11 research outputs found
Ability of fabric face mask materials to filter ultrafine particles at coughing velocity.
OBJECTIVE:We examined the ability of fabrics which might be used to create home-made face masks to filter out ultrafine (0.02-0.1 µm) particles at the velocity of adult human coughing. METHODS:Twenty commonly available fabrics and materials were evaluated for their ability to reduce air concentrations of ultrafine particles at coughing face velocities. Further assessment was made on the filtration ability of selected fabrics while damp and of fabric combinations which might be used to construct home-made masks. RESULTS:Single fabric layers blocked a range of ultrafine particles. When fabrics were layered, a higher percentage of ultrafine particles were filtered. The average filtration efficiency of single layer fabrics and of layered combination was found to be 35% and 45%, respectively. Non-woven fusible interfacing, when combined with other fabrics, could add up to 11% additional filtration efficiency. However, fabric and fabric combinations were more difficult to breathe through than N95 masks. CONCLUSIONS:The current coronavirus pandemic has left many communities without access to N95 face masks. Our findings suggest that face masks made from layered common fabric can help filter ultrafine particles and provide some protection for the wearer when commercial face masks are unavailable
Comparing the fit of N95, KN95, surgical, and cloth face masks and assessing the accuracy of fit checking.
INTRODUCTION: The COVID-19 pandemic has made well-fitting face masks a critical piece of protective equipment for healthcare workers and civilians. While the importance of wearing face masks has been acknowledged, there remains a lack of understanding about the role of good fit in rendering protective equipment useful. In addition, supply chain constraints have caused some organizations to abandon traditional quantitative or/and qualitative fit testing, and instead, have implemented subjective fit checking. Our study seeks to quantitatively evaluate the level of fit offered by various types of masks, and most importantly, assess the accuracy of implementing fit checks by comparing fit check results to quantitative fit testing results. METHODS: Seven participants first evaluated N95 and KN95 respirators by performing a fit check. Participants then underwent quantitative fit testing wearing five N95 respirators, a KN95 respirator, a surgical mask, and fabric masks. RESULTS: N95 respirators offered higher degrees of protection than the other categories of masks tested; however, it should be noted that most N95 respirators failed to fit the participants adequately. Fit check responses had poor correlation with quantitative fit factor scores. KN95, surgical, and fabric masks achieved low fit factor scores, with little protective difference recorded between respiratory protection options. In addition, small facial differences were observed to have a significant impact on quantitative fit. CONCLUSION: Fit is critical to the level of protection offered by respirators. For an N95 respirator to provide the promised protection, it must fit the participant. Performing a fit check via NHS self-assessment guidelines was an unreliable way of determining fit
Comparing the fit of N95, KN95, surgical, and cloth face masks and assessing the accuracy of fit checking.
INTRODUCTION: The COVID-19 pandemic has made well-fitting face masks a critical piece of protective equipment for healthcare workers and civilians. While the importance of wearing face masks has been acknowledged, there remains a lack of understanding about the role of good fit in rendering protective equipment useful. In addition, supply chain constraints have caused some organizations to abandon traditional quantitative or/and qualitative fit testing, and instead, have implemented subjective fit checking. Our study seeks to quantitatively evaluate the level of fit offered by various types of masks, and most importantly, assess the accuracy of implementing fit checks by comparing fit check results to quantitative fit testing results. METHODS: Seven participants first evaluated N95 and KN95 respirators by performing a fit check. Participants then underwent quantitative fit testing wearing five N95 respirators, a KN95 respirator, a surgical mask, and fabric masks. RESULTS: N95 respirators offered higher degrees of protection than the other categories of masks tested; however, it should be noted that most N95 respirators failed to fit the participants adequately. Fit check responses had poor correlation with quantitative fit factor scores. KN95, surgical, and fabric masks achieved low fit factor scores, with little protective difference recorded between respiratory protection options. In addition, small facial differences were observed to have a significant impact on quantitative fit. CONCLUSION: Fit is critical to the level of protection offered by respirators. For an N95 respirator to provide the promised protection, it must fit the participant. Performing a fit check via NHS self-assessment guidelines was an unreliable way of determining fit
Face mask fit hacks: Improving the fit of KN95 masks and surgical masks with fit alteration techniques.
INTRODUCTION: During the course of the COVID-19 pandemic, there have been suggestions that various techniques could be employed to improve the fit and, therefore, the effectiveness of face masks. It is well recognized that improving fit tends to improve mask effectiveness, but whether these fit modifiers are reliable remains unexplored. In this study, we assess a range of common "fit hacks" to determine their ability to improve mask performance. METHODS: Between July and September 2020, qualitative fit testing was performed in an indoor living space. We used quantitative fit testing to assess the fit of both surgical masks and KN95 masks, with and without 'fit hacks', on four participants. Seven fit hacks were evaluated to assess impact on fit. Additionally, one participant applied each fit hack multiple times to assess how reliable hacks were when reapplied. A convenience of four participants took part in the study, three females and one male with a head circumference range of 54 to 60 centimetres. RESULTS AND DISCUSSION: The use of pantyhose, tape, and rubber bands were effective for most participants. A pantyhose overlayer was observed to be the most effective hack. High degrees of variation were noted between participants. However, little variation was noted within participants, with hacks generally showing similar benefit each time they were applied on a single participant. An inspection of the fit hacks once applied showed that individual facial features may have a significant impact on fit, especially the nose bridge. CONCLUSIONS: Fit hacks can be used to effectively improve the fit of surgical and KN95 masks, enhancing the protection provided to the wearer. However, many of the most effective hacks are very uncomfortable and unlikely to be tolerated for extended periods of time. The development of effective fit-improvement solutions remains a critical issue in need of further development
High-Resolution Spectral Sleep Analysis Reveals a Novel Association Between Slow Oscillations and Memory Retention in Elderly Adults
Objective: In recognition of the mixed associations between traditionally scored slow wave sleep and memory, we sought to explore the relationships between slow wave sleep, electroencephalographic (EEG) power spectra during sleep and overnight verbal memory retention in older adults.
Design, Setting, Participants, and Measurements: Participants were 101 adults without dementia (52% female, mean age 70.3 years). Delayed verbal memory was first tested in the evening prior to overnight polysomnography (PSG). The following morning, subjects were asked to recall as many items as possible from the same List (overnight memory retention; OMR). Partial correlation analyses examined the associations of delayed verbal memory and OMR with slow wave sleep (SWS) and two physiologic EEG slow wave activity (SWA) power spectral bands (0.5–1 Hz slow oscillations vs. 1–4 Hz delta activity).
Results: In subjects displaying SWS, SWS was associated with enhanced delayed verbal memory, but not with OMR. Interestingly, among participants that did not show SWS, OMR was significantly associated with a higher slow oscillation relative power, during NREM sleep in the first ultradian cycle, with medium effect size.
Conclusions: These findings suggest a complex relationship between SWS and memory and illustrate that even in the absence of scorable SWS, older adults demonstrate substantial slow wave activity. Further, these slow oscillations (0.5–1 Hz), in the first ultradian cycle, are positively associated with OMR, but only in those without SWS. Our findings raise the possibility that precise features of slow wave activity play key roles in maintaining memory function in healthy aging. Further, our results underscore that conventional methods of sleep evaluation may not be sufficiently sensitive to detect associations between SWA and memory in older adults
Neurocognitive markers of passive suicidal ideation in late-life depression
Objectives: (1) To delineate whether cognitive flexibility and inhibitory ability are neurocognitive markers of passive suicidal ideation (PSI), an early stage of suicide risk in depression and (2) to determine whether PSI is associated with volumetric differences in regions of the prefrontal cortex (PFC) in middle-aged and older adults with depression.
Design: Cross-sectional study.
Setting: University medical school.
Participants: Forty community-dwelling middle-aged and older adults with depression from a larger study of depression and anxiety (NIMH R01 MH091342-05 PI: O\u27Hara).
Measurements: Psychiatric measures were assessed for the presence of a DSM-5 depressive disorder and PSI. A neurocognitive battery assessed cognitive flexibility, inhibitory ability, as well as other neurocognitive domains.
Results: The PSI group (n = 18) performed significantly worse on cognitive flexibility and inhibitory ability, but not on other neurocognitive tasks, compared to the group without PSI (n = 22). The group with PSI had larger left mid-frontal gyri (MFG) than the no-PSI group. There was no association between cognitive flexibility/inhibitory ability and left MFG volume.
Conclusions: Findings implicate a neurocognitive signature of PSI: poorer cognitive flexibility and poor inhibitory ability not better accounted for by other domains of cognitive dysfunction and not associated with volumetric differences in the left MFG. This suggests that there are two specific but independent risk factors of PSI in middle- and older-aged adults
Recommended from our members
Ability of fabric face mask materials to filter ultrafine particles at coughing velocity.
OBJECTIVE:We examined the ability of fabrics which might be used to create home-made face masks to filter out ultrafine (0.02-0.1 µm) particles at the velocity of adult human coughing. METHODS:Twenty commonly available fabrics and materials were evaluated for their ability to reduce air concentrations of ultrafine particles at coughing face velocities. Further assessment was made on the filtration ability of selected fabrics while damp and of fabric combinations which might be used to construct home-made masks. RESULTS:Single fabric layers blocked a range of ultrafine particles. When fabrics were layered, a higher percentage of ultrafine particles were filtered. The average filtration efficiency of single layer fabrics and of layered combination was found to be 35% and 45%, respectively. Non-woven fusible interfacing, when combined with other fabrics, could add up to 11% additional filtration efficiency. However, fabric and fabric combinations were more difficult to breathe through than N95 masks. CONCLUSIONS:The current coronavirus pandemic has left many communities without access to N95 face masks. Our findings suggest that face masks made from layered common fabric can help filter ultrafine particles and provide some protection for the wearer when commercial face masks are unavailable
Recommended from our members
Research data supporting "Experimental Measurement of the Size of Gaps Required to Compromise Fit of an N95 Respirator"
The effectiveness of N95 masks is heavily dependent on the quality of mask fit, with poor fit rendering such masks inadequate to protect the wearer. However, there have been limited efforts to discover the size of the gaps in the seal required to compromise mask performance, with prior studies estimating this size based on in vitro models. In this study, we measure the size of gap necessary to compromise the OSHA protection requirements of N95 masks. The data were generated via quantitative fit testing on two individuals. Quantitative fit testing was performed with a TSI Portacount Pro Respirator Fit Tester model 8038+, capable of assessing masks with less than 99% filtration efficiency. The device measures particles with a minimum size of 0.02 micrometers at a sampling flow rate of 350 cm^3/min
Experimental Measurement of the Size of Gaps Required to Compromise Fit of an N95 Respirator.
OBJECTIVE: The effectiveness of filtering facepiece respirators such as N95 respirators is heavily dependent on the fit. However, there have been limited efforts to discover the size of the gaps in the seal required to compromise filtering facepiece respirator performance, with prior studies estimating this size based on in vitro models. In this study, we measure the size of leak necessary to compromise the fit of N95 respirators. METHODS: Two methods were used to create a gap of specific dimensions. A set of 3D-printed resin spacers and hollow steel rods were used to generate gaps in N95 respirators while worn on 2 participants. Occupational Safety and Health Administration (OSHA) quantitative fit testing methods were used to quantify mask performance with gaps between 0.4 and 2.9-mm diameters. RESULTS: Gap size was regressed against fit factor, showing that overall, the minimum gap size to compromise N95 performance was between 1.5 mm2 and 3 mm2. CONCLUSIONS: These findings suggest the fit of a N95 respirator is compromised by gaps that may be difficult to visually detect. The study also adds to the body of evidence supporting the routine use of quantitative fit testing to ensure that masks are well-fitting
Subjective but not objective sleep is associated with subsyndromal anxiety and depression in community-dwelling older adults
To examine the relationship between subclinical anxiety and depressive symptoms and objective sleep architecture measures and subjective sleep reports in older adults.Community-dwelling older adults (N = 167) self-rated their current severity of anxiety symptoms, depressive symptoms, daytime sleepiness, and global sleep quality. Participants received overnight ambulatory polysomnography to assess sleep architecture. Multivariate linear regression models examined associations between anxiety and depressive symptoms and objective and subjective sleep measures.Significant findings emerged for subjective sleep, with higher depression and anxiety scores associated with worse global sleep quality and greater anxiety scores associated with greater daytime sleepiness. No significant associations were observed between subclinical levels of anxiety or depressive symptoms with sleep architecture.Subclinical levels of late-life anxiety and depression have distinct associations with subjective sleep disturbance. Findings implicate subjective measures of sleep quality and daytime sleepiness as stronger trait markers for subthreshold psychiatric symptoms than objective sleep biomarkers