48 research outputs found

    Oral Thromboprophylaxis Following Total Hip or Knee Replacement: Review and Multicentre Experience with Dabigatran Etexilate

    Get PDF
    The risk of venous thromboembolism (VTE) in patients undergoing total knee or hip replacement surgery is high. As a result, thromboprophylaxis is highly recommended. While current thromboprophylactic agents, such as low molecular weight heparins (LMWH) and vitamin K antagonists, are safe and effective their use can be problematic. Therefore, there is a need for alternative anticoagulants that are as safe and effective as conventional agents, but are more convenient and easier to use. Dabigatran etexilate, a direct thrombin inhibitor, is one such anticoagulant. For VTE prevention following major orthopaedic surgery, dabigatran etexilate shows similar efficacy and safety to the LMWH enoxaparin, and is approved for use in more than 75 countries, including Europe and Canada. Here, we summarize and discuss the experiences of four German clinics that have recently introduced dabigatran etexilate into clinical practice. Overall, dabigatran etexilate was well received by patients, surgeons and nurses, and compared favourably with enoxaparin. Staff appreciated the oral, single-dose administration of dabigatran etexilate. Patient satisfaction was high, especially in those individuals who had previously used LMWHs. In this review, we also address a number of questions that were asked by patients or staff; this will be of relevance to orthopaedic surgeons and nurses. We conclude that, in these four German clinics, dabigatran etexilate offered an effective oral alternative to existing thromboprophylactic agents in patients undergoing major orthopaedic surgery

    Clinical application of scaffolds for cartilage tissue engineering

    Get PDF
    The purpose of this paper is to review the basic science and clinical literature on scaffolds clinically available for the treatment of articular cartilage injuries. The use of tissue-engineered grafts based on scaffolds seems to be as effective as conventional ACI clinically. However, there is limited evidence that scaffold techniques result in homogeneous distribution of cells. Similarly, few studies exist on the maintenance of the chondrocyte phenotype in scaffolds. Both of which would be potential advantages over the first generation ACI. The mean clinical score in all of the clinical literature on scaffold techniques significantly improved compared with preoperative values. More than 80% of patients had an excellent or good outcome. None of the short- or mid-term clinical and histological results of these tissue-engineering techniques with scaffolds were reported to be better than conventional ACI. However, some studies suggest that these methods may reduce surgical time, morbidity, and risks of periosteal hypertrophy and post-operative adhesions. Based on the available literature, we were not able to rank the scaffolds available for clinical use. Firm recommendations on which cartilage repair procedure is to be preferred is currently not known on the basis of these studies. Randomized clinical trials and longer follow-up periods are needed for more widespread information regarding the clinical effectiveness of scaffold-based, tissue-engineered cartilage repair

    The use of mesenchymal stem cells for cartilage repair and regeneration: a systematic review.

    Get PDF
    BACKGROUND: The management of articular cartilage defects presents many clinical challenges due to its avascular, aneural and alymphatic nature. Bone marrow stimulation techniques, such as microfracture, are the most frequently used method in clinical practice however the resulting mixed fibrocartilage tissue which is inferior to native hyaline cartilage. Other methods have shown promise but are far from perfect. There is an unmet need and growing interest in regenerative medicine and tissue engineering to improve the outcome for patients requiring cartilage repair. Many published reviews on cartilage repair only list human clinical trials, underestimating the wealth of basic sciences and animal studies that are precursors to future research. We therefore set out to perform a systematic review of the literature to assess the translation of stem cell therapy to explore what research had been carried out at each of the stages of translation from bench-top (in vitro), animal (pre-clinical) and human studies (clinical) and assemble an evidence-based cascade for the responsible introduction of stem cell therapy for cartilage defects. This review was conducted in accordance to PRISMA guidelines using CINHAL, MEDLINE, EMBASE, Scopus and Web of Knowledge databases from 1st January 1900 to 30th June 2015. In total, there were 2880 studies identified of which 252 studies were included for analysis (100 articles for in vitro studies, 111 studies for animal studies; and 31 studies for human studies). There was a huge variance in cell source in pre-clinical studies both of terms of animal used, location of harvest (fat, marrow, blood or synovium) and allogeneicity. The use of scaffolds, growth factors, number of cell passages and number of cells used was hugely heterogeneous. SHORT CONCLUSIONS: This review offers a comprehensive assessment of the evidence behind the translation of basic science to the clinical practice of cartilage repair. It has revealed a lack of connectivity between the in vitro, pre-clinical and human data and a patchwork quilt of synergistic evidence. Drivers for progress in this space are largely driven by patient demand, surgeon inquisition and a regulatory framework that is learning at the same pace as new developments take place

    Die Entwicklung des Body Mass Index bei Patienten mit Hüfttotalendoprothese

    No full text

    Proposal for a histopathological consensus classification of the periprosthetic interface membrane

    No full text
    AIMS: The introduction of clearly defined histopathological criteria for a standardised evaluation of the periprosthetic membrane, which can appear in cases of total joint arthroplasty revision surgery. METHODS: Based on histomorphological criteria, four types of periprosthetic membrane were defined: wear particle induced type (detection of foreign body particles; macrophages and multinucleated giant cells occupy at least 20% of the area; type I); infectious type (granulation tissue with neutrophilic granulocytes, plasma cells and few, if any, wear particles; type II); combined type (aspects of type I and type II occur simultaneously; type III); and indeterminate type (neither criteria for type I nor type II are fulfilled; type IV). The periprosthetic membranes of 370 patients (217 women, 153 men; mean age 67.6 years, mean period until revision surgery 7.4 years) were analysed according to the defined criteria. RESULTS: Frequency of histopathological membrane types was: type I 54.3%, type II 19.7%, type III 5.4%, type IV 15.4%, and not assessable 5.1%. The mean period between primary arthroplasty and revision surgery was 10.1 years for type I, 3.2 years for type II, 4.5 years for type III and 5.4 years for type IV. The correlation between histopathological and microbiological diagnosis was high (89.7%), and the inter‐observer reproducibility sufficient (85%). CONCLUSION: The classification proposed enables standardised typing of periprosthetic membranes and may serve as a tool for further research on the pathogenesis of the loosening of total joint replacement. The study highlights the importance of non‐infectious, non‐particle induced loosening of prosthetic devices in orthopaedic surgery (membrane type IV), which was observed in 15.4% of patients

    Long-term results of the Wagner cone prosthesis

    No full text
    The Wagner cone prosthesis is indicated in uncemented total hip replacement of cases with cylinder-shaped femurs, deformed femurs, femurs with increased antetorsion, and in conditions of intramedullary bony scar tissue after previous osteotomies. The objective of this study is to present long-term results. From January 1, 1993 to December 31, 1995, 132 implantations were made with the Wagner cone prosthesis. We report the clinical and radiographic results of 94 cone prostheses with a mean observation period of 11.5 years. The Merle d’Aubigné score improved from a preoperative mean value of 8.8 to a postoperative mean of 16.3. The radiographic evaluation revealed 32 cases with cortical hypertrophy, 73 cases with atrophy of the proximal femur, and 18 cases with complete pedestal formation. Radiolucencies over Gruen zones 1 and 7 occurred in 42 cases; only zone 1 was affected in 24 cases. Complications included three deep infections, three acetabular revisions, five total joint revisions, one recurrent luxation, and three heterotopic ossifications. In spite of the fact that the examined cohort often included patients who had undergone multiple previous operations (a maximum of six) of the proximal femur or the acetabulum, the long-term results of the Wagner cone prostheses were very promising