37 research outputs found

    Impact of optimized clopidogrel 150 mg and atorvastatin 80 mg treatment to control neointimal hyperplasia after PCI with bare metal stent: an intravascular ultrasound study

    No full text
    Fundamentos: O implante de stents coronários constitui-se na técnica mais prevalente de revascularização percutânea, em especial pela prevenção da reestenose, quando comparado às intervenções com o balão. No entanto, a reestenose intra-stent, que ocorre em cerca de 25% dos casos, restringe os seus benefícios clínicos e econômicos tardios. Demonstrou-se que a hiperplasia neo-intimal decorrente da reação da parede vascular causada pelo implante do stent, é responsável pelas recidivas. Interroga-se se um protocolo de medicamentos contemplando doses máximas de manutenção de clopidogrel e atorvastatina poderia reduzir a hiperplasia neo-intimal e a reestenose. Objetivos: O objetivo primário foi aferir se esta associação de medicamentos reduziria o volume de hiperplasia neo-intimal (35% ou mais), expressa pela obstrução volumétrica da luz, mensurada pelo ultrassom intracoronário, 12 meses após a intervenção. Os objetivos secundários foram: os resultados da angiografia quantitativa e os eventos cardíacos adversos maiores (óbito, infarto e revascularização do vaso-alvo). Casuística e métodos: Foram incluídos casos eletivos e com lesões primárias nas artérias naturais. Os pacientes foram tratados com stents não farmacológicos e randomizados em dois grupos: A, com 50 pacientes medicados com doses máximas de clopidogrel e atorvastatina; e grupo B com 50 casos, medicados com 75mg de clopidogrel e doses de sinvastatina rotineiramente prescritas para obtenção das metas recomendadas para controle lipídico. Resultados: Ambos os grupos não apresentaram diferenças significantes em relação às características clínicas, angiográficas e técnicas, com exceção do diabetes, mais comum em A (36% vs 16%; p=0,02). Aos 12 meses de evolução, observaram-se eventos cardíacos maiores (12% versus 18%; p = 0,56) e revascularização do vaso-alvo (4% versus 2%; p>0,99) sem diferença significante. Nova angiografia coronária foi obtida em 98% dos casos dos dois grupos, observando-se taxa de reestenose de 8,1% e 8,2% nos grupos A e B (p>0,99). A perda tardia da luz arterial foi semelhante [0,9 mm (DP 0,5 mm) versus 1,1 mm (DP 0,7 mm); p = 0,22], o mesmo acontecendo com o diâmetro mínimo da luz [2,2 mm (DP 0,6 mm) versus 1,9 mm (DP 0,6 mm); p = 0,12]. Realizou-se ultrassom intracoronário em 98% dos pacientes de ambos os grupos, observando-se obstrução do volume da luz de 36,3% (DP 10,3%) no grupo A e de 40,1% (DP 10,9%) no grupo B (p = 0,14). Conclusões: Os resultados deste estudo demonstram que: 1) a terapêutica adjunta utilizando doses máximas de clopidogrel 150 mg/dia e atorvastatina 80 mg/dia não reduz o volume de hiperplasia neo-intimal, expressa pela obstrução volumétrica da luz; 2) as variáveis da angiografia quantitativa e os eventos cardíacos adversos maiores não mostraram diferenças significativas entre os dois grupos.Coronary stent implantation is the current technique of choice in patients undergoing percutaneous intervention. They effectively reduce acute occlusion and restenosis even in complex lesions. However, instent restenosis occurs in up to 25% of the treated cases and there are several theories elaborating the possible relation between coronary artery thrombosis and inflammation to neointimal proliferation and the mechanism of obstruction recurrence. There are questions whether an optimized medical treatment based on maximum doses of Clopidogrel and Atorvastatin could limit neointimal hyperplasia and restenosis. Objectives: Primary endpoint was to assess the efficacy of this scheme in reducing neointimal hyperplasia volume (XX% or more), according to intravascular ultrasound measurements, 12 months after the index intervention. Secondary endpoints were quantitative angiography measurements and major adverse cardiac events (death, myocardial infarction and target vessel revascularization). Methods: We included patients with de novo lesions undergoing elective implantation of uncoated stents. Patients were divided according to the drug regimen into Group A - 50 patients receiving maximal atorvastatin and clopidogrel doses; and Group B - 50 cases treated with standard clopidogrel and simvastatin doses. Results: Groups were similar concerning clinical and angiographic characteristics, except for diabetes, more frequent in Group A (36% vs 16%, p = 0.02). At the end of 12 months major cardiac events (12% versus 18%, p = 0.56) and target vessel revascularization (4% versus 2%, p> 0.99) did not show differences between groups. Coronary angiography was obtained in 98% of the cases and the restenosis rate was 8.1% (A group) and 8,2% (B group) (p> 0.99). Late luminal loss was similar [0.9 mm (SD 0.5 mm) versus 1.1 mm (SD 0.7 mm), p = 0.22], as well as the minimum lumen diameter [2.2 mm (SD 0.6 mm) versus 1.9 mm (SD 0.6 mm), p = 0.12]. IVUS was done in 98% of patients in both groups, and the volume of neointimal hyperplasia was not significantly different in both groups [61.8 mm 3 (SD 35.4 mm3) mm3 versus 66.3 (SD 31.6 mm3), p = 0.58]. Luminal volume obstruction was 36.3% (SD 10.3%) in group A and 40.1% (SD 10.9%) in group B (p = 0.14). Conclusions: According to our results we may conclude that: 1) the therapeutic regimen using maximum doses of atorvastatin and clopidogrel did not reduce the volume of neointimal hyperplasia, 2) restenosis rate, quantitative angiography results and the rate of major adverse cardiac events were not affected by the treatment regimen

    Manage of crop load to improve fruit quality in plums

    No full text
    Abstract The crop load of European plums must be adjusted to achieve high quality with adequate size and skin color in order to attend market requirements. The present study had the objective to investigate the effects of chemical and mechanical thinning, applied isolated and in combination of both, at different phenological stages of Katinka plum growing in Southern Germany. The following thinners were tested: mechanical thinning, chemical thinning with Ammoniumthiosulfate - ATS, Ethephon, Prohexadione-Calcium and Gibberellin. Mechanical thinning treatment isolated or associated with ATS. Significantly increased fruit drop and reduced the yield. It also, increased fruit size and fruit weight when compared to the control plants. Also Ethephon increased fruit drop and fruit size when compared to the control plants. Among to other chemical treatments, no positive effects were observed for fruit thinning when compared to the control plants

    Qualidade da maçã "Gala" armazenada em atmosfera controlada associada à absorção e ao controle da síntese e da ação do etileno Quality of 'Gala' apples stored in controlled atmosphere associated with ethylene absorption and control of its syntheses and action

    No full text
    Este trabalho teve por objetivo avaliar o efeito da inibição da biossíntese de etileno no período pré-colheita e o efeito da inibição da ação ou da absorção do etileno durante o armazenamento em atmosfera controlada (AC; 1,2kPa de O2 + 2,5kPa de CO2 a 0°C) sobre a qualidade de maçãs cv. "Gala". Além disso, avaliou-se também o efeito combinado desses tratamentos. Os tratamentos avaliados foram: (1) armazenamento em AC (controle); (2) aplicação pré-colheita de AVG; (3) AVG + aplicação pós-colheita de 1-MCP; (4) aplicação de 1-MCP; (5) AVG + absorção do etileno durante todo o período de armazenamento; e (6) absorção de etileno. Após oito meses de armazenamento mais sete dias a 20°C, os frutos tratados com AVG apresentaram menor atividade da ACC oxidase. A combinação de AVG + 1-MCP ou AVG + absorção de etileno mantiveram menor produção de etileno até cinco dias de vida de prateleira a 20°C. Além disso, a firmeza da polpa dos frutos submetidos a esses tratamentos combinados manteve-se mais elevada. A cor de fundo da epiderme manteve-se mais verde nos frutos tratados com AVG, independente do tratamento em pós-colheita, demonstrando que a modificação da coloração da epiderme é mais afetada pelo etileno produzido ainda na pré-colheita. Portanto, conclui-se que a aplicação em pré-colheita de AVG associada com a absorção do etileno durante o armazenamento é mais eficiente no controle da maturação de maçãs "Gala", no entanto, a aplicação pré-colheita de AVG combinada com a aplicação pós-colheita de 1-MCP também é eficiente.This research aimed to evaluate the effect of inhibition the ethylene biosynthesis at the pre-harvest stage, the ethylene action and the absorption from the controlled atmosphere storage room on the quality of 'Gala' apples. The experimental design was entirely randomized, with four replicates and the experimental unit composed by 25 fruits. The treatments were: (1) CA storage only (control); (2) pre-harvest application of AVG; (3) AVG + postharvest treatment with 1-MCP; (4) 1-MCP; (5) AVG + ethylene absorption during the storage period; and (6) ethylene absorption. Fruit quality was evaluated after 8 months of storage (CA; 1.2 kPa O2 + 2.5 kPa CO2 at 0°C) and after 7 days at 20°C. AVG-treated fruits showed lower ACC oxidase activity. AVG + 1-MCP and AVG + ethylene absorption decreased the ethylene production until 5 days of shelf-life and maintained higher flesh firmness. AVG-treated fruits had greener skin color, independently of the postharvest handling, showing that the change in the skin background colour is highly related to the pre-harvest ethylene production. The conclusion of this research is that the pre-harvest treatment of fruits with AVG associated with the absorption of ethylene during the storage is more efficient for controlling the ripening process in 'Gala' apples, nevertheless the application of AVG associated with postharvest application of 1-MCP is also efficient
    corecore