1.35-8.21; P = .023), as well as the risk of all-cause death or cardiovascular hospitalization (HR 1.94; 95% CI 1.01-3.76; P = .048). At multivariate analysis, independent predictors of death were RDI 6530 episodes/h (HR 4.02; 95% CI 1.16-13.97; P = .029) and creatinine levels (HR 2.36; 95% CI 1.26-4.42; P = .008).CONCLUSION: In heart failure patients implanted with an ICD, higher RDI values are associated with death and cardiovascular hospitalizations. Device-detected severe sleep apnea independently predicts death

    Use and outcomes of subcutaneous implantable cardioverter-defibrillator (ICD) after transvenous ICD extraction: An analysis of current clinical practice and a comparison with transvenous ICD reimplantation

    No full text
    Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) does not require the insertion of any leads into the cardiovascular system. Objective: The aims of the study were to describe current practice and to measure outcomes associated with S-ICD or standard single-chamber transvenous ICD (TV-ICD) use after TV-ICD explantation. Methods: We analyzed all consecutive patients who underwent transvenous extraction of an ICD and subsequent implantation of an S-ICD or a single-chamber TV-ICD at 12 Italian centers from 2011 to 2017. Results: A total of 229 patients were extracted and subsequently reimplanted with an S-ICD (90; 39%) or a single-chamber TV-ICD (139; 61%). S-ICD implantation increased from 9% in 2011 to 85% in 2017 (P <.001). Patients reimplanted with an S-ICD were younger (53 ± 13 years vs 60 ± 18 years; P =.011) and more frequently had undergone extraction owing to infection (73% vs 52%; P <.001). The rates of complications at follow-up were comparable between groups (hazard ratio 0.97; 95% confidence interval 0.49–1.92; P =.940). No lead failures, systemic infections, or system-related deaths occurred in the S-ICD group. In the TV-ICD group, 1 lead fracture occurred and 2 systemic infections were reported, resulting in death in 1 case. In the S-ICD group, the rate of complications was lower when the generator was positioned in a sub- or intermuscular pocket (hazard ratio 0.21; 95% confidence interval 0.05–0.87; P =.048). Conclusion: Our results show an increasing use of S-ICD over the years in patients undergoing TV-ICD explantation. An S-ICD is preferably adopted in young patients, mostly in the case of infection. The complication rate was comparable between groups and decreased when a sub- or intermuscular S-ICD generator position was adopted
    corecore