1,709 research outputs found

    Prognostic indication of power cable degradation

    No full text
    The reliability and the health performance of network assets are of a great interest due to power network operators. This project investigates methods of developing a prognostic capability for evaluating the health and long term performance of ageing distribution cable circuits. From the instant of installation and operation, the insulating materials of a cable will begin to age as a result of a combination of mechanical, thermal and electrical factors. Development of simulation models can significantly improve the accuracy of prognostics, allowing the targeting of maintenance and reduction of in service failures [1]. Real-time measurements taken close to underground cables can update the simulation models giving a more accurate prognostic model.Currently the project investigates a thermal prognostic simulation model which will predict the likely temperature impact on a cable at burial depth according to weather conditions and known loading. Anomalies of temperature measurements along the cable compared to predicted temperatures will indicate a possible degradation activity in a cable. An experimental surface trough has been set up where operation of power cables is simulated with a control system which is able to model any cable loading. The surface temperature of the cable is continuously monitored as well as the weather conditions such as solar radiation, soil moisture content, wind speed, humidity, rainfall and air-temperature<br/

    Implementation of a novel online condition monitoring thermal prognostic indicator system

    No full text
    This research aims to develop a reliable and robust online condition monitoring thermal prognostic indicator system which will reduce the risk of failures in a Power System Network. Real-time measurements (weather conditions, temperature of the cable joints or terminations, loading demand) taken close to underground cable will update the prognostic simulation model. Anomalies of the measurements along the cable will be compared with the predicted ones hence indicating a possible degradation activity in the cable. The use of such systems within a power networks will provide a smarter way of prognostic condition monitoring in which you measure less and model more. The use of suggested thermal models will enable the power network operators to maximize asset utilization and minimize constraint costs in the system

    High frequency dynamics in liquid nickel: an IXS study

    Full text link
    Owing to their large relatively thermal conductivity, peculiar, non-hydrodynamic features are expected to characterize the acoustic-like excitations observed in liquid metals. We report here an experimental study of collective modes in molten nickel, a case of exceptional geophysical interest for its relevance in Earth interior science. Our result shed light on previously reported contrasting evidences: in the explored energy-momentum region no deviation from the generalized hydrodynamic picture describing non conductive fluids are observed. Implications for high frequency transport properties in metallic fluids are discussed.Comment: 6 pages, 4 figures, to appear in "Journal of Chemical Physics

    Broadband External-Cavity Diode Laser

    Get PDF
    A broadband external-cavity diode laser (ECDL) has been invented for use in spectroscopic surveys preparatory to optical detection of gases. Heretofore, commercially available ECDLs have been designed, in conjunction with sophisticated tuning assemblies, for narrow- band (and, typically, single-frequency) operation, as needed for high sensitivity and high spectral resolution in some gas-detection applications. However, for preparatory spectroscopic surveys, high sensitivity and narrow-band operation are not needed; in such cases, the present broadband ECDL offers a simpler, less-expensive, more-compact alternative to a commercial narrowband ECDL

    Internal Water Vapor Photoacoustic Calibration

    Get PDF
    Water vapor absorption is ubiquitous in the infrared wavelength range where photoacoustic trace gas detectors operate. This technique allows for discontinuous wavelength tuning by temperature-jumping a laser diode from one range to another within a time span suitable for photoacoustic calibration. The use of an internal calibration eliminates the need for external calibrated reference gases. Commercial applications include an improvement of photoacoustic spectrometers in all fields of use

    Does the 8−N8-N bonding rule break down in As2_2Se3_3 glass?

    Full text link
    The local coordination numbers of As2_2Se3_3 glass were determined by a combination of anomalous x-ray scattering experiments, reverse Monte Carlo calculations, and {\it ab initio} molecular dynamics simulations. The well-known `8-NN bonding rule' proposed by Mott breaks down around the As atoms, exceeding the rule by 7--26%. An experimental prediction based on mean-field theory agrees with the present experimental and theoretical results. The fourfold coordinated As atoms likely form As-As wrong bond chains rather than ethan-like configurations, which is identified as the origin for the breakdown of the `8-NN bonding rule'.Comment: 6 pages, 6figures, 1table, submitted to Europhysics Letter

    Wavelength-Agile External-Cavity Diode Laser for DWDM

    Get PDF
    A prototype external-cavity diode laser (ECDL) has been developed for communication systems utilizing dense wavelength- division multiplexing (DWDM). This ECDL is an updated version of the ECDL reported in Wavelength-Agile External- Cavity Diode Laser (LEW-17090), NASA Tech Briefs, Vol. 25, No. 11 (November 2001), page 14a. To recapitulate: The wavelength-agile ECDL combines the stability of an external-cavity laser with the wavelength agility of a diode laser. Wavelength is modulated by modulating the injection current of the diode-laser gain element. The external cavity is a Littman-Metcalf resonator, in which the zeroth-order output from a diffraction grating is used as the laser output and the first-order-diffracted light is retro-reflected by a cavity feedback mirror, which establishes one end of the resonator. The other end of the resonator is the output surface of a Fabry-Perot resonator that constitutes the diode-laser gain element. Wavelength is selected by choosing the angle of the diffracted return beam, as determined by position of the feedback mirror. The present wavelength-agile ECDL is distinguished by design details that enable coverage of all 60 channels, separated by 100-GHz frequency intervals, that are specified in DWDM standards

    Results of a Long-Term Demonstration of an Optical Multi-Gas Monitor on ISS

    Get PDF
    Previously at SAMAP we reported on the development of tunable diode laser spectroscopy (TDLS) based instruments for measuring small gas molecules in real time. TDLS technology has matured rapidly over the last 5 years as a result of advances in low power diode lasers as well as better detection schemes. In collaboration with two small businesses Vista Photonics, Inc. and Nanoracks LLC, NASA developed a 4 gas TDLS based monitor for an experimental demonstration of the technology on the International Space Station (ISS). Vista invented and constructed the core TDLS sensor. Nanoracks designed and built the enclosure, and certified the integrated monitor as a payload. The device, which measures oxygen, carbon dioxide, ammonia and water vapor, is called the Multi-Gas Monitor (MGM). MGM measures the 4 gases every few seconds and records a 30 second moving average of the concentrations. The relatively small unit draws only 2.5W. MGM was calibrated at NASA-Johnson Space Center in July 2013 and launched to ISS on a Soyuz vehicle in November 2013. Installation and activation of MGM occurred in February 2014, and the unit has been operating nearly continuously ever since in the Japanese Experiment Module. Data is downlinked from ISS about once per week. Oxygen and carbon dioxide data is compared with that from the central Major Constituents Analyzer. Water vapor data is compared with dew point measurements made by sensors in the Columbus module. The ammonia channel was tested by the crew using a commercial ammonia inhalant. MGM is remarkably stable to date. Results of 18 months of operation are presented and future applications including combustion product monitoring are discussed

    Transformer Oil Passivation and Impact of Corrosive Sulphur

    No full text
    In recent years a significant volume of research has been undertaken in order to understand the recent failures in oil insulated power apparatus due to deposition of copper sulphide on the conductors and in the insulation paper. Dibenzyl Disulfide (DBDS) has been found to be the leading corrosive sulphur compound in the insulation oil [1]. The process of copper sulphide formation and the deposition in the paper is still being investigated, but a recently proposed method seems to be gaining some confidence [1]. This method suggests a two-step process; initially the DBDS and some oil soluble copper complexes are formed. Secondly the copper complexes are absorbed in the paper insulation, where they then decompose into copper sulphide [2]. The most commonly used mitigating technique for corrosive sulphur contaminated oil is passivation, normally using Irgamet 39 or 1, 2, 3-benzotriazole (BTA). The passivator is diluted into the oil to a concentration of around 100ppm, where it then reacts with the copper conductors to form a complex layer around the copper, preventing it from interacting with DBDS compounds and forming copper sulphide. This research project will investigate the electrical properties of HV transformers which have tested positive for corrosive sulphur, and the evolution of those properties as the asset degrades due to sulphur corrosion. Parallel to this the long term properties of transformers with passivated insulation oil will be analysed in order to understand the passivator stability and whether it is necessary to keep adding the passivator to sustain its performance. Condition monitoring techniques under investigation will include dielectric spectroscopy, frequency response analysis, recovery voltage method (aka interfacial polarisation) amongst others. Partial discharge techniques will not be investigated, as the voltage between the coil plates is low and therefore it will not contribute significantly to the overall insulation breakdown, in corrosive oil related faults [3]. The goal of this research is to establish key electrical properties in both passivated and non-passivated power transformers that demonstrate detectable changes as the equipment degrades due to the insulation oil being corrosive
    • …
    corecore