28 research outputs found

    Limited clinical value of two consecutive post-transplant renal scintigraphy procedures

    Get PDF
    Objectives: Duration of delayed graft function (DGF) and length of hospital stay (LOS) are outcomes of interest in an era that warrants increased efficacy of transplant care whereas renal allografts originate increasingly from marginal donors. While earlier studies investigate the predictive capability of a single renal scintigraphy, this study focuses on the value for both DGF duration and LOS of consecutively performed scintigraphies. Methods: From 2011 to 2014, renal transplant recipients referred for a Tc-99m MAG3 renal scintigraphy were included in a single-center retrospective study. Primary endpoints were DGF duration and LOS. Both the first (≀ 3Β days) and second scintigraphies (3–7Β days after transplantation) were analyzed using a 4-grade qualitative scale and quantitative indices (TFS, cTER, MUC10, average upslope). Results: We evaluated 200 first and 108 (54%) consecutively performed scintigraphies. The Kaplan-Meier curves for DGF duration and qualitative grading of the first and second scintigraphy showed significant differences between the grades (p < 0.01). The Kaplan-Meier curve for the delta grades between these procedures (lower, equal, or higher grade) did not show significant differences (p = 0.18). Multivariate analysis showed a significant association between the qualitative grades, from the first and second scintigraphy, and DGF duration, HR 1.8 (1.4–2.2, p < 0.01) and 2.8 (1.8–4.3, p < 0.01), respectively. Conclusions: Qualitative grades of single renal scintigraphies, performed within 7Β days after transplantation, can be used to make a reliable image-guided decision on the need for dialysis and to predict LOS. A consecutive renal scintigraphy, however, did not show an additional value in the assessment of DGF. Key Points: β€’ Post-transplant renal scintigraphy procedures provide information to predict delayed graft function duration and length of hospital stay. β€’ Performing two consecutive renal scintigraphy procedures within 1Β week after transplantation does not strengthen the prediction of delayed graft function duration and length of hospital stay. β€’ Single renal scintigraphy procedures can be used to provide clinicians and patients with a reliable indication of the need for dialysis after transplantation and the expected duration of hospitalization

    Baseline and early digital [<sup>18</sup>F]FDG PET/CT and multiparametric MRI contain promising features to predict response to neoadjuvant therapy in locally advanced rectal cancer patients:a pilot study

    Get PDF
    Objective In this pilot study, we investigated the feasibility of response prediction using digital [18F]FDG PET/computed tomography (CT) and multiparametric MRI before, during, and after neoadjuvant chemoradiation therapy in locally advanced rectal cancer (LARC) patients and aimed to select the most promising imaging modalities and timepoints for further investigation in a larger trial. Methods Rectal cancer patients scheduled to undergo neoadjuvant chemoradiation therapy were prospectively included in this trial, and underwent multiparametric MRI and [18F]FDG PET/CT before, 2 weeks into, and 6-8 weeks after chemoradiation therapy. Two groups were created based on pathological tumor regression grade, that is, good responders (TRG1-2) and poor responders (TRG3-5). Using binary logistic regression analysis with a cutoff value of P ≀ 0.2, promising predictive features for response were selected. Results Nineteen patients were included. Of these, 5 were good responders, and 14 were poor responders. Patient characteristics of these groups were similar at baseline. Fifty-seven features were extracted, of which 13 were found to be promising predictors of response. Baseline [T2: volume, diffusion-weighted imaging (DWI): apparent diffusion coefficient (ADC) mean, DWI: difference entropy], early response (T2: volume change, DWI: ADC mean change) and end-of-treatment presurgical evaluation MRI (T2: gray level nonuniformity, DWI: inverse difference normalized, DWI: gray level nonuniformity normalized), as well as baseline (metabolic tumor volume, total lesion glycolysis) and early response PET/CT (Ξ” maximum standardized uptake value, Ξ” peak standardized uptake value corrected for lean body mass), were promising features. Conclusion Both multiparametric MRI and [18F]FDG PET/CT contain promising imaging features to predict response to neoadjuvant chemoradiotherapy in LARC patients. A future larger trial should investigate baseline, early response, and end-of-treatment presurgical evaluation MRI and baseline and early response PET/CT.</p

    Intramyocardial Injection of Autologous Bone Marrow-Derived Ex Vivo Expanded Mesenchymal Stem Cells in Acute Myocardial Infarction Patients is Feasible and Safe up to 5 Years of Follow-up

    Get PDF
    Abstract In experimental studies, mesenchymal stem cell (MSC) transplantation in acute myocardial infarction (AMI) models has been associated with enhanced neovascularization and myogenesis. Clinical data however, are scarce. Therefore, the present study evaluates the safety and feasibility of intramyocardial MSC injection in nine patients, shortly after AMI during short-term and 5-year follow-up. Periprocedural safety analysis demonstrated one transient ischemic attack. No other adverse events related to MSC treatment were observed during 5-year follow-up. Clinical events were compared to a nonrandomized control group comprising 45 matched controls. A 5-year event-free survival after MSC-treatment was comparable to controls (89 vs. 91 %, P =0.87). Echocardiographic imaging for evaluation of left ventricular function demonstrated improvements up to 5 years after MSC treatment. These findings were not significantly different when compared to controls. The present safety and feasibility study suggest that intramyocardial injection of MSC in patients shortly after AMI is feasible and safe up to 5-year follow-up

    The consequences of a new software package for the quantification of gated-SPECT myocardial perfusion studies

    Get PDF
    Semiquantitative analysis of myocardial perfusion scintigraphy (MPS) has reduced inter- and intraobserver variability, and enables researchers to compare parameters in the same patient over time, or between groups of patients. There are several software packages available that are designed to process MPS data and quantify parameters. In this study the performances of two systems, quantitative gated SPECT (QGS) and 4D-MSPECT, in the processing of clinical patient data and phantom data were compared. The clinical MPS data of 148 consecutive patients were analysed using QGS and 4D-MSPECT to determine the end-diastolic volume, end-systolic volume and left ventricular ejection fraction. Patients were divided into groups based on gender, body mass index, heart size, stressor type and defect type. The AGATE dynamic heart phantom was used to provide reference values for the left ventricular ejection fraction. Although the correlations were excellent (correlation coefficients 0.886 to 0.980) for all parameters, significant differences (p < 0.001) were found between the systems. Bland-Altman plots indicated that 4D-MSPECT provided overall higher values of all parameters than QGS. These differences between the systems were not significant in patients with a small heart (end-diastolic volume < 70 ml). Other clinical factors had no direct influence on the relationship. Additionally, the phantom data indicated good linear responses of both systems. The discrepancies between these software packages were clinically relevant, and influenced by heart size. The possibility of such discrepancies should be taken into account when a new quantitative software system is introduced, or when multiple software systems are used in the same institution.Vascular Biology and Interventio

    Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECT

    Get PDF
    The aim of the current study was to evaluate the relationship between the site of latest mechanical activation as assessed with gated myocardial perfusion SPECT (GMPS), left ventricular (LV) lead position and response to cardiac resynchronization therapy (CRT). The patient population consisted of consecutive patients with advanced heart failure in whom CRT was currently indicated. Before implantation, 2-D echocardiography and GMPS were performed. The echocardiography was performed to assess LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV) and LV ejection fraction (LVEF). The site of latest mechanical activation was assessed by phase analysis of GMPS studies and related to LV lead position on fluoroscopy. Echocardiography was repeated after 6 months of CRT. CRT response was defined as a decrease of a parts per thousand yen15% in LVESV. Enrolled in the study were 90 patients (72% men, 67 +/- 10 years) with advanced heart failure. In 52 patients (58%), the LV lead was positioned at the site of latest mechanical activation (concordant), and in 38 patients (42%) the LV lead was positioned outside the site of latest mechanical activation (discordant). CRT response was significantly more often documented in patients with a concordant LV lead position than in patients with a discordant LV lead position (79% vs. 26%, p < 0.01). After 6 months, patients with a concordant LV lead position showed significant improvement in LVEF, LVESV and LVEDV (p < 0.05), whereas patients with a discordant LV lead position showed no significant improvement in these variables. Patients with a concordant LV lead position showed significant improvement in LV volumes and LV systolic function, whereas patients with a discordant LV lead position showed no significant improvements.Cardiovascular Aspects of Radiolog

    Cardiac autonomic neuropathy in patients with diabetes and no symptoms of coronary artery disease: comparison of 123I-metaiodobenzylguanidine myocardial scintigraphy and heart rate variability

    Get PDF
    PURPOSE The purpose of this study was to evaluate the prevalence of cardiac autonomic neuropathy (CAN) in a cohort of patients with type 2 diabetes, truly asymptomatic for coronary artery disease (CAD), using heart rate variability (HRV) and (123)I-metaiodobenzylguanidine ((123)I-mIBG) myocardial scintigraphy. METHODS The study group comprised 88 patients with type 2 diabetes prospectively recruited from an outpatient diabetes clinic. In all patients myocardial perfusion scintigraphy, CAN by HRV and (123)I-mIBG myocardial scintigraphy were performed. Two or more abnormal tests were defined as CAN-positive (ECG-based CAN) and one or fewer as CAN-negative. CAN assessed by (123)I-mIBG scintigraphy was defined as abnormal if the heart-to-mediastinum ratio was 25%, or the total defect score was >13. RESULTS The prevalence of CAN in patients asymptomatic for CAD with type 2 diabetes and normal myocardial perfusion assessed by HRV and (123)I-mIBG scintigraphy was respectively, 27% and 58%. Furthermore, in almost half of patients with normal HRV, (123)I-mIBG scintigraphy showed CAN. CONCLUSION The current study revealed a high prevalence of CAN in patients with type 2 diabetes. Secondly, disagreement between HRV and (123)I-mIBG scintigraphy for the assessment of CAN was observed.Cardiovascular Aspects of Radiolog

    Nuclear medicine imaging methods of radiation-induced cardiotoxicity

    Get PDF
    Breast cancer survival is significantly improved over the past decades due to major improvements in anti-tumor therapies and the implementation of regular screening, which leads to early detection of breast cancer. Therefore, it is of utmost importance to prevent patients from long-term side effects, including radiotherapy-induced cardiotoxicity. Radiotherapy may contribute to damage of myocardial structures on the cellular level, which eventually could result in various types of cardiovascular problems, including coronary artery disease and (non-)ischemic cardiomyopathy, leading to heart failure. These cardiac complications of radiotherapy are preceded by alterations in myocardial perfusion and blood flow. Therefore, early detection of these alterations is important to prevent the progression of these pathophysiological processes. Several radionuclide imaging techniques may contribute to the early detection of these changes. Single-Photon Emission Computed Tomography (SPECT) cameras can be used to create Multigated Acquisition scans in order to assess the left ventricular systolic and diastolic function. Furthermore, SPECT cameras are used for myocardial perfusion imaging with radiopharmaceuticals such as 99mTc-sestamibi and 99mTc-tetrofosmin. Accurate quantitative measurement of myocardial blood flow (MBF), can be performed by Positron Emission Tomography (PET), as the uptake of some of the tracers used for PET-based MBF measurement almost creates a linear relationship with MBF, resulting in very accurate blood flow quantification. Furthermore, there are PET and SPECT tracers that can assess inflammation and denervation of the cardiac sympathetic nervous system. Research over the past decades has mainly focused on the long-term development of left ventricular impairment and perfusion defects. Considering laterality of the breast cancer, some early studies have shown that women irradiated for left-sided breast cancer are more prone to cardiotoxic side effects than women irradiated for right-sided breast cancer. The left-sided radiation field in these trials, which predominantly used older radiotherapy techniques without heart-sparing techniques, included a larger volume of the heart and left ventricle, leading to increased unavoidable radiation exposure to the heart due to the close proximity of the radiation treatment volume. Although radiotherapy for breast cancer exposes the heart to incidental radiation, several improvements and technical developments over the last decades resulted in continuous reduction of radiation dose and volume exposure to the heart. In addition, radiotherapy reduces loco-regional tumor recurrences and death from breast cancer and improves survival. Therefore, in the majority of patients, the benefits of radiotherapy outweigh the potential very low risk of cardiovascular adverse events after radiotherapy. This review addresses existing nuclear imaging techniques, which can be used to evaluate (long-term) effects of radiotherapy-induced mechanical cardiac dysfunction and discusses the potential use of more novel nuclear imaging techniques, which are promising in the assessment of early signs of cardiac dysfunction in selected irradiated breast cancer patients
    corecore