280 research outputs found
Educational Outcomes of Small-Group Discussion Versus Traditional Lecture Format in Dental Students\u27 Learning and Skills Acquisition.
The aim of this prospective quantitative study was to compare the effect of different instructional formats on dental students\u27 skills and knowledge acquisition for access cavity preparation. All first-year dental students were invited to participate in this study conducted during the four consecutive two-week endodontic rotation courses at the University of the Pacific Arthur A. Dugoni School of Dentistry in spring semester 2015. Four alphabetically distributed intact groups of students were randomly allocated to two groups (n=70 each) that participated in either small-group discussion or a traditional lecture on access preparation. The first outcome measure was skill acquisition, measured by the quality of access cavities prepared in extracted teeth at the conclusion of the session. Two blinded raters scored direct observations on a continuous scale. Knowledge, the second outcome measure, was scored with a multiple-choice and open-ended question test at the end of each two-week session. Data were obtained for 134 of the 140 students, for a 96% response rate. The results showed that students in the small-group discussion groups scored significantly higher than those in the lecture groups when skill performance was tested (p=8.9 Ă 10(-7)). However, no significant differences were found in the acquisition of knowledge between the two groups on the written test. Active student participation was significantly related to improved manual skill acquisition, but the format of the session does not seem to have had a direct influence on acquired knowledge
Demetallization of Enterococcus faecalis Biofilm: A preliminary study
Objectives: To determine the concentration of calcium, iron, manganese and zinc ions after the application of chelator to Enterococcus faecalis biofilms.
Material and Methods: Fifty bovine maxillary central incisors were prepared and inoculated with E. faecalis for 60 days. The following were used as irrigation solutions: 17% EDTA (pH 3, 7 and 10), 2.5% sodium hypochlorite (NaOCl) combined with 17% EDTA (pH 3, 7 and 10), distilled water (pH 3, 7 and 10), and 2.5% NaOCl. Each solution was kept in the root canal for five minutes. Fifteen uncontaminated root canals were irrigated with 17% EDTA (pH 3, 7 and 10). Six teeth were used as bacterial control. The number of calcium, iron, manganese and zinc ions was determined using flame atomic absorption spectrometry. Mean ± standard deviation (SD) values were used for descriptive statistics.
Results: Calcium chelation using 17% EDTA at pH 7 was higher than at pH 3 and 10, regardless of whether bacterial biofilm was present. The highest concentration of iron occurred at pH 3 in the presence of bacterial biofilm. The highest concentration of manganese found was 2.5% NaOCl and 17% EDTA at pH 7 in the presence of bacterial biofilm. Zinc levels were not detectable.
Conclusions: The pH of chelating agents affected the removal of calcium, iron, and manganese ions. The concentration of iron ions in root canals with bacterial biofilm was higher after the use of 17% EDTA at pH 3 than after the use of the other solutions at all pH levels
Jean-Marc Leveratto, Mary Leontsini, Internet et la sociabilité littéraire
Sur la quatriĂšme de couverture de cet ouvrage que complĂšte une courte « prĂ©sentation » liminaire, Jean-Marc Leveratto et Mary Leontsini tĂ©moignent dâun double projet : dâune part, dĂ©velopper la recherche sociologique sur les pratiques de la lecture ; dâautre part, prĂ©ciser la spĂ©cificitĂ© et la place du mĂ©dia internet dans le dĂ©veloppement de la sociabilitĂ© littĂ©raire. Lâambition de lâĂ©tude est donc dâabord Ă©pistĂ©mologique, car elle vise Ă observer avant tout la complexitĂ© des mĂ©diations et de..
Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT.
OBJECTIVES: The various types of cone beam CT (CBCT) differ in several technical characteristics, notably their spatial resolution, which is defined by the acquisition voxel size. However, data are still lacking on the effects of voxel size on the metric accuracy of three-dimensional (3D) reconstructions. This study was designed to assess the effect of isotropic voxel size on the 3D reconstruction accuracy and reproducibility of CBCT data.
METHODS: The study sample comprised 70 teeth (from the Institut d\u27Anatomie Normale, Strasbourg, France). The teeth were scanned with a KODAK 9500 3DÂź CBCT (Carestream Health, Inc., Marne-la-VallĂ©e, France), which has two voxel sizes: 200 ”m (CBCT 200 ”m group) and 300 ”m (CBCT 300 ”m group). These teeth had also been scanned with the KODAK 9000 3DÂź CBCT (Carestream Health, Inc.) (CBCT 76 ”m group) and the SCANCO Medical micro-CT XtremeCT (SCANCO Medical, BrĂŒttisellen, Switzerland) (micro-CT 41 ”m group) considered as references. After semi-automatic segmentation with AMIRAÂź software (Visualization Sciences Group, Burlington, MA), tooth volumetric measurements were obtained.
RESULTS: The Bland-Altman method showed no difference in tooth volumes despite a slight underestimation for the CBCT 200 ”m and 300 ”m groups compared with the two reference groups. The underestimation was statistically significant for the volumetric measurements of the CBCT 300 ”m group relative to the two reference groups (Passing-Bablok method).
CONCLUSIONS: CBCT is not only a tool that helps in diagnosis and detection but it has the complementary advantage of being a measuring instrument, the accuracy of which appears connected to the size of the voxels. Future applications of such measurements with CBCT are discussed
Demetallization of Enterococcus faecalis biofilm: a preliminary study
Objectives To determine the concentration of calcium, iron, manganese and zinc ions after the application of chelator to Enterococcus faecalis biofilms. Material and Methods Fifty bovine maxillary central incisors were prepared and inoculated with E. faecalis for 60 days. The following were used as irrigation solutions: 17% EDTA (pH 3, 7 and 10), 2.5% sodium hypochlorite (NaOCl) combined with 17% EDTA (pH 3, 7 and 10), distilled water (pH 3, 7 and 10), and 2.5% NaOCl. Each solution was kept in the root canal for five minutes. Fifteen uncontaminated root canals were irrigated with 17% EDTA (pH 3, 7 and 10). Six teeth were used as bacterial control. The number of calcium, iron, manganese and zinc ions was determined using flame atomic absorption spectrometry. Mean ± standard deviation (SD) values were used for descriptive statistics. Results Calcium chelation using 17% EDTA at pH 7 was higher than at pH 3 and 10, regardless of whether bacterial biofilm was present. The highest concentration of iron occurred at pH 3 in the presence of bacterial biofilm. The highest concentration of manganese found was 2.5% NaOCl and 17% EDTA at pH 7 in the presence of bacterial biofilm. Zinc levels were not detectable. Conclusions The pH of chelating agents affected the removal of calcium, iron, and manganese ions. The concentration of iron ions in root canals with bacterial biofilm was higher after the use of 17% EDTA at pH 3 than after the use of the other solutions at all pH levels
VISIĂN AĂREA DE LA LAGUNA DE VALLESECO [Material grĂĄfico]
Copia digital. Madrid : Ministerio de EducaciĂłn, Cultura y Deporte, 201
Nanomechanical Properties of Endodontically Treated Teeth
Abstract Introduction: Although it is apparent that teeth become more susceptible to fracture after root canal treatment, the contributing factors for this are not completely established. The purpose of this study was to determine whether there are changes in nanomechanical properties of dentin in root canal-treated teeth compared with non-root canal-treated control teeth. Methods: Atomic force microscopy-based nanoindentation testing was performed on root canal-treated teeth and age-and type-matched control teeth. Radicular intertubular dentin was indented in 6 locations, and triplicate measurements were averaged. Paired t tests were used to compare root canal-treated teeth with control teeth. Results: The moduli of elasticity were 17.8 AE 2.9 GPa and 18.9 AE 2.9 GPa for root canal-treated teeth and controls, respectively; the hardness values for the 2 groups were 0.84 AE 0.25 GPa and 0.84 AE 0.18 GPa, respectively. Neither the modulus of elasticity nor the hardness differed between groups (P > .05). Conclusions: It appears that root canal treatment does not result in nanomechanical changes to radicular intertubular dentin. (J Endod 2011;37:1562-156
Evaluation of cyclic fatigue and bending resistance of coronal preflaring niti file manufactured with different heat treatments
Coronal preflaring NiTi files should possess proper hardness, resistance to fracture and flexibility. This study compared the bending resistance and cyclic fatigue resistance of three orifice preflaring NiTi files. HyFlex EDM Orifice opener (#25/12), HyFlex CM (#25/08) and One Flare (#25/09) were tested (n = 46/instrument). Bending resistance was assessed with the stress when perpendicular displacement was applied to a 3 mm point from the file tip, and was performed at either room temperature (RT, n = 10) or body temperature (BT, n = 10). Cyclic fatigue resistance was tested with an artificial ceramic root canal at RT (n = 10) and BT (n = 10), and the number of cycles to failure (NCF) was obtained. The bending resistance and the NCF results were analyzed by two-way ANOVA and Tukeyâs test. Differential scanning calorimetry (DSC) and X-ray diffraction (XRD) analyses were performed (n = 3, respectively). HyFlex EDM exhibited the highest bending resistance, followed by One Flare and HyFlex CM (p \u3c 0.05), irrespective of the tested temperature. At RT, HyFlex CM demonstrated the highest NCF (p = 0.001), while HyFlex EDM had the highest NCF at BT (p \u3c 0.001). The tested NiTi files were composed of austenite and martensite according to the DSC and XRD results. HyFlex EDM had the highest bending resistance and NCF measured at BT
Applying the FAIR Principles to Computational Workflows
Recent trends within computational and data sciences show an increasing recognition and adoption of computational workflows as tools for productivity, reproducibility, and democratized access to platforms and processing know-how. As digital objects to be shared, discovered, and reused, computational workflows benefit from the FAIR principles, which stand for Findable, Accessible, Interoperable, and Reusable. The Workflows Community Initiative's FAIR Workflows Working Group (WCI-FW), a global and open community of researchers and developers working with computational workflows across disciplines and domains, has systematically addressed the application of both FAIR data and software principles to computational workflows. We present our recommendations with commentary that reflects our discussions and justifies our choices and adaptations. Like the software and data principles on which they are based, these are offered to workflow users and authors, workflow management system developers, and providers of workflow services as guide rails for adoption and fodder for discussion. Workflows are becoming more prevalent as documented, automated instruments for data analysis, data collection, AI-based predictions, and simulations. The FAIR recommendations for workflows that we propose in this paper will maximize their value as research assets and facilitate their adoption by the wider community
PRILE 2021 guidelines for reporting laboratory studies in Endodontology: explanation and elaboration
Guidance to authors is needed to prevent their waste of talent, time and resources in writing manuscripts that will never be published in the highest-quality journals. Laboratory studies are probably the most common type of endodontic research projects because they make up the majority of manuscripts submitted for publication. Unfortunately, most of these manuscripts fail the peer-review process, primarily due to critical flaws in the reporting of the methods and results. Here, in order to guide authors, the Preferred Reporting Items for study Designs in Endodontology (PRIDE) team developed new reporting guidelines for laboratory-based studies: the Preferred Reporting Items for Laboratory studies in Endodontology (PRILE) 2021 guidelines. The PRILE 2021 guidelines were developed exclusively for the area of Endodontology by integrating and adapting the modified CONSORT checklist of items for reporting in vitro studies of dental materials and the Clinical and Laboratory Images in Publications (CLIP) principles. The process of developing the PRILE 2021 guidelines followed the recommendations of the Guidance for Developers of Health Research Reporting Guidelines. The aim of the current document is to provide authors with an explanation for each of the items in the PRILE 2021 checklist and flowchart with examples from the literature, and to provide advice from peer-reviewers and editors about how to solve each problem in manuscripts prior to their peer-review. The Preferred Reporting Items for study Designs in Endodontology (PRIDE) website (http://pride-endodonticguidelines.org/prile/) provides a link to the PRILE 2021 explanation and elaboration document as well as to the checklist and flowchart
- âŠ