374 research outputs found

    Generalized Langevin equation with shear flow and its fluctuation-dissipation theorems derived from a Caldeira-Leggett Hamiltonian

    Full text link
    We provide a first-principles derivation of the Langevin equation with shear flow and its corresponding fluctuation-dissipation theorems. Shear flow of simple fluids has been widely investigated by numerical simulations. Most studies postulate a Markovian Langevin equation with a simple shear drag term \`a la Stokes. However, this choice has never been justified from first principles. We start from a particle-bath system described by a classical Caldeira-Leggett Hamiltonian modified by adding a term proportional to the strain-rate tensor according to Hoover's DOLLS method, and we derive a generalized Langevin equation for the sheared system. We then compute, analytically, the noise time-correlation functions in different regimes. Based on the intensity of the shear-rate, we can distinguish between close-to-equilibrium and far-from-equilibrium states. According to the results presented here, the standard, simple and Markovian form of the Langevin equation with shear flow postulated in the literature is valid only in the limit of extremely weak shear rates compared to the effective vibrational temperature of the bath. For even marginally higher shear rates, the (generalized) Langevin equation is strongly non-Markovian and non-trivial fluctuation-dissipation theorems are derived

    Rate-Control or Rhythm-Contol: Where do we stand?

    Get PDF
    Atrial fibrillation is the most common sustained rhythm disturbance and its prevalence is increasing worldwide due to the progressive aging of the population. Current guidelines clearly depict the gold standard management of acute symptomatic atrial fibrillation but the best-long term approach for first or recurrent atrial fibrillation is still debated with regard to quality of life, risk of new hospitalizations, and possible disabling complications, such as thromboembolic stroke, major bleeds and death. Some authors propose that regaining sinus rhythm in all cases, thus re-establishing a physiologic cardiac function not requiring a prolonged antithrombotic therapy, avoids the threat of intracranial or extracranial haemorrhages due to Vitamin K antagonists or aspirin. On the contrary, advocates of a rate control approach with an accurate antithrombotic prophylaxis propose that such a strategy may avoid the risk of cardiovascular and non cardiovascular side effects related to antiarrhythmic drugs. This review aims to explore the state of our knowledge in order to summarize evidences and issues that need to be furthermore clarified

    Rate-Control or Rhythm-Control: Where do we stand?

    Get PDF
    Atrial fibrillation is the most common sustained rhythm disturbance and its prevalence is increasing worldwide due to the progressive aging of the population. Current guidelines clearly depict the gold standard management of acute symptomatic atrial fibrillation but the best-long term approach for first or recurrent atrial fibrillation is still debated with regard to quality of life, risk of new hospitalizations, and possible disabling complications, such as thromboembolic stroke, major bleeds and death. Some authors propose that regaining sinus rhythm in all cases, thus re-establishing a physiologic cardiac function not requiring a prolonged antithrombotic therapy, avoids the threat of intracranial or extracranial haemorrhages due to Vitamin K antagonists or aspirin. On the contrary, advocates of a rate control approach with an accurate antithrombotic prophylaxis propose that such a strategy may avoid the risk of cardiovascular and non cardiovascular side effects related to antiarrhythmic drugs. This review aims to explore the state of our knowledge in order to summarize evidences and issues that need to be furthermore clarified

    Cardiac Pacemaker Battery Discharge After External Electrical Cardioversion for Broad QRS Complex Tachycardia

    Get PDF
    External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected

    Cardiac pacemaker battery discharge after external electrical cardioversion for broad QRS Complex Tachycardia

    Get PDF
    External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected

    Should we perform systematic electrophysiological study in Steinert's disease?

    Get PDF
    Myotonic dystrophy type 1 (Steinert's disease) is a multisystem disorder with autosomal dominant inheritance. This disease is associated with the presence of an abnormal expansion of a cytosine thymine-guanine (CTG) trinucleotide repeat on chromosome 19q13.3. Because of rhythmic complications, the place for systematic electrophysiological study (EPS) has to be discussed

    Long-term clinical impact of permanent pacemaker implantation in patients undergoing transcatheter aortic valve implantation: a systematic review and meta-analysis

    Get PDF
    AIMS: The aims of this study is to assess by an updated meta-analysis the clinical outcomes related to permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) at long-term (≥12 months) follow-up (LTF). METHODS AND RESULTS: A comprehensive literature research was performed on PubMed and EMBASE. The primary endpoint was all-cause death. Secondary endpoints were rehospitalization for heart failure, stroke, and myocardial infarction. A subgroup analysis was performed according to the Society of Thoracic Surgeon-Predicted Risk of Mortality (STS-PROM) score. This study is registered with PROSPERO (CRD42021243301). A total of 51 069 patients undergoing TAVI from 31 observational studies were included. The mean duration of follow-up was 22 months. At LTF, PPI post-TAVI was associated with a higher risk of all-cause death [risk ratio (RR) 1.18, 95% confidence interval (CI) 1.10-1.25; P < 0.001] and rehospitalization for heart failure (RR 1.32, 95% CI 1.13-1.52; P < 0.001). In contrast, the risks of stroke and myocardial infarction were not affected. Among the 20 studies that reported procedural risk, the association between PPI and all-cause death risk at LTF was statistically significant only in studies enrolling patients with high STS-PROM score (RR 1.25, 95% CI 1.12-1.40), although there was a similar tendency of the results in those at medium and low risk. CONCLUSION: Patients necessitating PPI after TAVI have a higher long-term risk of all-cause death and rehospitalization for heart failure as compared to those who do not receive PPI

    Automated conduction velocity estimation based on isochronal activation of heart chambers

    Get PDF
    Background Spatial differences in conduction velocity (CV) are critical for cardiac arrhythmias induction. We propose a method for an automated CV calculation to identify areas of slower conduction during cardiac arrhythmias and sinus rhythm.Methods Color-coded representations of the isochronal activation map using data coming from the RHYTHMIA (TM) Mapping System were reproduced by applying a temporal isochronal window at 20 ms. Geodesic distances of the 3D mesh were calculated using an algorithm selecting the minimum distance pathway (MDP). The CV estimation was performed considering points on the boundary of two spatially and temporally adjacent isochrones. For each of the boundary points of a given isochrone, the nearest boundary point of the consecutive isochrone was chosen, the MDP was evaluated, and a map of CV was created. The proposed method has been applied to a population of 29 patients.Results In all cases of perimitral atrial flutter (16 pts out of 29 (55%)), areas with significantly low CV (< 30 cm/s) were found. Half of the cases present regions with low CV located in the anterior wall. No case with low CV at the so-called LA isthmus was observed. Right atrial maps during common atrial flutters showed low CV areas mainly located in the inferior inter-atrial septum. No areas of low CV were observed in subjects without a history of atrial arrhythmia while pts affected by paroxysmal AF showed areas with a limited extension of low CV.Conclusions The proposed software for automated CV estimation allows the identification of low CV areas, potentially helping electrophysiologists to plan the ablation strategy

    Coexistence of Vagus Nerve Stimulation and Epicardial Implantable Cardioverter-Defibrillator System, Possible Interference: A Case Report and Systematic Review of the Literature

    Get PDF
    Vagus nerve stimulation (VNS) is an effective treatment for drug-resistant epilepsies in adults [1] and children [2]. Although VNS is generally well tolerated, rare cases of severe bradycardia..
    corecore