134 research outputs found
Recommended from our members
Design of the 26.7 MHz rf cavity for RHIC
The accelerating system for RHIC operates at 26.7 MHz (h = 342) and must capture the injected beam, accelerate it to top energy, and shorten the bunches prior to rebucketing into the storage (h = 2508) system. These different functions set the design parameters of the cavity. The frequency of 26.7 MHz has been chosen in order to provide large enough buckets to capture the injected beam from the AGS and a large linear region for debunching during a bunch rotation at top energy. Provision of the large linear region also dictates the voltage requirement of 400 kV per cavity. The cavity must be tuned {approximately}90 kHz to compensate for the change in speed of the gold beam
Recommended from our members
RHIC 28 MHz Accelerating Cavity System.
The 28 MHz accelerating system consists of a quarter wave cavity driven by an inductively coupled 100kW tetrode amplifer and 1kW solid state driver amplifer. 40dB of rf feedback closed around the cavity and amplifers reduces small perturbations within the loop by a factor of 100, and reduces the time required to shift the phase at transition by a factor of 10, limited by the saturation of the drive chain. The cavity is tuned over a 200kHz range by a mechanical tuner which varies the gap capacitance. Broadband HOM damping is provided by two orthogonal loop coupled high pass filters. Design parameters and commissioning results are presented
Region of Interest focused MRI to Synthetic CT Translation using Regression and Classification Multi-task Network
In this work, we present a method for synthetic CT (sCT) generation from zero-echo-time (ZTE) MRI aimed at structural and quantitative accuracies of the image, with a particular focus on the accurate bone density value prediction. We propose a loss function that favors a spatially sparse region in the image. We harness the ability of a multi-task network to produce correlated outputs as a framework to enable localisation of region of interest (RoI) via classification, emphasize regression of values within RoI and still retain the overall accuracy via global regression. The network is optimized by a composite loss function that combines a dedicated loss from each task. We demonstrate how the multi-task network with RoI focused loss offers an advantage over other configurations of the network to achieve higher accuracy of performance. This is relevant to sCT where failure to accurately estimate high Hounsfield Unit values of bone could lead to impaired accuracy in clinical applications. We compare the dose calculation maps from the proposed sCT and the real CT in a radiation therapy treatment planning setup
CERN PS laser ion source development
CERN, together with ITEP and TRINITI (Russia), is developing a CO2 laser ion source. The key design parameters are: 1.4 1010 ions of Pb25+ in a pulse of 5.5 ms, with a 4-rms emittance of 0.2 10-6 rad m, working at a repetition rate of 1 Hz. This device is considered as one candidate source for LHC heavy ion operation. The status of the laser development, the experimental set-up of the source consisting of the target area and its illumination, the plasma expansion area and extraction, beam transport and ion pre-acceleration by an RFQ, will be given
ASASSN-15lu is a Type Ia Supernova
We report spectroscopic classification of ASASSN-15lu (ATel #7698) in SDSS J132112.88+401556.7 (z=0.035037, via NED) through inspection of an optical spectrum (range 370-680 nm, resolution 0.8 nm), obtained with the 2.3-m Bok telescope (+ Boller & Chivens spectrograph) at Kitt Peak on 2015 June 24.2 UT
- …