8 research outputs found

    Pre-treatment high-sensitivity troponin T for the short-term prediction of cardiac outcomes in patients on immune checkpoint inhibitors

    Get PDF
    Background: Immune checkpoint inhibitors (ICIs) are an emerging option for several advanced metastatic cancers, but may have cardiotoxic effects. The prognostic value of high-sensitivity troponin T (hs-TnT) before treatment start has never been investigated. Materials and methods: Thirty consecutive patients underwent measurement of hs-TnT before starting ICI therapy (pembrolizumab, 23%; nivolumab, 12%; atezolizumab, 6%; durvalumab, 5%). The primary endpoint of cardiovascular death, stroke or transient ischaemic attack, pulmonary embolism and new-onset heart failure, and the secondary endpoint of progression of cardiac involvement according to the CARDIOTOX classification were evaluated after 3 months from the first cycle. Results: Patients (median age 68 years, 77% men, 13% with coronary artery disease, 90% current or former smokers, 67% overweight or obese and 43% hypertensive) had a median hs-TnT of 12 ng/L (interquartile interval 8-23). The primary endpoint occurred only in patients with hs-TnT ≥ 14 ng/L at baseline. Therefore, only patients who had hs-TnT ≥ 14 ng/L before the first cycle died had a stroke/TIA or new-onset HF. Furthermore, nine out of 13 patients with the secondary endpoint (progression of cardiac disease) had hs-TnT ≥ 14 ng/L before the first cycle (P =.012). AUC values were 0.909 for the primary endpoint and 0.757 for the secondary endpoint. The best cut-off was 14 ng/L for both the primary (100% sensitivity, 73% specificity) and secondary endpoints (sensitivity 75%, specificity 77%). Conclusions: In patients on ICIs, baseline hs-TnT predicts a composite cardiovascular endpoint and the progression of cardiac involvement at 3 months, with 14 ng/L as the best cut-off

    Legionella anisa or Legionella bozemanii? Traditional and molecular techniques as support in the environmental surveillance of a hospital water network

    Get PDF
    Understanding the actual distribution of different Legionella species in water networks would help prevent outbreaks. Culture investigations followed by serological agglutination tests, with poly/monovalent antisera, still represent the gold standard for isolation and identification of Legionella strains. However, also MALDI-TOF and mip-gene sequencing are currently used. This study was conducted to genetically correlate strains of Legionella non pneumophila (L-np) isolated during environmental surveillance comparing different molecular techniques. Overall, 346 water samples were collected from the water system of four pavilions located in a hospital of the Apulia Region of Italy. Strains isolated from the samples were then identified by serological tests, MALDI-TOF, and mip-gene sequencing. Overall, 24.9% of water samples were positive for Legionella, among which the majority were Legionella pneumophila (Lpn) 1 (52.3%), followed by Lpn2-15 (20.9%), L-np (17.4%), Lpn1 + Lpn2-15 (7.1%), and L-np + Lpn1 (2.3%). Initially, L-np strains were identified as L. bozemanii by monovalent antiserum, while MALDI-TOF and mip-gene sequencing assigned them to L. anisa. More cold water than hot water samples were contaminated by L. anisa (p < 0.001). PFGE, RAPD, Rep-PCR, and SAU-PCR were performed to correlate L. anisa strains. Eleven out of 14 strains identified in all four pavilions showed 100% of similarity upon PFGE analysis. RAPD, Rep-PCR, and SAU-PCR showed greater discriminative power than PFGE

    The rapid spread of SARS-COV-2 Omicron variant in Italy reflected early through wastewater surveillance

    Get PDF
    The SARS-CoV-2 Omicron variant emerged in South Africa in November 2021, and has later been identified worldwide, raising serious concerns. A real-time RT-PCR assay was designed for the rapid screening of the Omicron variant, targeting characteristic mutations of the spike gene. The assay was used to test 737 sewage samples collected throughout Italy (19/21 Regions) between 11 November and 25 December 2021, with the aim of assessing the spread of the Omicron variant in the country. Positive samples were also tested with a real-time RT-PCR developed by the European Commission, Joint Research Centre (JRC), and through nested RT-PCR followed by Sanger sequencing. Overall, 115 samples tested positive for Omicron SARS-CoV-2 variant. The first occurrence was detected on 7 December, in Veneto, North Italy. Later on, the variant spread extremely fast in three weeks, with prevalence of positive wastewater samples rising from 1.0% (1/104 samples) in the week 5–11 December, to 17.5% (25/143 samples) in the week 12–18, to 65.9% (89/135 samples) in the week 19–25, in line with the increase in cases of infection with the Omicron variant observed during December in Italy. Similarly, the number of Regions/Autonomous Provinces in which the variant was detected increased from one in the first week, to 11 in the second, and to 17 in the last one. The presence of the Omicron variant was confirmed by the JRC real-time RT-PCR in 79.1% (91/115) of the positive samples, and by Sanger sequencing in 66% (64/97) of PCR amplicons. In conclusion, we designed an RT-qPCR assay capable to detect the Omicron variant, which can be successfully used for the purpose of wastewater-based epidemiology. We also described the history of the introduction and diffusion of the Omicron variant in the Italian population and territory, confirming the effectiveness of sewage monitoring as a powerful surveillance tool

    Oral anticoagulation in patients with atrial fibrillation and stage 4 or 5 chronic kidney disease

    No full text
    Patients with chronic kidney disease (CKD) have a high prevalence of atrial fibrillation (AF). Stroke in patients with CKD and AF is frequent, and is usually more severe than in the absence of CKD. Current European Society of Cardiology guidelines recommend oral anticoagulant therapy in order to reduce thromboembolic risk in AF patients in general, and also in the presence of CKD, excluding however stage 4 and dialysis (stage 5) patients. Warfarin and other vitamin K antagonists are still the most frequently used drugs in these settings, despite the high bleeding risk. In the United States, the non-vitamin K antagonist oral anticoagulants, especially apixaban, are here used off-label, despite the absence of strong evidences of efficacy and safety. Several clinical trials are ongoing, and further evidence is needed before non-vitamin K antagonists can be recommended in these patients

    The rapid spread of SARS-COV-2 Omicron variant in Italy reflected early through wastewater surveillance

    Get PDF
    The SARS-CoV-2 Omicron variant emerged in South Africa in November 2021, and has later been identified worldwide, raising serious concerns. A real-time RT-PCR assay was designed for the rapid screening of the Omicron variant, targeting characteristic mutations of the spike gene. The assay was used to test 737 sewage samples collected throughout Italy (19/21 Regions) between 11 November and 25 December 2021, with the aim of assessing the spread of the Omicron variant in the country. Positive samples were also tested with a real-time RT-PCR developed by the European Commission, Joint Research Centre (JRC), and through nested RT-PCR followed by Sanger sequencing. Overall, 115 samples tested positive for Omicron SARS-CoV-2 variant. The first occurrence was detected on 7 December, in Veneto, North Italy. Later on, the variant spread extremely fast in three weeks, with prevalence of positive wastewater samples rising from 1.0% (1/104 samples) in the week 5–11 December, to 17.5% (25/143 samples) in the week 12–18, to 65.9% (89/135 samples) in the week 19–25, in line with the increase in cases of infection with the Omicron variant observed during December in Italy. Similarly, the number of Regions/Autonomous Provinces in which the variant was detected increased from one in the first week, to 11 in the second, and to 17 in the last one. The presence of the Omicron variant was confirmed by the JRC real-time RT-PCR in 79.1% (91/115) of the positive samples, and by Sanger sequencing in 66% (64/97) of PCR amplicons. In conclusion, we designed an RT-qPCR assay capable to detect the Omicron variant, which can be successfully used for the purpose of wastewater-based epidemiology. We also described the history of the introduction and diffusion of the Omicron variant in the Italian population and territory, confirming the effectiveness of sewage monitoring as a powerful surveillance tool

    Wastewater surveillance of SARS-CoV-2 variants in October–November 2022 in Italy: detection of XBB.1, BA.2.75 and rapid spread of the BQ.1 lineage

    No full text
    This study adds insight regarding the occurrence and spread of SARS-CoV-2 Variants of Concern (VOCs) and Variants of Interest (VOIs) in Italy in October and November 2022, by testing urban wastewater collected throughout the country. A total of 332 wastewater samples were collected from 20 Italian Regions/Autonomous Provinces (APs) within the framework of national SARS-CoV-2 environmental surveillance. Of these, 164 were collected in the first week of October and 168 in the first week of November. A ∼1600 bp fragment of the spike protein was sequenced by Sanger (for individual samples) and long-read nanopore sequencing (for pooled Region/AP samples). In October, mutations characteristic of Omicron BA.4/BA.5 were detected in the vast majority (91 %) of the samples amplified by Sanger sequencing. A fraction of these sequences (9 %) also displayed the R346T mutation. Despite the low prevalence documented in clinical cases at the time of sampling, amino acid substitutions characteristic of sublineages BQ.1 or BQ.1.1 were detected in 5 % of sequenced samples from four Regions/APs. A significantly higher variability of sequences and variants was documented in November 2022, when the rate of sequences harbouring mutations of lineages BQ.1 and BQ1.1 increased to 43 %, and the number of Regions/APs positive for the new Omicron subvariant more than tripled (n = 13) compared to October. Moreover, an increase in the number of sequences with the mutation package BA.4/BA.5 + R346T (18 %), as well as the detection of variants never observed before in wastewater in Italy, such as BA.2.75 and XBB.1 (the latter in a Region where no clinical cases associated with this variant had ever been documented) was recorded. The results suggest that, as predicted by the ECDC, BQ.1/BQ.1.1 is rapidly becoming dominant in late 2022. Environmental surveillance proves to be a powerful tool for tracking the spread of SARS-CoV-2 variants/subvariants in the population
    corecore